SMC Corporation of America
Elite Part Number Search
Search Results "LEY25C-30C-S1C918"

Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 100mm, Motor Option: B (w/Lock), Rod End Thread: Female, Mounting: D (Double Clevis), Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5m), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), I/O Cable Length

Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 100mm, Motor Option: B (w/Lock), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5m), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), I/O Cable

Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 100mm, Motor Option: None, Rod End Thread: Female, Mounting: D (Double Clevis), Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5m), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), I/O Cable Length for LEC

Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 100mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5m), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), I/O Cable Length

Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 50mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC: Without

Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 300mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC: Without

Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 30mm, Motor Option: w/Motor Cover, Rod End Thread: Female, Mounting: Rod Flange, Actuator Cable: Standard Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC: Without Cable

Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 100mm, Motor Option: w/Lock, Rod End Thread: Female, Mounting: Double Clevis, Actuator Cable: Standard Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC: Without Cable, Controller

Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 100mm, Motor Option: w/Lock, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC: Without

Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 100mm, Motor Option: None, Rod End Thread: Female, Mounting: Double Clevis, Actuator Cable: Standard Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC: Without Cable, Controller

Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 100mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC: Without

Conditions/Inlet air pressure 0.7 MPa Inlet air temperature 30C Precautions Pink Be sure to read before handling. Refer to pages 14-21-3 to 14-21-4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to pages 14-14-6 to 14-148 for Precautions on every series.

1.00 4.18 x 103 1.00 1 x 103 30C 1.01 3.91 x 103 1.01 0.94 x 103 35C 0.99 4.18 x 103 0.99 1 x 103 35C 1.01 3.91 x 103 1.01 0.94 x 103 40C 0.99 4.18 x 103 0.99 1 x 103 40C 1.01 3.92 x 103 1.01 0.94 x 103 Note) The above shown are reference values.

AMG Color of indicator Dew point temperature (Atmospheric pressure) 30C or less 18C 10C Dark blue Light blue Light pink Conditions/Inlet air pressure 0.7 MPa Inlet air temperature 30C Please use the adsorbent set (refer to page 134 for Accessory/ Replacement Parts) when replacing the adsorbent. AFF Piping Caution AM AMD 1.

(Note 4) Perfect dry air (dew point equals to -30C) No grease on main valve.

(Note 4) Perfect dry air (dew point equals to -30C) No grease on main valve.

Given an ambient temperature of 30C and a relative humidity of 60%. Trace the arrow mark, from point A of ambient temperature 30C to obtain the intersection B on the curved line for the relative humidity of 60%. Trace the arrow mark, from the intersection B to obtain the intersection D on the curved line for the 0.7 MPa pressure characterisitics.

Cool from 30C (303 K) to 20C (293 K). Circulating fluid : Tap water Density : 1 x 103 kg/m3 Specific heat C : 4.2 x 103 J/(kgK) Refer to the information shown below for the typical physical property values by circulating fluid. Water bath Q = T x V x x C h x 60 x 1000 10 x 2 x 1 x 103 x 4.2 x 103 20C V = 15 x 60 x 1000 After 15 min, = 93.3 W cool 30C down to 20C.

Water Physical property value Temperature Density [kg/L] Specific heat C [J/(kgK)] Conventional units Weight volume ratio [kgf/L] Specific heat C [cal/(kgfC)] 5C 1.00 4.2 x 103 1.00 1 x 103 10C 1.00 4.19 x 103 1.00 1 x 103 15C 1.00 4.19 x 103 1.00 1 x 103 20C 1.00 4.18 x 103 1.00 1 x 103 25C 1.00 4.18 x 103 1.00 1 x 103 30C 1.00 4.18 x 103 1.00 1 x 103 35C 0.99 4.18 x 103 0.99 1 x 103 40C

1.00 4.18 x 103 1.00 1 x 103 30C 1.01 3.91 x 103 1.01 0.94 x 103 35C 0.99 4.18 x 103 0.99 1 x 103 35C 1.01 3.91 x 103 1.01 0.94 x 103 40C 0.99 4.18 x 103 0.99 1 x 103 40C 1.01 3.92 x 103 1.01 0.94 x 103 * Shown above are reference values.