Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LER10J, I/O cable length / communication plug(m): Without I/O cable, Controller/driver mounting method: Screw mounting type
Table Accuracy: Basic, Size: 10, Max. Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3)
Table Accuracy: Basic, Size: 10, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Standard Cable, Actuator Cable Length: 3, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Option: -, Communication Plug Connector or I/O Cable Length for
Table Accuracy: Basic, Size: 10, Max. Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: 3 (External Stopper: 90°), Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3)
Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: 2 (External Stopper: 180°), Motor Cable Entry: L (Entry on the Left Side), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3)
Table Accuracy: Basic Type, Size: 10, Max. Rotation Torque: J (Basic, LER10: 0.22; LER30: 0.8; LER50: 6.6), Motor Cable Entry: Basic Type, Entry on Right Side, Actuator Cable Type: S (Standard Cable), Actuator Cable Length: 3 (3m)
Table Accuracy: Basic, Size: 10, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: External Stopper: 90°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Standard Cable, Actuator Cable Length: 3, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Option: -, Communication Plug Connector or I/O Cable Length for JXC: -
Table Accuracy: Basic Type, Size: 10, Max. Rotation Torque: Basic, LER10: 0.22; LER30: 0.8; LER50: 6.6, Motor Cable Entry: Basic Type, Entry on Right Side, Actuator Cable Type: Standard Cable, Actuator Cable Length: 3m, Controller Type - JXC: -, Controller Mounting: -, Communication Plug Connector for DeviceNetâ„¢: -
Oscillation Angle A: [180°] External Stopper, Torque (Range)(N⋅m): Less than 1, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Rigidity Accuracy: Standard, Environment, Applications: High-Speed, Valves: Not Provided, Torque(N⋅m): 0.22, Size: 10, Motor cable entry direction: Entry on the left side, Actuator cable type: Standard cable, Actuator cable length(m): 3
Connector location Connector location P.1.10-124 P.1.10-128 P.1.10-132 Top (vertical) Side (honzontal) Top (vertical) Side (honzontal) Without cable With cable (1.5m) With cable (3m) With cable (5m) Without cable Without cable F F S0 S1 S2 S3 P P S0 S1 S2 S3 S0 S1 S2 S3 U0 U1 U2 U3 U0 U1 U2 U3 U0 U1 U2 U3 0 1 2 3 (2) (2) (2) G 2 to 16 stations With cable (1.5m) With cable (3m) With cable
Scale: 25% For external pilot specification (Pitch) P = 24 24.3 22.2 11 18.3 18.8 39.3 18.8 3/5 R 3/5 R A 4 A 4 A 4 A 4 18 A 4 A 4 3/5 R 3/5 R A 4 A 4 A 4 A 4 39.3 40.1 A 4 A 4 63.3 79.8 1 P 1 P B 2 B 2 B 2 B 2 B 2 B 2 2-Plug [1 (P), 3/5 (R) port] 1 P 1 P B 2 B 2 B 2 B 2 B 2 B 2 2-One-touch fitting [1 (P), 3/5 (R) port] Applicable tube O.D.: 12 2n1-One-touch fitting [4 (A), 2 (B) port] Applicable
Kit/Electrical entry/Cable length F P kit (D-sub connector) kit (Flat ribbon cable connector) Top entry Side entry Top entry 26P Note 2) Side entry 26P Note 2) 25P Note) 25P Note) Connector entry direction Top entry Side entry Connector entry direction Top entry Side entry P. 2-4-38 P. 2-4-42 U0 U1 U2 U3 U0 U1 U2 U3 S0 S1 S2 S3 S0 S1 S2 S3 Without cable Without cable (2) (2) With cable (1.5
(With 2 input blocks) With external pilot specification 46.5 (Pitch) 15.8 9.5 16.5 20.5 17.5 P = 16 M3 M12 11.9 9.2 17.7 25.2 30.6 3 3 4 A 4 A 4 A 4 A 4 A 3 3 3/5 E PWR 49.9 42.7 4 A 4 A 4 A 4 A 4 A E 3/5 3/5 E PWR 2 2 E 3/5 63.5 2 2 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 1 1 1 1 1 P P 1 BUS 0 P 1 1 P BUS 0 0 0 X PE PE x One-touch fitting [4(A), 2(B) port] Applicable tubing O.D.: 4, N3 6
(With 2 input blocks) With External Pilot Specifications 46.5 (Pitch) 2-M12 M3 16.5 18.3 13.5 P = 10.5 14.1 8.4 SV 8.6 10 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 17.7 24.6 23 59.5 SZ 3 3 PWR 3 3 42.7 5 3 E 3 5 E 5 3 E 3 5 E T T 43 PWR 56.5 2 2 2 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 1 P 1 P 1 P 1 P One-touch fitting [1(P), 3/5(E) port] Applicable tubing O.D.: 8 5/16" 1 1 1 1 BUS 4632
EX300-T001General purpose MELSECNET/MINI-S3 Data Link System Master unit: AJ71PT32-S3 AJ71T32-S3 A1SJ71PT32-S3 No. of output point, 16 points No. of sta. occupied, 2 stations Each T unit has 32 control points.
Series MELSEC-A AJ71PT32-S3, AJ71T32-S3 A1SJ71PT32-S3 Max. 64 stations, connected to remote I/O stations (Max. 512 points). 16 outputs, 2 stations occupied.
B-1 A-1 B-2 A-2 B-3 A-3 Circuit Cable color Brown Red Orange Yellow Green Blue A A B B COM-A/COM COM-B/ 2 1 6 5 3 4 Cable color Connector D terminal no.
D side mounting (2) Manifold (3) 1 Plug-in unit Model (2) (2) 0 A Without SI unit With general type SI unit (Series EX300) Mitsubishi Electric Corp.: MELSECNET/MINI-S3 Data Link System Stations (2) Note 1) When two or more symbols are specified, indicate them alphabetically.
exhaust with silencer box: U side exhaust IP65 enclosure Model 5 VQ5000 O A Without SI unit With general type SI unit (Series EX300) (2) (2) Manifold Mitsubishi Electric Corp.: MELSECNET/MINI-S3 Data Link System (2) B 1 Plug-in unit (2) Mitsubishi Electric Corp.: MELSECNET/MINI-S3 Data Link System (2 power supply systems) BB (3) Stations (2) C D F1 J1 J2 K Q R1 R2 U V G H OMRON Corp.: SYSBUS
How to Order 25A-LEFS 32 H R S3 B 200 S 2 A2 Series compatible with secondary batteries q w e r t u !1 y i o !