Insulation resistance Between external terminal batch and case: 2M (at 500VDC) 2hrs. each in X, Y, Z directions at smaller of 10 to 500Hz with amplitude 1.5mm, or acceleration 10G Vibration resistance 100G in X, Y, Z directions, 3 times each Impact resistance Note 1) Not available on analog output type. Refer to CAT.E824-A "Pressure Switch" for details on switches.
(in rated pressure range) Linearity: 1% F.S. or less Output impedance: Approx. 1k Analog output (Note 2) Auto shift input (Note 3) Enclosure Ambient temperature range Ambient humidity range Withstand voltage Environmental resistance Insulation resistance 10 to 500Hz at the smaller of amplitude 1.5mm or acceleration 98m/s (10G) in X, Y, Z directions for 2hrs. each (deenergized) 980m/s (100G
Maximum load mass: 1000g (horizontal), 100g (vertical); Maximum pushing force: 5.5N; Strokes: 10, 20, 30 mm; Weight: 130, 190, or 250g (stroke dependent); Positioning repeatability: ±5 µ m (“F” resolution option); Parts measurement repeatability: ±10 µ m (“F” resolution option)
Maximum load mass: 500g (horizontal), 100g (vertical) ; Maximum pushing force: 5.5N ; Strokes: 10, 20, 30 mm ; Weight: 130, 190, or 250g (stroke dependent) ; Positioning repeatability: ±5 µm (“F” resolution option) ; Parts measurement repeatability: ±10 µm (“F” resolution option)
Maximum load mass: 500g (horizontal), 100g (vertical) ; Maximum pushing force: 5.5N ; Strokes: 10, 20, 30 mm ; Weight: 130, 190, or 250g (stroke dependent) ; Positioning repeatability: ±5 µm (“F” resolution option) ; Parts measurement repeatability: ±10 µm (“F” resolution option)
Leaka0e cuffenl 0 0 24VDC@ 1oFA or less 24VDC@1mA or lesr ope16ling time 'l.2mS 'L2mS 1 m S lndicator lamp None ON: Red light emitting diode Lead wire entry Grommet Oil resistant vinyl sheathed lead wire 02.7, 0.15mm, (3-core); o3.2, 0.18mm, (2-core) Heat resistant vinyl sheathed lead wire u.zmm', z cofe u.5m 3 core (Red, White, Black) 0.5m 2 core (Red, Black) 0.5m lmpacl resishnce 30G 100G
85% RH (with no condensation) Ambient humidity range Withstand voltage Environmental resistance 1000VAC for 1min. between lead wires and body 50MW or more (at 500VDC) between lead wires and body Insulation resistance 10 to 500Hz at the smaller of amplitude 1.5mm or acceleration 98m/sX (10G) in X, Y, Z directions for 2hrs. each (deenergized) Vibration resistance Impact resistance 980m/sX (100G
splash-proof (IP65 equivalent) Three compact sizes available Grommet DIN connector Conduit Conduit terminal VCA20 Class 2 VCA30 Class 3 VCA40 Class 4 23 Compact Direct Operated 2/3 Port Solenoid Valve SeriesVDW For Water and Air Compact (compared to series VX) Single valve volume: Reduced 75% (VDW20) Manifold length: Reduced 18% (VDW30, 7 stations) Light weight (compared to series VX) 100g
Leaka0e cuffenl 0 0 24VDC@ 1oFA or less 24VDC@1mA or lesr ope16ling time 'l.2mS 'L2mS 1 m S lndicator lamp None ON: Red light emitting diode Lead wire entry Grommet Oil resistant vinyl sheathed lead wire 02.7, 0.15mm, (3-core); o3.2, 0.18mm, (2-core) Heat resistant vinyl sheathed lead wire u.zmm', z cofe u.5m 3 core (Red, White, Black) 0.5m 2 core (Red, Black) 0.5m lmpacl resishnce 30G 100G
Magnet: D (Built-in), Mounting: L (Foot), Bore Size: 20mm, Stroke: 100mm, Rod End Thread: G (Long Male Rod End)
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Auto Switches: Without auto switch, Lead Wire Length
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Without magnet, Auto Switches: Without auto switch, Lead Wire Length(m
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Without magnet, Auto Switches: Without auto switch, Lead Wire Length(m
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Without built-in magnet, Support bracket: Without auto switch mounting
Magnet: None, Mounting: D (Clevis), Bore Size: 50mm, Stroke: 100mm, Rod End Thread: G (Long Male Rod End)
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 40mm, Stroke: 100mm, Rod End Thread: G (Long Male Rod End)
Magnet: None, Mounting: B (Basic), Bore Size: 63mm, Stroke: 100mm, Rod End Thread: G (Long Male Rod End)
Magnet: None, Series: 85 (Standard), Head Cover Type: N (Basic Integrated Clevis), Bore Size: 20mm, Stroke: 100mm, Cushion: Rubber Cushion, Rod Boot: None, Mounting Bracket: G (Flange)
Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 32mm, Stroke: 100mm, Rod End Thread: G (Long Male Rod End)
Magnet: None, Mounting: E (Integral Clevis), Bore Size: 32mm, Stroke: 100mm, Rod End Thread: G (Long Male Rod End)