SMC Corporation of America
Elite Part Number Search
Search Results "MHQG2-32C"

the capacities of CH1 and CH2. * The ambient temperature of 32C is at 60% fan output (default setting). * The ambient temperatures of 40C and 45C are at 100% fan output.

0 10 20 30 40 Circulating fluid temperature [C] Circulating fluid temperature [C] HRR030-A-20, HRR030-W-20 [50 Hz] [60 Hz] 4000 4000 25C 25C 3500 3500 Cooling capacity [W] Cooling capacity [W] 3000 3000 32C 2500 2500 32C 2000 2000 40C 1500 1500 40C 1000 1000 Ambient temperature or facility water temperature Ambient temperature or facility water temperature Ambient temperature or facility

temperature 32C Facility water temperature 32C 25 25 Cooling capacity [kW] Cooling capacity [kW] 20.5 20.6 Ambient temperature 43C 20 20 15 15 Ambient temperature 45C Facility water temperature 40C 10 10 5 5 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [C] Circulating fluid temperature [C] HRSH250-A-20/40HRSH250-W-20/4030 30 Ambient temperature 32C Facility water

Deionized water: Electric conductivity 1 mS/cm or higher (Electric resistivity 1 MWcm or lower) Note 3) q Facility water temperature: 32C, w Circulating fluid: Tap water, e Circulating fluid temperature: 20C, r Circulating fluid flow rate: Rated flow, t Power supply: 200 VAC Note 4) q Facility water temperature: 32C, w Circulating fluid: Tap water, e Circulating fluid flow rate: Rated flow

Deionized water: Electric conductivity 1 mS/cm or higher (Electric resistivity 1 MWcm or lower) Note 3) q Ambient temperature: 90F (32C), w Circulating fluid: Tap water, e Circulating fluid temperature: 68F (20C), r Circulating fluid flow rate: Rated flow, t Power supply: 200 VAC Note 4) q Ambient temperature: 90F (32C), w Circulating fluid: Tap water, e Circulating fluid flow rate: Rated

temperature: 32C, w Circulating fluid: Tap water, e Circulating fluid flow rate: Rated flow, r Power supply: 200 VAC 4 q Ambient temperature: 32C, w Circulating fluid: Tap water, e Circulating fluid temperature: CH1 20C/CH2 25C, r Load: Same as the cooling capacity, t Circulating fluid flow rate: Rated flow, y Power supply: 200 VAC, u Piping length: Shortest 5 With the pressure control

Deionized water: Electric conductivity 1 mS/cm or higher (Electric resistivity 1 MWcm or lower) 3 q Ambient temperature: 32C, w Circulating fluid: Tap water, e Circulating fluid temperature: 20C, r Circulating fluid flow rate: Rated flow, t Power supply: 200/400 VAC 4 q Ambient temperature: 32C, w Circulating fluid: Tap water, e Circulating fluid flow rate: Rated flow, r Power supply: 200

Cooling Capacity HRSH090-A-20HRSH090-A-4012 12 Ambient temperature 32C Ambient temperature 32C 10 10 Cooling capacity [kW] Cooling capacity [kW] 8 8 Ambient temperature 43C Ambient temperature 43C 6 6 Ambient temperature 45C 4 4 Ambient temperature 45C 2 2 0 0 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 Circulating fluid temperature [C] Circulating fluid temperature [C] HRSH090-W-20/4014

Rc1 Weight [kg] 16 17 18 22 23 27 28 46 Coating color Body panel: White 1 Base: Gray 2 Applicable air compressor output [kW] (Reference) For screw type 0.75 1.5 2.2 3.7 5.5 7.5 11 15 Refrigerant R134a (HFC) IDU E *1 Air flow capacity under the standard condition (ANR) [20C, Atmospheric pressure, and 65% Relative humidity] *2 Air flow capacity converted by the compressor intake condition [32C

Conditions: Air pressure 0.7 MPa, Ambient temperature 32C. Inlet air temperature 50C is saturated air. At 70C or more, it is humid air with dew point 67C. Flow Characteristics Air pressure 0.7 MPa (Example) To get pressure drop at 0.3 MPa of air pressure, 2000 l/min (ANR) of air flow, and model HAA22, use P = 0.0007 MPa from the table and convert P1 to 0.3 MPa.

:32C,(2) Circulating fluid: Clean water, (3) Circulating fluid temperature: CH1 20C /CH2 25C, (4) Load: Refer to the specified cooling capacity, (5) Circulating fluid flow rate: Rated flow rate, (6) Power supply: 400 VAC, (7) Piping length: Minimum 5 With the pressure control mode that controls the pressure automatically with the inverter.If the pressure control mode is not necessary,use

New Products Guide 1 Directional Control Valves Actuators Vacuum Equipment CAT.E00-6A INDEX New Products Guide 1 Directional Control Valves 5 Port Solenoid Valve Fieldbus System (For Input/Output) 2/3 Port Mechanical Valve Series SY3000/5000/7000 Series EX600 Series VM100/200 P .6 P .264 P .322 Actuators Foot Pedal Type 5 Port Mechanical Valve XT34-60/67 Air Cylinder Air Cylinder Series CJ2

Double energy saving function series Load factor (%) 0 100 Energy saving design 76% reduced Power consumption By up to By up to (1 kW) 1 1.Operating conditions: The IDF125FS operated in the energy saving operation mode Ambient temperature 90F (32C) Inlet air temperature 104F (40C) Inlet air pressure 102 psi (0.7 MPa) Air flow rate = Rated flow x 0.4 Power supply frequency 60 Hz Power supply

temperature: 32C, Outlet air temperature: 10C IDF55C 3825 4500 IDF37C1 2600 3050 50Hz 60Hz Model IDU6D IDU8D IDU11C IDU15C IDU22C1 IDU37C1 IDU55C IDU75C A 309 309 307 357 369 419 417 463 A 309 309 307 357 349 399 397 447 464 464 526 690 Model IDF6D IDF8D IDF11C IDF15C IDF22C1 IDF37C1 IDF55C IDF75C IDF120D IDF150D IDF190D IDF240D C Anti-corrosive treatment Option symbol Drain discharge port

Water cooled aftercooler Inlet air temperature: 180C Inlet temperature of cooling water: 30C Note 2) Series IDF Inlet air temperature: Saturated at 35C (IDF1D), saturated at 40C (IDF2D to 240D), Ambient temperature: 32C Note 3) Series IDG Inlet air temperature: Saturated at 25C, Ambient temperature: 25C Note 4) Series IDU Inlet air temperature: 60C (IDU3D to 6D), 55C (IDU8D to 37C1), 50C

Symbol Weight 18 22 23 27 28 46 (kg) AM Body panel: White 1 Base: Gray 2 Coating color Refrigerated air dryer AMD EC Directive (with CE marking) Compliant standards Auto drain Note 1) Air flow capacity under the standard condition (ANR) [atmospheric pressure at 20C, relative humidity at 65%] Note 2) Air flow capacity converted by the compressor intake condition [atmospheric pressure at 32C

Maximum Flow Capacity of the Compressor Intake Condition under Rated Conditions Model AFF70D AFF80D AFF90D Maximum flow capacity/Compressor intake condition*2 [m3/min] 7.3 11.5 15.1 *1 Flow at 20C, atmospheric pressure, and 65% of relative humidity *2 32C, flow rate when converted to atmospheric pressure *3 Filtration efficiency for the conditions below in addition to the rated conditions

25C, (4) Circulating fluid flow rate: Rated flow rate, (5) Power supply: 200 VAC 3 (1) Facility water temperature:32C,(2) Circulating fluid: Clean water, (3) Circulating fluid flow rate: Rated flow rate,(4)Power supply: 200 VAC 4 (1) Facility water temperature:32C,(2) Circulating fluid: Clean water, (3) Circulating fluid temperature: CH1 20C /CH2 25C, (4) Load: Refer to the specified cooling

Clean water, (3) Circulating fluid temperature: CH1 20C /CH2 25C, (4) Circulating fluid flow rate: Rated flow rate, (5) Power supply: 400 VAC 3 (1) Facility water temperature:32C,(2) Circulating fluid: Clean water, (3) Circulating fluid flow rate: Rated flow rate,(4)Power supply: 400 VAC 4 (1) Facility water temperature:32C,(2) Circulating fluid: Clean water, (3) Circulating fluid temperature

: 32C, w Circulating uid: Tap water, e Circulating uid ow rate: Rated ow, r Power supply: 200 VAC 4 q Ambient temperature: 32C, w Circulating uid: Tap water, e Circulating uid temperature: CH1 20C/CH2 25C, r Load: Same as the cooling capacity, t Circulating uid ow rate: Rated ow, y Power supply: 200 VAC, u Piping length: Shortest 5 With the pressure control mode by inverter.