VVQ1000-1A-3Electrical entry F1: For F kit P1: P, G, T, S kit for 1 to 12 stations/Double wiring P2: G, S kit for 13 to 16 stations/Double wiring P3: G, S kit for 1 to 16 stations/Single wiring L0: L0 kit L1: L1 kit L2: L2 kit Lead wire assembly for extensions is attached. Note) Note) Note) Note) : Stations (1 to 16)
n Dimensions 8 263 276 L1 L2 7 238 251 8 263 276 L1 L2 6 213 226 7 238 251 5 188 201 6 213 226 4 163 176 5 188 201 3 138 151 4 163 176 1 2 113 126 3 138 151 1 2 113 126 88 101 88 101 L n L n 9 288 301 15 463 476 14 413 426 13 388 401 12 363 376 11 338 351 10 313 326 9 288 301 16 463 476 15 463 476 14 413 426 13 388 401 12 363 376 11 338 351 10 313 326 16 463 476 L1 L2 L1 L2 2-5-37 Base Mounted
A A A A A A B B B B B B B B 7 SMC SMC SMC SMC SMC SMC SMC 6 5 L1 L2 4 3 2 44 P = 25 50.5 P = 25 1 X Stations 12 38 26.5 Electrical entry on D side (LD) 37.5 10.2 12 91 D side 43.5 50.5 163 59 96.5 Dimensions Formula L1 = 25n + 63, L2 = 25n + 76 n: Station (Maximum 16 stations) L n 8 263 276 L1 L2 7 238 251 6 213 226 5 188 201 4 163 176 3 138 151 1 2 113 126 16 463 476 15 438 451 14 413 426
V td (13.1) L1 60 2 L1 : Proximity dog length [mm] V : Home position return speed [mm/min] Td : Deceleration time [s] L2 2 S (13.2) L2 : Proximity dog length [mm] S : Travel distance per servo motor revolution [mm] 13 54 13.
= 41n + 96 n: Stations (Maximum 12 stations) Formula: L1 = 41n + 76, L2 = 41n + 96 n: Stations (Maximum 12 stations) L n Dimensions 2 158 178 9 445 465 2 158 178 9 445 465 3 199 219 10 486 506 3 199 219 10 486 506 4 240 260 11 527 547 4 240 260 11 527 547 5 281 301 12 568 588 5 281 301 12 568 588 6 322 342 6 322 342 7 363 383 7 363 383 8 404 424 L1 L2 8 404 424 L1 L2 2-6-37 Base Mounted
Name of terminal block (LED) Note VQZ POWER RUN SD RD ERR RUN ERR TRD 10 1 VQD 24V 0V + + FG L1 L2 SG L1 L2 SG 24V 0V Description ON when power supply is ON LED Description LED POWER Lights when transmission is normal and PLC is in operation mode RUN Lights when power is ON and slave stations are operating normally RUN T/R ERR Blinks during data transmission/reception ON when transmission
B 2 A 4 3 B A B 2 A 4 2 B A 34.5 46 68.5 P = 41 A 4 B 2 1 B A 58.5 X 12 Stations 2-Rc 1/8 (External pilot port) 15.5 22 51 69 117 42 16 107.8 179 D side With connector on D side (FD) Formula: L1 = 41n + 76, L2 = 41n + 96 n: Stations (Maximum 12 stations) Dimensions L n 12 568 588 L1 L2 11 527 547 10 486 506 9 445 465 8 404 424 7 363 383 6 322 342 5 281 301 4 240 260 3 199 219 2 158 178 1
Pressure Range: ISE76G (0 to 5 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE75[H]), Operation Manual/Calibration Certificate: K (Operation Manual + Calibration Certificate)
Pressure Range: ISE76G (0 to 5 MPa), Piping: N02 (NPT 1/4), Orifice: None
Pressure Range: ISE76G (0 to 5 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
Pressure Range: ISE76G (0 to 5 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: B (Bracket B), Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE76G (0 to 5 MPa), Piping: N02 (NPT 1/4), Orifice: T (Orifice shipped with the Product)
Pressure Range: ISE76G (0 to 5 MPa), Piping: N02 (NPT 1/4), Orifice: T (Orifice shipped with the Product), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
Pressure Range: ISE76G (0 to 5 MPa), Piping: N02 (NPT 1/4), Orifice: T (Orifice shipped with the Product), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: None, Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE76G (0 to 5 MPa), Piping: N02 (NPT 1/4), Orifice: T (Orifice shipped with the Product), Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)