Note) 200 V type only. 400 V type is provided with an earth leakage breaker as standard. 20 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) 40 3-phase 380 to 415 VAC (50/60 Hz) HRZ Specifications HRZD Model HRS090-Wl-20-l HRS090-Wl-40-l Cooling method Water-cooled refrigeration Refrigerant R410A (HFC) Refrigerant charge kg 1.15 Control method PID control Ambient temperature1 C 5 to
phase 200 VAC (50 Hz), 3-phase 200 to 230 VAC (60 Hz) -20 3-phase 200 VAC (50 Hz), 3-phase 200 to 230 VAC (60 Hz) -20 3-phase 200 VAC (50 Hz), 3-phase 200 to 230 VAC (60 Hz) -40 3-phase 380 to 415 VAC (50/60 Hz) -40 3-phase 380 to 415 VAC (50/60 Hz) -40 3-phase 380 to 415 VAC (50/60 Hz) Set temp. range 5 to 35C Set temp. range 5 to 35C Set temp. range 5 to 35C Temp. stability 0.1C Temp. stability
HRS Output setting example Output 1: Temperature rise Output 2: Pressure rise Output 3: Operation status (start, stop, etc.)
Inscribed number 3 3 x 1 3 3A 1/8" x 1/16" 4 4 x 2 4 4A 5/32" x 1/32" 6 6 x 4 6 6A 1/4" x 1/8" KO Plug connector, Without connector G (Option) Grommet, 300 mm y Lead wire length Nil 300 mm 6 600 mm 10 1000 mm The plug connector is included but does not come assembled.
-15 3.5.1 . 3-15 3.5.2 . 3-16 3.5.3 . 3-17 3.5.4 . 3-17 3.6 . 3-18 3.6.1 (SS1) . 3-18 3.6.2 . 3-19 3.6.3 . 3-20 3.6.4 EM2 . 3-20 3.7 . 3-21 3.7.1 . 3-21 3.7.2 . 3-22 3.8 . 3-23 3.8.1 . 3-23 3.8.2 . 3-24 3.8.3 . 3-26 1- 3.9 SSCNET . 3-27 3.10 . 3-29 3.10.1 . 3-29 3.10.2 . 3-30 3.11 . 3-34 4 41 4-18 4.1 . 42 4.1.1 . 42 4.1.2 . 43 4.1.3 . 45 4.2 . 45 4.3 . 47 4.3.1
Transportation using forklift and hanging . 3-2 3.1.2 Transportation using casters . 3-3 3.2 Installation . 3-4 3.2.1 Environment . 3-4 3.2.2 Location . 3-6 3.2.3 Installation and maintenance space . 3-7 3.3 Installation . 3-8 3.3.1 Installation . 3-8 3.3.2 Electrical wiring .3-10 3.3.3 Preparation and wiring of power supply cable .3-12 3.3.4 Contact input/output communicatin wiring .3-17
times each Impact resistance Noise resistance 1000Vp-p, Pulse width 1s, Rise time 1ns Weight Note 3) 410g 470g 650g 1,100g Port size (Rc, NPT, G) 3/8 3/8, 1/2 1/2, 3/4 3/4, 1 Note 1) The system accuracy when combined with PF2W3.
times each Impact resistance Noise resistance 1000 Vp-p, Pulse width 1 s, Rise time 1 ns Weight Note 3) 660 g Port size (Rc, NPT, G) 1/2, 3/4 3/8, 1/2 3/8 Note 1) The system accuracy when combined with PF2W3.
410 g 470 g 650 g 1,100 g Port size (Rc, NPT, G) 3/8 3/8, 1/2 1/2, 3/4 3/4, 1 Note 1) The system accuracy when combined with PF2W2/3.
Flow control of cooling water for welding gun Fluid Vortex generator Vortex detector For Water Series variations Model Measured flow range l/min (SCFM) Output specifications Port size 2 to 16 (0.07 to 0.56) 5 to 40 (6.18 to 1.41) 0.5 to 4 (0.02 to 0.4) NPN PNP Rc 3/8 1/2 3/4 3/4 3/4 NPT 3/8 1/2 G 3/8 1/2 New PFW704 Integrated display type PFW720 New PFW740 PFW300 New PFW310 New PFW320 Display
8 8 63 80 90 59 59 62 104 (116) 118 (136) 133 (150) 26 32.5 36.5 71 87 97 14 17.5 20 92 92 95 3 8 1 2 3 4 1 VXP2152 VXP2262 VXP2150 VXP2260 ( ): N.O. 17-3-50 9 Series VXP21/22/23 Pilot Operated 2 Port Solenoid Valve For Air, Gas, Steam and Oil The VX series will be revised shortly.
LQ Hexagon width across flats Bracket 2-Rc , , 4 1 8 3 2 1 LVN TI/ TIL Conduit terminal: T PA PAX PB Bracket 2-Rc , , 4 1 8 3 2 1 : Port size Rc 1/2 17-3-39 8 The VX series will be revised shortly.
/ Material 17-3-101 The VX series will be revised shortly. Series VX Applicable Fluids Check List 3 Port Direct Air Operated Series VXA31/32 Common (C.O.) Refer to pages 17-3-54 and 17-3-55 for specifications and models.
Refer to pages 17-6-3 to 17-6-10 for Safety Instructions and Solenoid Valve Precautions. 17-3-62 3 Series VXZ22/23 Pilot Operated 2 Port Solenoid Valve For Zero Pressure Differential Operation The VX series will be revised shortly. N.C.
cores x 14 AWG (2.0 mm2), 3 m Electrical system Applicable earth leakage breaker capacity Note 7) A 15 Rated operating current (50/60 Hz) Note 3) A 7.1/7.8 For option -T: 7.8/8.4 7.1/7.8 For option -T: 7.8/8.4 Rated power consumption (50/60 Hz) Note 3) kVA 0.53/0.54 For option -T: 0.62/0.62 0.63/0.63 For option -T: 0.72/0.72 Dimensions Note 8) mm W377 x D435 x H615 For option -T: W377 x D500