This is a legacy product, and replaced byCJ2D16-30AZ, CYL, RND BODY, D/CLVS, D/ACT, ACTUATOR, CJ2 ROUND BODY CYLINDER, GD, 16MM CJ2 DOUBLE-ACTING, .24017 lb, SeriesDescriptionModelActionNoteVol. no. (for std model)CJ2Air cylinderCJ2Double acting, Single rodExcept with air cushion666
The new style MGP has a shorter guide rod and thinner plate resulting in a weight reduction of up to 17% over the original MGP. The series is designed for high side load applications found in material handling, lifting and stopping. The cylinder utilizes an ultra-compact design by incorporating the cylinder body as part of the guide body. As the stroke length increases, so does the bearing
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number
Bearing Type: M (Slide Bearing), Bore Size: 25mm, Thread Type: Rc; Bore Size 12, 16: M5 x 0.8, Stroke: 30mm, Stroke Adjustment: A (0 to 10), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: XC9 (Adjustable Stroke, Retraction Type)
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number
Bearing Type: Slide Bearing, Bore Size: 25mm, Thread Type: Rc; Bore Size 12, 16: M5 x 0.8, Stroke: 30mm, Stroke Adjustment: 0 to 10, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Adjustable Stroke, Retraction Type
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: M9PV, Lead Wire Length(m): 5, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: M9PV, Lead Wire Length(m): 5, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: NPT, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: NPT, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: M5 x 0.8, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: G, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: M5 x 0.8, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: M5 x 0.8, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: NPT, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: G, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number