Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: B (Bracket B)
Pressure Range: ISE71 (0 to 1.6 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
) 16-2-51 8 Series ISE70/75/75H Pressure Switch Precautions Be sure to read before handling.
) 16-2-51 8 Series ISE70/75/75H Pressure Switch Precautions Be sure to read before handling.
(17) 0 R www.smcworld.com 0x0012 (18) 0 R ISE70-02-L2 0x0013 (19) 0 R ID ISE70-02-L2 0x0014 (20) 0 R Pressure sensor 8 0x0015 (21) 0 R No.
ISE70 0 to 1 MPa ISE71 0 to 1.6 MPa Symbol Description Nil Operation manual Y None K Operation manual + Calibration certificate Piping specification Symbol Description 02 Rc1/4 N02 NPT1/4 F02 G1/4*1 T Calibration certificate Option 2 Symbol Description Nil None *1 ISO 1179-1 compliant Output specification*1 A Bracket A (Interchangeable with ISE70) Symbol Description B Bracket B L2 IO-Link
IODD file 1 ISE70 SMC-ISE70-ymmdd-IODD1.1 2 ISE71 SMC-ISE71-ymmdd-IODD1.1 : "ymmdd" indicates the file preparation date. y is the year, mm is the month and dd is the date. The IODD file can be downloaded from the SMC Web site (https://www.smcworld.com).
ISE70 (Air) ISE75 (Fluid) ISE75H (Fluid) Temperature characteristic (25 C reference: Within operating temperature range) 2%F.S. 3%F.S.
www.stevenengineering.com I 5.16 AIR PREPARATION MODULAR TYPE ACCESSORIES END BLOCK ADAPTOR Port Sizes: M5 ~ 1Rc Allows for easy installation and maintenance H O W T O O R D E R P I P I N G A D A P T O R E10-M5 1000 S E R I E S E20-N01 2000 S E R I E S E20-N02 2000 S E R I E S E20-N03 2000 S E R I E S E30-N02 3000 S E R I E S E30-N03 3000 S E R I E S E30-N04 3000 S E R I E S E40-N03 4000
/ISE75(H) ISE70/ISE75(H) ISE70/ISE75(H) ISE70/ISE75(H) () 1 ON ON OFF Yes No 2 OFF ON 1 OFF 3 4 5 -26No.PS-OMH0002CN-D 6 Yes No 7 7 8 9 10 11 12 13 14 15 -27No.PS-OMH0002CN-D No.
Bracket A Bracket B [F 0] Display units, switch output specifications and diagnostic information selection function ISE70(G): 0.500 MPa/ISE71: 0.800 MPa/ ISE75G: 1.000 MPa/ISE76G: 2.50 MPa/ ISE77G: 5.00 MPa/ISE78G: 8.00 MPa Pressure setting Cross recessed round head screw: Nominal size M4 x 6L Cross recessed round head screw: Nominal size M4 x 6L Item Default setting ISE70(G): 0.050 MPa/ISE71
23 9.5 55.3 1.5 49.3 R 1/4 19 AS331F-02-10ST AS231F-N02-11ST 3/8" 17.9 20.2 18.5 21 32.6 54.4 10 43.7 38.7 31 47 16.2 23 AS331F-02-12ST AS331F-N02-07ST 17 1/4" 13.2 20.9 22 34.4 56.2 12 44.9 38.7 25.6 50 12.9 20.6 AS331F-03-06ST AS331F-N02-09ST NPT 1/4 19 55.3 5/16" 15.2 23 12.8 1.5 49.3 9.5 17 25.2 46.1 6 18.5 38.5 39.7 28.2 54.4 12.9 20.6 AS331F-03-08ST AS331F-N02-11ST 16.2 21 3/8" 17.9
AS221FG-N02-11 33.9 43.2 63 18.5 29.5 41 15.2 17.9 8 3/8" 23 43.8 48.8 21.8 19 42.8 37.8 R 1/4 AS321FG-02-10 AS321FG-N02-07 27.8 39.3 67 21 31.8 43.3 18.5 13.2 10 1/4" 17 60 NPT 1/4 AS321FG-02-12 AS321FG-N02-09 19 21.8 29.5 41 69 22 32.8 44.3 20.9 15.2 12 5/16" 48.8 43.8 42.8 37.8 18.5 63 23 AS321FG-03-06 AS321FG-N02-11 31.8 43.3 55 17 27.8 39.3 12.8 17.9 6 3/8" 21 67 AS321FG-03-08 AS321FG-N03
B P_1 or n_1 H_1 P_1=A(AB)/4 n_1=B+(AB)/4 H_1=(AB)/2 Released Workpiece 1 Workpiece 2 Workpiece n Atmosphere B Display value fine adjustment function (F6) Fine adjustment of the indicated value of the pressure sensor can be made within the range of 5% of the read value. (The scattering of the indicated value can be eliminated.) 5% R.D.
B P_1 or n_1 H_1 P_1=A(AB)/4 n_1=B+(AB)/4 H_1=(AB)/2 Released Workpiece 1 Workpiece 2 Workpiece n Atmosphere B Display value fine adjustment function (F6) Fine adjustment of the indicated value of the pressure sensor can be made within the range of 5% of the read value. (The scattering of the indicated value can be eliminated.) 5% R.D.
AS121FM-U10/32-01 AS121FM-U10/32-03 AS121FM-U10/32-05 AS121FM-U10/32-07 AS221FM-N01-01 AS221FM-N01-03 AS221FM-N01-05 AS221FM-N01-07 AS221FM-N01-09 AS221FM-N02-03 AS221FM-N02-05 AS221FM-N02-07 AS221FM-N02-09 AS221FM-N02-11 1/8" 5/32" 3/16" 1/4" 1/8" 5/32" 3/16" 1/4" 5/16" 5/32" 3/16" 1/4" 5/16" 3/8" 8.4 9.3 11.4 12 12.7 22.1 12.3 17.3 7 9.6 30.1 28.8 25.1 8 33.8 10-32 UNF 16.5 13.5 26.1 23.1
M1 M2 Weight (g) ASV310F-N01-07 ASV310F-N01-09 ASV310F-N02-07 ASV310F-N02-09 ASV410F-N01-09 ASV410F-N01-11 ASV410F-N02-09 ASV410F-N02-11 ASV410F-N03-09 ASV410F-N03-11 ASV510F-N02-11 ASV510F-N02-13 ASV510F-N03-11 ASV510F-N03-13 ASV510F-N04-11 ASV510F-N04-13 17.2 19.3 17.2 19.3 19.3 23.3 19.3 23.3 19.3 23.3 23.3 26.5 23.3 26.5 23.3 26.5 73 73.8 73 73.8 83.1 85.2 83.1 85.2 83.1 85.2 90.2 91.9