Size: 8, Motor Mounting Position: R (Basic Type), Motor Type: Step Motor, (Servo/24 VDC), Lead: J (LES8: 8mm; LES16: 10mm; LES25: 16mm), Stroke: 75mm, Motor Option: B (w/Lock), Body Option: Basic Type, Mounting: w/o Side Holder, Actuator Cable Type: R (Robotic Cable, Flexible Cable), Actuator Cable Length: C (20m), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type),
Size: 8, Motor Mounting Position: Basic Type, Motor Type: Step Motor, (Servo/24 VDC), Lead: LES8: 8mm; LES16: 10mm; LES25: 16mm, Stroke: 75mm, Motor Option: w/Lock, Body Option: Basic Type, Mounting: w/o Side Holder, Actuator Cable Type: Standard Cable, Actuator Cable Length: 1.5m, Controller Type: LECPMJ, CC-Link, Direct Input Type, I/O Cable Length: w/o Cable, Communication Plug Connector
Size: 8, Motor Mounting Position: Basic Type, Motor Type: Step Motor, (Servo/24 VDC), Lead: LES8: 8mm; LES16: 10mm; LES25: 16mm, Stroke: 75mm, Motor Option: w/Lock, Body Option: Basic Type, Mounting: w/o Side Holder, Actuator Cable Type: Robotic Cable, Flexible Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC:
Size: 8, Motor Mounting Position: Basic Type, Motor Type: Step Motor, (Servo/24 VDC), Lead: LES8: 8mm; LES16: 10mm; LES25: 16mm, Stroke: 75mm, Motor Option: w/Lock, Body Option: Basic Type, Mounting: w/o Side Holder, Actuator Cable Type: Robotic Cable, Flexible Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC:
Size: 8, Motor Mounting Position: Basic Type, Motor Type: Step Motor, (Servo/24 VDC), Lead: LES8: 8mm; LES16: 10mm; LES25: 16mm, Stroke: 75mm, Motor Option: w/Lock, Body Option: Basic Type, Mounting: w/o Side Holder, Actuator Cable Type: Standard Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC: w/o Cable, Controller
Size: 8, Motor Mounting Position: Basic Type, Motor Type: Step Motor, (Servo/24 VDC), Lead: LES8: 8mm; LES16: 10mm; LES25: 16mm, Stroke: 75mm, Motor Option: w/Lock, Body Option: Basic Type, Mounting: w/o Side Holder, Actuator Cable Type: Standard Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector
Size: 8, Motor Mounting Position: Basic Type, Motor Type: Step Motor, (Servo/24 VDC), Lead: LES8: 8mm; LES16: 10mm; LES25: 16mm, Stroke: 75mm, Motor Option: w/Lock, Body Option: Basic Type, Mounting: w/o Side Holder, Actuator Cable Type: Robotic Cable, Flexible Cable, Actuator Cable Length: 20m, Controller Type - LEC, JXC: JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC:
For AFF2C to 22C, 37B, 75B, AM150C to 550C, 650, and 850 The pressure drop reaches 0.1 MPa or two years have elapsed after operation start, whichever comes earlier. [The pressure drop can be checked using the equipment with the element service indicator (-T) or differential pressure gauge (made to order specifications).] b.
For AFF2C to 22C, 37B, 75B, AM150C to 550C, 650, and 850 The pressure drop reaches 0.1 MPa or two years have elapsed after operation start, whichever comes earlier. [The pressure drop can be checked using the equipment with the element service indicator (-T) or differential pressure gauge (made to order specifications).] b.
For AFF2C to 22C, 37B, 75B, AM150C to 550C, 650, and 850 The pressure drop reaches 0.1 MPa or two years have elapsed after operation start, whichever comes earlier. [The pressure drop can be checked using the equipment with the element service indicator (-T) or differential pressure gauge (made to order specifications).] b.
Body Size: 75B, Thread: N (NPT), Port Size: 20 (2), Accessory: B (Bracket)
Body Size: 75B, Thread: N (NPT), Port Size: 14 (1 1/2)
Body Size: 75B, Thread: N (NPT), Port Size: 20 (2), Accessory: B (Bracket), Auto Drain: Drain Cock w/o Auto Drain, Drain Guide: None, IN-OUT Direction: None, Element Service Indicator: T (w/Element Service Indicator)
Body Size: 75B, Thread: N (NPT), Port Size: 20 (2), Accessory: B (Bracket), Auto Drain: Drain Cock w/o Auto Drain, Drain Guide: None, IN-OUT Direction: R (IN-OUT Reversal Direction), Element Service Indicator: T (w/Element Service Indicator)
Body Size: 75B, Thread: Rc, Port Size: 20 (2), Accessory: None, Auto Drain: Drain Cock w/o Auto Drain, Drain Guide: None, IN-OUT Direction: None, Element Service Indicator: T (w/Element Service Indicator)
This is a legacy product, and replaced byMXS12-75B-M9PWL
Refer to the separate catalog ES11-75B regarding DIN rail weight. L type (for plug-in) Electrical entry Rated coil voltage 24VDC 10% of rated voltage Allowable voltage fluctuation 0.65W Power consumption Diode Surge voltage suppressor LED Indicator light Response Time Note) Based on JISB8375-1981 dynamic performance test (with coil temperature of 20C and at rated voltage).
Completion of setting CAT.ES100-75B Series ZSE10(F)/ISE10 Improved visibility from multiple directions The vacuum suction and burst pressure can be checked at a glance by indicator lights.
Inlet pressure (MPa) 14-20-9 2 Series AFF How to Order AFF2B to AFF75B AFF 8B 03 J B Option Body size J Drain guide B female thread R IN-OUT reversal direction T Element service indicator 1 4 2B 4B 8B 11B 22B 37B 75B Standard 1 8 Standard 1 4 Standard 3 8 Standard 1 2 Standard 3 4 Accessory (Option) Symbol Description Bracket Nil B 1 Standard 11 2 Standard N.C. auto-drain C N.O. auto-drain
For early stage second-generation models AFF2B to 75B and AM□150 to 850 as well as later stage second-generation models AFF2C to 22C and AM□150C to 550C, a replacement element service indicator can be ordered with the same part number (INA-63-280).