or less Ionic state silica (SiO2) [mg/L] 50 or less Iron (Fe) [mg/L] 1.0 or less Copper (Cu) [mg/L] 0.3 or less Sulfide ion (S2) [mg/L] Should not be detected Ammonium ion (NH4+) [mg/L] 1.0 or less Residual chlorine (Cl) [mg/L] 0.3 or less Free carbon (CO2) [mg/L] 4.0 or less Reference item 6.

Acid consumption amount (at pH4.8) [mg/L] 100 or less v Total hardness [mg/L] 200 or less v Calcium hardness (CaCO3) [mg/L] 150 or less v Ionic state silica (SiO2) [mg/L] 50 or less v Iron (Fe) [mg/L] 1.0 or less v v Copper (Cu) [mg/L] 0.3 or less v Sulfide ion (S2) [mg/L] Should not be detected v Ammonium ion (NH4+) [mg/L] 1.0 or less v Residual chlorine (Cl) [mg/L] 0.3 or less v Free carbon

Bracket C MPa ISE20C(H) ISE20C: 0.050 MPa/ZSE20C: 5.1 kPa/ ZSE20CF: 5.0 kPa/ISE20CH: 0.100 MPa "Nil" or M Hysteresis Self tapping screws: Nominal size 3 x 8L kPa ZSE20C(F) Self tapping screws: Nominal size 3 x 10L Safety Instructions Bracket A ISE20C(H) Delay time 1.5 ms or less psi P ZSE20C(F) Display color OUT1 ON: Green/OUT1 OFF: Red : Arbitrary display These safety instructions are intended

Secondary battery capability is achieved by providing removing the bracket munting inserts found on the ISE20C(H).  25A-ISE20C(H) is UL/CSA, CE and RoHS compliant, with an IP65 enclosure rating.

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)

This is a legacy product, and replaced byISE20C-X-N02L-W, SWITCH ASSEMBLY, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, DB, ISE40/50/60 1/4 NPT VERSION, .44092 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureWetted parts materialApplicable fluidPort sizePower supply voltageCurrent consumption--Switch outputRepeatabilityHysteresisAnalog outputAuto-shift inputDisplayDisplay

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter + Front

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket C, Operation Manual

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: F (Panel Mount

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A3 (Bracket C

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -