mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Contact input signal 2 Circuit diagram 4 1 k 11 Run/stop signal input Contact input signal 1 4.7 k 3 1 k Internal circuit 10 Alarm status signal output
heat C [cal/(kgfC)] 41F (5C) 1.00 4.2 x 103 1.00 1 x 103 1.02 3.91 x 103 1.02 0.93 x 103 1.02 3.91 x 103 1.02 0.93 x 103 50 (10) 1.00 4.19 x 103 1.00 1 x 103 1.01 3.91 x 103 1.01 0.93 x 103 59 (15) 1.00 4.19 x 103 1.00 1 x 103 1.01 3.91 x 103 1.01 0.93 x 103 68 (20) 1.00 4.18 x 103 1.00 1 x 103 1.01 3.91 x 103 1.01 0.94 x 103 77 (25) 1.00 4.18 x 103 1.00 1 x 103 1.01 3.91 x 103 1.01 0.94
Length 3 3 x 1 6 600 mm 10 1000 mm 3A 1/8" x 1/16" 4 4 x 2 4A 5/32" x 1/32" 6 6 x 4 6A 1/4" x 1/8" 100 mm Specifications Model LPV21 LPV22 Valve type N.C. N.O.
silencer) ZH05B 6/Rc 1 8 6/Rc 1 8 ZH07B ZH10B ZH13B ZH05D ZH07D ZH10D ZH13D ZH15D ZH18D ZH20D 12/Rc 3 8 Body ported type (Without silencer) 8/Rc 1 8 10/Rc 1 4 6/Rc 1 8 6/Rc 1 8 6/Rc 1 8 6/Rc 1 8 6/Rc 1 8 8/Rc 1 8 8/Rc 1 8 10/Rc 1 4 10/Rc 1 4 3 8 12/Rc 10/Rc 1 4 12/Rc 3 8 12/Rc 3 8 16/Rc 1 2 16/Rc 1 2 13-5-2 3 Series ZH Vacuum Ejector: Box Type (Built-in Silencer)/Body Ported Type Ejector
(2) (10.2) 50 [ms] 40 30 T8 T9 20 T7 10 T6 T5 0 0 1000 2000 3000 4000 5000 6000 [r/min] LE-T10.3.2 [] LE-T5LE-T6LE-T730 LE-T8LE-T910 6 10. 10.4 a 1 10 8 5 10 7 1 10 7 5 10 6 a: [ms] 1 10 6 5 10 5 b: SSCNET 1 10 5 5 10 4 1 10 4 b 5 10 3 1 10 3 4 7 10 20 40 70 100 200 [mm] 10.5 2500kVA1mAC240V()LECSS2T5LECSS2-T9AC200V (A0-P) (L1L2L3) (L11L21) LECSS2-T5LECSS2-T7 LECSS2-T8
[mm] *1 D1 Weight [g] With a rib X (X) Y Nylon Urethane Applicable tubing M L1 Oval type Round type 4 1/8 KQ2L04-01GS1 10 8.2 7.7 10 10 14.8 16.2 17.2 13.3 4.6 3.3 3 4.8 1/4 KQ2L04-02GS1 14 8.2 7.7 10 10 14.8 21.7 21.1 13.3 4.6 3.3 3 14.3 Rib 4, 6 8 to 16 6 1/8 KQ2L06-01GS1 10 10.4 9.7 12 10 15.5 17.3 19.4 13.3 11.4 9 4.5 5.2 1/4 KQ2L06-02GS1 14 10.4 9.7 12 10 15.5 22.8 23.3 13.3 11.4
535 1 5 10 20 50 1 5 10 20 50 16-11-13 10 For details about certified products conforming to international standards, visit us at www.smcworld.com.
PF2W504--1 PF2W520--1 PF2W540--1 PF2W511--1 PF2W504--2 PF2W520--2 PF2W540--2 PF2W511--2 4 0.5 4 0.5 16 2 16 2 40 5 40 5 100 10 100 10 19 Series PF2W For Water Digital Flow Switch to are terminal numbers.
temperature C 2 to 45 Circulating fluid CH1 : Clear water / CH2 : Clear water,DI water (pure water) 1 Set temperature range C CH1 : 15 to 25 / CH2 : 20 to 40 Cooling capacity2 kW 9 1 8 19 1 8 26 1 8 Heating capacity3 kW 1.5 1 4.5 1 6.5 1 Temperature stability 4 C CH1 0.1 CH2 0.5 Rated flow rate (Outlet) L/min 45 10 45 10 125 10 (0.43MPa) (0.45MPa) (0.45MPa) (0.45MPa) (0.45MPa) (0.45MPa
Q = qm x C x (T2 T1) r x qv x C x iT 60 = 1 x 10 x 4.2 x 103 x 2.0 60 = Q = qm x C x (T2 T1) 860 = 1400 [J/s] 1400 [W] g x qv x 60 x C x iT 860 = Cooling capacity = Considering a safety factor of 20%, 1400 [W] x 1.2 = 1680 [W] 1 x 10 x 60 x 1.0 x 103 x 2.0 860 = qv: Circulating fluid flow rate Q: Heat generation amount Users equipment T2: Return temperature 120 [cal/h] 860 = Thermo-chiller
Real-time switch output Hysteresis mode Unit switching ON YES OFF P-1 P-2 For Air Instantaneous flow rate Display Instantaneous flow rate Accumulated flow "P" Window comparator mode H : Hysteresis L/min L CFM x 10-2, CFM x 10-1 ft3 x 10-1 H H ON CFM = ft3/min NO OFF P-1 P-2 High Flow Rate Type (For Air) Instantaneous flow rate OUT1 Output mode Display Instantaneous flow rate Accumulated
10 5 (2) 10 (1) Note 1) Dew point: 10C or less Note 2) 50 cSt or less Note 3) D, E etc. in parentheses are option symbols.
Panel adapter B ZS-22-02 Thread type Piping port size Rc NPT G Nil N F 01 02 1/8 1/4 Specifications PFA301-m PFA300-m Model Specifications Note 1) 1 to 10, 5 to 50l/min (0.04 to 0.35, 0.18 to 1.77SCFM) Flow rate range measurement & setting Minimum setting unit 1% of maximum flow rate range Model PFA510-m PFA550-m Real-time flow rate l/min, CFM x 10-2 Display units Measured fluids Dry air,
80 60 10(1) 60 40 40 60 Maximum Minimum 10 5(2) Note 1) Dew point: 10C or less Note 2) 50 cSt or less Note 3) D, E, N, P etc. in parentheses are option symbols.
80 60 10 60 40 1 AC DC AC/DC Maximum 10 (1) 5 (2) Minimum Note 1) Dew point is below 10C Note 2) Below 50 cSt Note 3) D, E, N, P, etc. in parentheses represents option symbol.
Power consumption Temperature rise 4 W type 5C 10 W type 14C Required time for attachment/detachment: Approx. 5 seconds (per unit) Reduces installation time for multiple numbers of valves. During continuous operation at 24 VDC, 0.25 MPa, 300 Hz Filter is mounted to port 1 (IN). Filter is mounted to port 1 (IN) for quick disconnect type as well.
Port size 04 06 10 12 14 20 LVH 1 2 3 4 Refer to page 17-3-16 for ordering coil only. 1 1 1 2 LVD 1 4 1 2 Thread type Nil T F N LVQ Rc NPTF G NPT Refer to the table (1) given below for availability.
IN MaterialO Model Body Seal Brass, Stainless steel NBR, FPM, EPR Orifice size (mm) Model Port size Rc(PT) VXA212 , 1 8 1 4 , 1 8 1 4 , 1 4 3 8 , 1 4 3 8 , 1 4 3 8 , 1 4 , 3 8 1 2 0 2 3 4.5 VXA213 0 2 VXA223 0 2 4.5 6 8 VXA224 0 2 VXA225 0 2 10 VXA226 0 2 4.1-57 VXA21/22 Normally Closed (N.C.)/Normally Open (N.O.)
Insulation oil A H Polyacetal Note 1) Note 1) Non-leak (10 6 Pam 3/s) Brake oil Water (up to 60C) B P A H Stainless steel Note 1) If using for other fluids, please contact SMC.
Temperature conditions Water (Standard) Air (Standard) Oil (Standard) Vacuum (3) (V, M) Maximum Minimum 40 1 60 5(1) 40 5 40 40 5 5(2) Pilot port Note 1) Dew point: 5C or less Note 2) 500 cSt or less Note 3) V, M in parentheses are option symbols.