How to Order EX500 G DN 1 Applicable GW unit Communication protocol DeviceNet PROFIBUS-DP Remote I/O (RIO) DN PR AB DeviceNet PROFIBUS-DP Nil Remote I/O (RIO) -X1 Dimensions 148 E x 500-GAB1-X1 VOLTAGE 24VDC/200mA INPUT/OUTPUT 64/64 IP CODE IP65 SERIAL NO.

DMade to Order Specifications: 201 Oil Resistant Specifications 2 Heat Resistant Specifications -X5 -X4 D X5 Bore size Stroke symbol Solid state switch MHL2 D X4 Bore size Stroke symbol MHL2 The packing class has been revised to adopt oil resistant materials for using it in an environment with splashing of cut liquid splashing etc.

M4 Y3 7 to 8 Y = 10 15 7 to 14 M4 X3 M5 Y3.5 8.5 to 9 L2 = L1 = 15 20 M5 X3.5 8.5 to 18 M6 Y4 10 20 30 X = M6 X4 10 to 20 M8 Y5 13 30 40 M8 X5 13 to 22 M10 Y6 15 Symbol: A5 Symbol: A6 The long shaft can be further shortened by machining it into a stepped round shaft. (If shortening the shaft is not required, indicate "" for dimension X.)

24 V (control and input) X4 0 V (control and input) X7 0 V (control and input) X6 0 V (control and input) X5 0 V (control and input) X4 24 V (control and input) 24 V (control and input) 0 V (control and input) Signal name Signal name Input 15 Input 14 Input 13 Input 12 Input 11 Input 10 Input 15 Input 13 Input 11 Input 9 Input 8 Input 9 Input 7 Input 5 Input 3 Input 1 FE - 3 2 1 0 3 2 1

Size: 32, Motor Mounting: D (In-line Type), Motor Type: Step Motor, Servo/24 VDC, Lead: C (LEY25, 3; LEY32, 4), Stroke: 500mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 5m, Controller Type (LEC, JXC): 6P (LECA6, Step Data Input Type, PNP), I/O Cable Length for LEC: 5 (5m), Controller Mounting: D (DIN Rail Mounting), Communication

Size: 32, Motor Mounting: D (In-line Type), Motor Type: Step Motor, Servo/24 VDC, Lead: C (LEY25, 3; LEY32, 4), Stroke: 500mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 5m, Controller Type (LEC, JXC): AP (LECPA, Pulse Input Type, PNP), I/O Cable Length for LEC: 5 (5m), Controller Mounting: Screw Mounting, Communication

Size: 32, Motor Mounting: D (In-line Type), Motor Type: Step Motor, Servo/24 VDC, Lead: C (LEY25, 3; LEY32, 4), Stroke: 500mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 3m, Controller Type (LEC, JXC): w/o Controller, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting, Communication Plug Connector

Size: 32, Motor Mounting: D (In-line Type), Motor Type: Step Motor, Servo/24 VDC, Lead: C (LEY25, 3; LEY32, 4), Stroke: 500mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 1.5m, Controller Type (LEC, JXC): w/o Controller, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting, Communication Plug Connector

Size: 32, Motor Mounting: In-line Type, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 3; LEY32, 4, Stroke: 500mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 5m, Controller Type (LEC, JXC): LECA6, Step Data Input Type, PNP, I/O Cable Length for LEC: 5m, Controller Mounting: DIN Rail Mounting, Communication Plug Connector

Size: 32, Motor Mounting: In-line Type, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 3; LEY32, 4, Stroke: 500mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 5m, Controller Type (LEC, JXC): LECPA, Pulse Input Type, PNP, I/O Cable Length for LEC: 5m, Controller Mounting: Screw Mounting, Communication Plug Connector or

Size: 32, Motor Mounting: In-line Type, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 3; LEY32, 4, Stroke: 500mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 3m, Controller Type (LEC, JXC): w/o Controller, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting, Communication Plug Connector or I/O Cable

Size: 32, Motor Mounting: In-line Type, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 3; LEY32, 4, Stroke: 500mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 1.5m, Controller Type (LEC, JXC): w/o Controller, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting, Communication Plug Connector or I/O

Calculating motor speed conversion example using an actuator with a 20mm lead and 500[mm/sec] speed.

EX245-DX1 2Byte Table 11-3 X0 X1 X2 X3 X4 X5 X6 X7 2 Bit 1 Bit 3 Bit 5 Bit 7 Bit 9 Bit 11 Bit 13 Bit 15 4 Bit 0 Bit 2 Bit 4 Bit 6 Bit 8 Bit 10 Bit 12 Bit 14 72 No.EX##-OMY0006CN 11.5. LED EX245-DX1 LED 0 15 OFF ON Fig. 11-2 EX245-DX1 LED 73 No.EX##-OMY0006CN 11.6.

Y7BA is applicable to "-X5" oil proof type (p.2.2-6). 2.2-1 Wide Opening Air Gripper Series MHL2 Specifications 10 16 20 25 32 40 Bore size (mm) One unit can handle workpieces with various diameters Fluid Air Double acting Action A large amount of gripping force is provided through the use of a double piston mechanism, while maintaining a compact design 0.1 to 0.6 0.15 to 0.6 Operating pressure

Calculating motor speed conversion example using an actuator with a 20mm lead and 500[mm/sec] speed.

Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LEY32DC-100, I/O cable length / communication plug(m): Without I/O cable, Controller/driver mounting method: Screw mounting type

MHF Symbol Specifications/Description Heat resistance (100C) Fluororubber seal Without magnet EPDM for seals, Fluorine grease Fluorine grease MHL -X4 -X5 -X50 -X53 -X63 -X79 -X79A -X81A Refer to How to Select the Applicable Model on page 700. Refer to pages 700 and 701 for the details on effective holding force and allowable overhanging distance.

The X5 option, available for the LEY series in sizes 25 and 32, is a dust and drip proof specification equivalent to IP65. The AC servo motors do not require enclosures, but the scraper and lube-retainer configurations are included. Additionally, the body extrusion includes a vent hole and fitting to balance internal pressure so that dust and water are not drawn in.