S L, Z Thread AC Flange DC Note) Surge voltage suppressor is attached to the lead wire.
(inch) Connection thread R Model H (Width across flats) L2 A M Min. port size Note) Weight (g) D1 D2 L1 Applicable tubing KQ2W05-02S KQ2W05-01S 1 8 19 41 20 45 69 30 47 74 69 10 38 44 40 43.5 11.4 10 19.5 16.5 3.5 3 16 1 4 14 1 8 1 4 KQ2W07-01S 40.5 43 10 4.6 KQ2W07-02S KQ2W07-03S KQ2W09-01S KQ2W09-02S KQ2W09-03S KQ2W11-02S 1 4 13.2 10 20.5 46.5 48.5 43.5 49.5 51.5 56 47 49 47 51 53 59 14
L A D KRH06-02S KRH06-01S 1 8 10.8 15.8 27.8 21.9 19.9 26.9 20.3 12 20.5 24.5 1 4 18.5 19 19 5.7 6 14 17 15.5 25 3 8 1 8 KRH06-03S 26 18.0 KRH08-01S KRH08-02S KRH08-03S KRH10-01S KRH10-02S KRH10-03S 30 28.5 25.5 32 35.5 31 29 36.5 35 32 Reference dimensions after R(PT) thread installation. 14 1 4 3 8 1 8 1 4 3 8 22.5 19 28 29.5 24.5 17 8 20.5 17 17 20.8 31.3 29.5 10 23 1 2 KRH10-04S 21 54.3
Thread: R, Seal: S (Seal), Options: 6P (6 + P)
Thread: R, Seal: S (Seal), Options: LP (L + P)
Thread: R, Seal: S (Seal), Options: P (Scale Plate Pressure Unit: Both MPa and psi)
Thread: R, Seal: S (Seal), Options: 6PZ (6 + P + Z)
Thread: R, Seal: S (Seal), Options: L (3m Lead Wire Length)
Thread: R, Seal: S (Seal), Options: 6L (6 + L)
Thread: R, Seal: S (Seal), Options: 6 (0.1 to 0.6MPa Set Pressure Range)
Thread: R, Seal: S (Seal), Options: 6Z (6 + Z)
Thread: R, Seal: S (Seal), Options: 6LP (6 + L + P)
Thread: R, Seal: S (Seal), Options: PZ (P + Z)
Type: Pressure Switch, Fluid Type: Air, Sensor, Monitor Structure: [Separate Type Connector Connection] Separated sensor, Output Method: Switch, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [Rc (R)] R, Plumbing Thread Nominal: [1/8] 1/8, Fluid Characteristics: Inert, Pressure Resistance(MPa): 1, Operating Temperature Range(°C): -5~60, Number of Inputs: 1, Number of Outputs
Type: Pressure Switch, Fluid Type: Air, Sensor, Monitor Structure: [Separate Type Connector Connection] Separated sensor, Output Method: Switch, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [Rc (R)] R, Plumbing Thread Nominal: [1/8] 1/8, Fluid Characteristics: Inert, Pressure Resistance(MPa): 1, Operating Temperature Range(°C): -5~60, Number of Inputs: 1, Number of Outputs
Type: Pressure Switch, Fluid Type: Air, Sensor, Monitor Structure: [Separate Type Connector Connection] Separated sensor, Output Method: Switch, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [Rc (R)] R, Plumbing Thread Nominal: [1/8] 1/8, Fluid Characteristics: Inert, Pressure Resistance(MPa): 1, Operating Temperature Range(°C): -5~60, Number of Inputs: 1, Number of Outputs
Thread: R, Seal: Seal, Options: Scale Plate Pressure Unit: Both MPa and psi