Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: K (Operation Manual + Calibration Certificate)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: K (Operation Manual + Calibration Certificate)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: B (Bracket B)
Pressure Range: ISE71 (0 to 1.6 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
Capacity H O W T O O R D E R S E R I E S (N)AK T E C H N I C A L SPECIFICATIONS B O D Y S I Z E .P O RT . . .E F F E C T I V E S I Z E NPT . . .O R I F I C E* NAQ1500-M5 .M5 . . .2.8 NAQ1510-N01...1 8 . . . .5.8 NAQ2000-N01...1 8 . . . .25 NAQ2000-N02...1 4 . . . .40 NAQ3000-N02...1 4 . . . .42 NAQ3000-N03...3 8 . . . .70 NAQ5000-N04...1 2 . . . .115 NAQ5000-N06...3 4 . . . .180 Fluid Air
FU) (mm) AA AB A AV AW AX AY BA BB BC BD BE CB D DD DE DF DG FA FB FC FD H J JA JB Size 70 100 200 90 92 84 42 25.5 27 8 17 75 44.5 110 57 36 88h9 90h9 46H9 16 22H9 12.5 5 3.5 9 22 10.4 17.5 10.5 100h9 101 102 95 50 29.5 27 8 17 85 50.5 130 66 42 98h9 56H9 19 24H9 14.5 6 3.5 12 27 10.4 17.5 10.5 116h9 118h9 119 120 113 60 36.5 36 10 24 103 65.5 150 80 57 64H9 24 32H9 16.5 9 5.5 15 32 14.2
FU) (mm) AA AB A AV AW AX AY BA BB BC BD BE CB D DD DE DF DG FA FB FC FD H J JA JB Size 70 100 200 90 92 84 42 25.5 27 8 17 75 44.5 110 57 36 88h9 90h9 46H9 16 22H9 12.5 5 3.5 9 22 10.4 17.5 10.5 101 102 100h9 95 50 29.5 27 8 17 85 50.5 130 66 42 98h9 56H9 19 24H9 14.5 6 3.5 12 27 10.4 17.5 10.5 119 120 116h9 118h9 113 60 36.5 36 10 24 103 65.5 150 80 57 64H9 24 32H9 16.5 9 5.5 15 32 14.2
FU) (mm) AA AB A AV AW AX AY BA BB BC BD BE CB D DD DE DF DG FA FB FC FD H J JA JB Size 70 100 200 90 92 84 42 25.5 27 8 17 75 44.5 110 57 36 88h9 90h9 46H9 16 22H9 12.5 5 3.5 9 22 10.4 17.5 10.5 101 102 100h9 95 50 29.5 27 8 17 85 50.5 130 66 42 98h9 56H9 19 24H9 14.5 6 3.5 12 27 10.4 17.5 10.5 119 120 116h9 118h9 113 60 36.5 36 10 24 103 65.5 150 80 57 64H9 24 32H9 16.5 9 5.5 15 32 14.2
) 16-2-51 8 Series ISE70/75/75H Pressure Switch Precautions Be sure to read before handling.
6 i D249 Series CRQ2 Dimensions Size 10/15 3H9 effective depth 2 0.6 TA 30 BU 2 x M5 x 0.8 through (Opposite side 7.6 counterbore depth 4.2) B With double shaft DD W D 2 10 2 x M5 x 0.8 (Port) H Q (US) (UW) BD BC M ab BA BA BB D (AU) Max.
P:psi, K:KPa, kgf:kgf/cm2, M:MPa, b:bar W I R I N G E X A M P L E S O F R E L AY A L A R M D I S P L AY When the pressure reaches within +10% of the value preset by a pressure switch value, the LCD lights to show that the pressure is approaching the preset value. When the line pressure becomes lower than the preset pressure, the LED (red) of (2) ALM lights and the switch turns on.
) 16-2-51 8 Series ISE70/75/75H Pressure Switch Precautions Be sure to read before handling.
lBore size slainlss steel D slon rod Adjustable stroke Exrend'" -xc9 Adjustable slrokeRelracl^^ -xc10 Dul slfokeDouble rod" 25 25frfr i9)nuto switcrr See cata og E2161or ava ab e auto swlclres -xcl2 Aulo swilch rai mounlinq 63 63mn a0 1 m -xc36 -xc37 -xc42 (Ocytinaer strote (mm) "see calalog E21 6 for 'How 1o order' nformal on r o ' Not ava ab e lor boe s 4 o80 Norel S nq e acrng.6labe 20
(Mounting thread) Note) If the fitting attached to the port interferes with the auto switch, please use the extension fitting assembly supplied with the air gripper. 4 x AA thread depth AB (Mounting thread) Prepared hole diameter AC through (Mounting hole) Note) AD depth AE AF depth AG S H When open AS When closed AR When closed AT M T D P B R N G Q F E C A 2 x AH thread depth AJ (Mounting
5 y q r 312 CRQ2X Series Low-Speed Compact Rotary Actuator Rack & Pinion Type Dimensions Size 10/15 3H9 effective depth 2 CRB2 TA 0.6 CRB1 30 MSU BU CRJ CRA1 2 x M5 x 0.8 through (Opposite side 7.6 counterbore depth 4.2) B CRQ2 MSQ With double shaft DD W D MSZ CRQ2X MSQX CRQ2X MSQX H 2 10 2 x M5 x 0.8 (Port) MRQ (US) M (UW) BD Q BC ab BA BB BA D (AU) Max.
(17) 0 R www.smcworld.com 0x0012 (18) 0 R ISE70-02-L2 0x0013 (19) 0 R ID ISE70-02-L2 0x0014 (20) 0 R Pressure sensor 8 0x0015 (21) 0 R No.
ISE70 0 to 1 MPa ISE71 0 to 1.6 MPa Symbol Description Nil Operation manual Y None K Operation manual + Calibration certificate Piping specification Symbol Description 02 Rc1/4 N02 NPT1/4 F02 G1/4*1 T Calibration certificate Option 2 Symbol Description Nil None *1 ISO 1179-1 compliant Output specification*1 A Bracket A (Interchangeable with ISE70) Symbol Description B Bracket B L2 IO-Link