This is a legacy product. Please contact us for the latest version.sales@ocaire.com, Operation Manual, REGULATOR, ELECTRO-PNEUMATIC, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, EB, IT2000 3/8 INCNPT VERSION, 1.52240 lb, ModelITV101 ITV103 ITV105 ITV201 ITV203 ITV205 ITV205------------
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, Operation Manual, REGULATOR, ELECTRO-PNEUMATIC, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, EB, IT2000 3/8 INCNPT VERSION, .77161 lb, ModelITV101 ITV103 ITV105 ITV201 ITV203 ITV205 ITV205------------
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, Operation Manual, REGULATOR, ELECTRO-PNEUMATIC, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, EB, IT2000 3/8 INCNPT VERSION, .77161 lb, ModelITV101 ITV103 ITV105 ITV201 ITV203 ITV205 ITV205------------
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, Operation Manual, REGULATOR, ELECTRO-PNEUMATIC, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, EB, IT2000 3/8 INCNPT VERSION, .77161 lb, ModelITV101 ITV103 ITV105 ITV201 ITV203 ITV205 ITV205------------
-212S-X26 SMC REGULATOR SMC REGULATOR VBA UNLOCK LOCK RESET SET VE VY G 1 2 3 Stations AL Manifold base (3 stations) IITV20-02-3 (1) 1set (3 station manifold base part no.) 1set (Electro-pneumatic regulator part no.) (2) IITV20-02-3 ITV2030-312S-X26 P398020-13 ITV2050-212S-X26 1set (Blanking plate assembly part no.) 1set (Electro-pneumatic regulator part no.) (2) The is the symbol for
-212S-X26 SMC REGULATOR SMC REGULATOR VBA UNLOCK LOCK RESET SET VE VY G 1 2 3 Stations AL Manifold base (3 stations) IITV20-02-3 (1) 1set (3 station manifold base part no.) 1set (Electro-pneumatic regulator part no.) (2) IITV20-02-3 ITV2030-312S-X26 P398020-13 ITV2050-212S-X26 1set (Blanking plate assembly part no.) 1set (Electro-pneumatic regulator part no.) (2) The is the symbol for
Part Number Description: MOUNTING BRACKET ITV2050 Product Line: I Product Line Description: INSTRUMENTATION Family Code: 823 Family Description: IT2000/ITV2000 E/P REGULATOR Class Code: E1 Part Code: 2 Reference Code: J Click here to report information errorImage shown may not match exact part number, MOUNTING BRACKET ITV2050, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR
Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com E SMC REGULATOR 2 OUT P G Connection thread type MPa IR N F PT NPT PF SUP 2 VEX G Manifold base (3 stations) 1 2 3 AMR IITV20-02-3 ITV2030-311S-X26 P398020-13 ITV2050-212S-X26 1 set (3 station manifold base part no.) 1 set (Electro-pneumatic regulator part no.)
4 0 N 2 B S X80 2 0 3 0 ITV 33 DeviceNet compatible Model 2000 type 3000 type 2 3 Thread type Pressure range Rc(PT) NPT NPTF G(PF) Nil N T F Cable connector type 0.005 to 0.1MPa 0.005 to 0.5MPa 0.005 to 0.9MPa 1 3 5 Without Straight type 3m Nil S Option (bracket) Port size Without bracket Flat bracket L-bracket Nil B C 1/4 3/8 2 3 Specifications ITV2050 ITV3050 ITV2030 ITV3030 ITV2010 ITV3010
Input Signal: 3 (Voltage Type 0 to 10 VDC), Monitor Output: 1 (Analog Output 1 to 5 VDC), Thread Type: N (NPT), Bracket: B (Flat Bracket), Cable Connector Type: S (Straight Type 3m)
Model: 20 (1500 L/min), Pressure Range: 3 (0.005~0.5MPa), Power Voltage: 1 (12~15VDC), Input Signal: 3 (Voltage Style 0~10VDC), Monitor Output: 1 (Analog Output 1~5VDC), Thread: N (NPT), Port Size: 3 [3/8 (2000,3000)], Accessory: B (Flat Bracket), Cable Connector: S (Straight Style 3m)
Model: 20 (1500 L/min), Pressure Range: 3 (0.005~0.5MPa), Power Voltage: 0 (24VDC), Input Signal: 3 (Voltage Style 0~10VDC), Monitor Output: 1 (Analog Output 1~5VDC), Thread: N (NPT), Port Size: 3 [3/8 (2000,3000)], Accessory: B (Flat Bracket), Cable Connector: S (Straight Style 3m)
Input Signal: 3 (Voltage Type 0 to 10 VDC), Monitor Output: 1 (Analog Output 1 to 5 VDC), Pipe Thread: N (NPT), Port Size: 3 (3/8), Bracket: B (Flat Bracket), Cable Connector: S (Straight Type 3 m)
Input Signal: Voltage Type 0 to 10 VDC, Monitor Output: Analog Output 1 to 5 VDC, Pipe Thread: NPT, Port Size: 3/8, Bracket: Flat Bracket, Cable Connector: Straight Type 3 m, Pressure Display Unit: -
Regulator, Pressure Boosting Valve: Regulator, Regulator Type: Electropneumatic, Shape: Standard, Operating Environment: Standard, Compatible Fluid: Air / Nitrogen / Gas, Exhaust Mechanism (Air Bleed): [Included] Yes, Reverse Flow Function (Relief): No, Supply Side Connection Type: [NPT] NPT, Supply Side, Connection Diameter: 3/8, Flow Direction: [Right] From Left to Right, Control Side Connection
Model: 1500 L/min, Pressure Range: 0.005~0.5MPa, Power Voltage: 12~15VDC, Input Signal: Voltage Style 0~10VDC, Monitor Output: Analog Output 1~5VDC, Thread: NPT, Port Size: 3 [3/8 (2000,3000)], Accessory: Flat Bracket, Cable Connector: Straight Style 3m, Pressure Display Unit: -, Options: -
Model: 1500 L/min, Pressure Range: 0.005~0.5MPa, Power Voltage: 24VDC, Input Signal: Voltage Style 0~10VDC, Monitor Output: Analog Output 1~5VDC, Thread: NPT, Port Size: 3 [3/8 (2000,3000)], Accessory: Flat Bracket, Cable Connector: Straight Style 3m, Pressure Display Unit: -, Options: -
Series ITVX2000 high pressure electro-pneumatic regulator provides stepless control of air pressure to an electrical signal. They have an easy to read digital pressure display and a power consumption of 3 W or less. The new series has a 5.0 MPa maximum supply pressure. Stepless control of air pressure proportional to an electrical signalMaximum supply pressure: 5.0 MPaSet pressure range
Series ITV electro-pneumatic and electronic vacuum regulators control air/vacuum pressure steplessly in proportion to an electric signal. They are light weight in design with a bright and easy to read LED display. The monitor output is available either as analog output or switch output. The ITV series is IP65 equivalent.Controls air pressure in proportion to an electric signal., Available