orientation Ceiling m Wall m Vertical m Note) Static load m Horizontal m M M m x g x X m x g x X m x g x Z M Static moment z y Y m x g x Y m x g x Y m x g x Z M Z m x g x X m x g x Y m x g M Note) m is a mass movable by thrust.
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: D [Panel Mount Adapter + Front Protection Cover, (ZS-46-D)]
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: D [Panel Mount Adapter + Front Protection Cover, (ZS-46-D)], Operation Manual: -
Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter + Front Protection Cover, Operation Manual: -
Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter + Front Protection Cover, Operation Manual: -
Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter + Front Protection Cover, Operation Manual: -
Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: D (Panel Mount Adapter + Front Protection Cover)
Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: D (Panel Mount Adapter + Front Protection Cover)
Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: D (Panel Mount Adapter + Front Protection Cover)
5 2r2 = m 4 r2 CRQ2 = m 12 a2 + b2 MSQ MRQ 10.
Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: SI Unit Only, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8)
Standard type For 90 For 180 Positioning pin hole Positioning pin hole Counter-clockwise 3 3 A port A port A port 3 22.5 3 22.5 84 e 96 ng e 3 ra ng on ra ti B port n ta 3 90 tio 4 ro 7 ta m 1 Clockwise ro e e u s i g m w 3 m 6 k C n c l o ni a u 8 r Mi im 3 n 1 o ti e ax ta ng ro m M u ra m ni Mi 180 n tio e C s ta l i o w c k ro m mu xi Ma Positioning pin hole Positioning pin hole Position
Mounting orientation and static moment Mounting orientation Static load Horizontal mounting Ceiling mounting Wall mounting Vertical mounting Bore size (mm) A [mm] 6 10 15 20 25 32 40 m m x g x x m x g x y 19 21 25 27 33 40 49 m x g x x m x g x y m x g x (z + A) m x g x x m x g x (z + A) m x g x y M1 M2 M3 Static moment A: Distance between the center of the guide shaft and the upper surface
Applicable pad 04U/06U/08U Applicable pad 10U/16U Applicable pad 25U/32U Applicable pad 40U/50U 4.9 30 R 30 R R 25 30 R R R R 10.5 9.5 2 8 9 25 R 2 0.5 6 7 7 8 R R R R R R 45 45 45 2.7 1 R R 2.5 4.5 5 6.6 R 2.5 3.8 4.9 3.5 5 6 7.9 R 4.5 8 9 11.7 11.7 Note) R part has to be smooth with no corners.
Applicable pad 04U/06U/08U Applicable pad 10U/16U Applicable pad 25U/32U Applicable pad 40U/50U 4.9 30 R 30 R R 25 30 R R R R 10.5 9.5 2 8 9 25 R 2 0.5 6 7 7 8 R R R R R R 45 45 45 2.7 1 R R 2.5 4.5 5 6.6 R 2.5 3.8 4.9 3.5 5 6 7.9 R 4.5 8 9 11.7 11.7 Note) R part has to be smooth with no corners.
Port size ASV Model M3 x 0.5 ASV120F-M3 0.3 0.3 AK M5 x 0.8 ASV220F-M5 1.3 1.3 R 1/8 ASV310F-01 8 7 ASS R 1/4 ASV310F-02 8 7 R 1/8 ASV410F-01 14 13.5 ASR R 1/4 ASV410F-02 14 13.5 R 3/8 ASV410F-03 14 13.5 ASF R 1/4 ASV510F-02 27 23 R 3/8 ASV510F-03 29 27 R 1/2 ASV510F-04 29 27 10-32 UNF ASV220F-U10/32 1.3 1.3 NPT 1/8 ASV310F-N01 8 7 NPT 1/4 ASV310F-N02 8 7 NPT 1/8 ASV410F-N01 14 13.5 NPT 1
Applicable pad 04U/06U/08U Applicable pad 10U/16U Applicable pad 25U/32U Applicable pad 40U/50U 4.9 30 R 30 R R 25 30 R R R R 10.5 9.5 2 8 9 25 R 2 0.5 6 7 7 8 R R R R R R 45 45 45 2.7 1 R R 2.5 4.5 5 6.6 R 2.5 3.8 4.9 3.5 5 6 7.9 R 4.5 8 9 11.7 11.7 Note) R part has to be smooth with no corners.
t) 1.79 r45.51 1 . 1 4 (29) 0.31 (8) Millimeters in Parentheses NVMl20-N01-05 130-N01-05 M 1 4 X P I EXH $o I I M A X , G z-Nm h Panel Mounting r \-r,tr, 5.07 lbs (2.3 kg ) P T 0 079 in (2mm) O T 0.059 in (1 5mm) T,T. 0 138 in (3.5mm) F . O F 5.07 lbs. (2 3 kg.)