Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: None, Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: B (Bracket B)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: K (Operation Manual + Calibration Certificate)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: B (Bracket B)
Pressure Range: ISE71 (0 to 1.6 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
) 16-2-51 8 Series ISE70/75/75H Pressure Switch Precautions Be sure to read before handling.
) 16-2-51 8 Series ISE70/75/75H Pressure Switch Precautions Be sure to read before handling.
(17) 0 R www.smcworld.com 0x0012 (18) 0 R ISE70-02-L2 0x0013 (19) 0 R ID ISE70-02-L2 0x0014 (20) 0 R Pressure sensor 8 0x0015 (21) 0 R No.
ISE70 0 to 1 MPa ISE71 0 to 1.6 MPa Symbol Description Nil Operation manual Y None K Operation manual + Calibration certificate Piping specification Symbol Description 02 Rc1/4 N02 NPT1/4 F02 G1/4*1 T Calibration certificate Option 2 Symbol Description Nil None *1 ISO 1179-1 compliant Output specification*1 A Bracket A (Interchangeable with ISE70) Symbol Description B Bracket B L2 IO-Link
www.stevenengineering.com I 5.16 AIR PREPARATION MODULAR TYPE ACCESSORIES END BLOCK ADAPTOR Port Sizes: M5 ~ 1Rc Allows for easy installation and maintenance H O W T O O R D E R P I P I N G A D A P T O R E10-M5 1000 S E R I E S E20-N01 2000 S E R I E S E20-N02 2000 S E R I E S E20-N03 2000 S E R I E S E30-N02 3000 S E R I E S E30-N03 3000 S E R I E S E30-N04 3000 S E R I E S E40-N03 4000
/ISE75(H) ISE70/ISE75(H) ISE70/ISE75(H) ISE70/ISE75(H) () 1 ON ON OFF Yes No 2 OFF ON 1 OFF 3 4 5 -26No.PS-OMH0002CN-D 6 Yes No 7 7 8 9 10 11 12 13 14 15 -27No.PS-OMH0002CN-D No.
Bracket A Bracket B [F 0] Display units, switch output specifications and diagnostic information selection function ISE70(G): 0.500 MPa/ISE71: 0.800 MPa/ ISE75G: 1.000 MPa/ISE76G: 2.50 MPa/ ISE77G: 5.00 MPa/ISE78G: 8.00 MPa Pressure setting Cross recessed round head screw: Nominal size M4 x 6L Cross recessed round head screw: Nominal size M4 x 6L Item Default setting ISE70(G): 0.050 MPa/ISE71
CJ2 series (mm) HA 37 37 S 49 50 ZZ 114 115 Bore size (mm) 10 16 S + Stroke ZZ + 2 x Stroke HA + Stroke Width across flats B3 CM2 series Width across flats MA MM2 MI H3 MK 3 1.5 Stroke ML + Adjustment MT MH + Stroke + Adjustment ZZ + 2 x Stroke + Adjustment (A: 25 mm, B: 50 mm) CM2 Series (mm) B3 10 13 13 17 H3 3.6 5 5 6 MA 12 17 17 19 MI 14 20 20 25 MK 7 9 9 10 MM2 M6 x 1 M8 x 1.25 M8 x
B P_1 or n_1 H_1 P_1=A(AB)/4 n_1=B+(AB)/4 H_1=(AB)/2 Released Workpiece 1 Workpiece 2 Workpiece n Atmosphere B Display value fine adjustment function (F6) Fine adjustment of the indicated value of the pressure sensor can be made within the range of 5% of the read value. (The scattering of the indicated value can be eliminated.) 5% R.D.
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration Certificate: K (Operation Manual + Calibration
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)