Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LEY32C-30, I/O cable length / communication plug(m): Without I/O cable, Controller/driver mounting method: Screw mounting type

Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LEY32C-100, I/O cable length / communication plug(m): Without I/O cable, Controller/driver mounting method: Screw mounting type

Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LEY32C-100, I/O cable length / communication plug(m): Without I/O cable, Controller/driver mounting method: DIN rail mounting type

Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 30mm, Motor Option: None, Rod End Thread: M (Male), Mounting: D (Double Clevis), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3m)

Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 200mm, Motor Option: B (w/Lock), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3m)

Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 150mm, Motor Option: B (w/Lock), Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3m)

Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 150mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3m)

Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 30mm, Motor Option: None, Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3m)

Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 200mm, Motor Option: w/Lock, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug

Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 150mm, Motor Option: w/Lock, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug

Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 30mm, Motor Option: None, Rod End Thread: Male, Mounting: Double Clevis, Actuator Cable: Standard Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector or I/

Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 150mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug

Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 30mm, Motor Option: None, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector

Size: 0425 (ODØ4 IDØ2.5), Color: W (White), Roll Length: None, Reel Length: 500m, Made to Order: X3 (Reel Length)

NG NO OK OK YES Model selected Selection Example 1 Selection Example 2 Actuating orientation: Horizontal transfer of work (without external guide) Max. speed: u=200mm/s Supply pressure: P=0.5MPa Load weight: M=0.2kgR2N Cylinder stroke: 300mm Actuating orientation: Vertical transfer of work (Rear flange) Max. speed: u=300mm/s Supply pressure: P=0.5MPa Load weight: M=10kg Cylinder stroke: 500m

Impact Endurance 500m/s (About 50G) XYZ direction 10 times Enclosure IEC standard IP67 (JEM standard IP67G Drip proof, Oil proof) Note 1) At load current 100mA and cord length 2m Note 2) Between case and whole charging part Dimensions E2E-X1C1 (RSH20/32) 25 17.5 8 15 * Indicator light * Polyvinyl chloride round cord (Oil and vibration proof) 0.14mm2 X 3 wire O.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Operating ambient humidity 35 to 95% RH Note 1) Residual voltage 2V or less 3V or less Note 2) Withstand voltage 500VAC 1000VAC Vibration Endurance 10 to 55 Hz, Duplex amplitude 1.5mm X,Y,Z direction each 2h Impact Endurance 500m/s2 (approx. 50G), X,

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Operating ambient humidity 35 to 95% RH Note 1) Residual voltage 2V or less 3V or less Note 2) Withstand voltage 500VAC 1000VAC Vibration Endurance 10 to 55 Hz, Duplex amplitude 1.5mm X,Y,Z direction each 2h Impact Endurance 500m/s2 (approx. 50G), X,

Read this operation manual with taking a look at the unit to facilitate your understanding. 1.2 Operation by external communication It complies with communication standard RS-232C or RS-485 and can have a cable with length up to 15m or 500m.

E2E-X2D1-N () DC1224V(DC1030V),(P-P) () 0.8mA 1.5kHZ () 3100mA (LED) (LED) -2570() 3595%RH 1 2 3V AC1000V 1055HZ1.5mmXYZ 2h 2(50G) XYZ 10 500m/S IEC IP67(JEM IP67G ) 1)100mA 2m 2) 8-2. -19-19-19-90 -19-19-1920 - 1. 2. 3. 1. 2. 3. 4. 5. 6. 7. 1. 2. 1. 2. 1. 2. 1. 2. 3. 1. 2. 3. () 4. 5. 1. 2. 1. 2. 1. ON (ON) 1. , 2. ON 3. 60 4.