Cooling Capacity: 030 (Cooling Capacity: 2600/3200W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: JT (J + T)

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 2600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Pressure(MPa): -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: NPT, Auto

Louis Tel: (314) 439-8900 Fax: (314) 439-8901 Atlanta Tel: (770) 624-1940 Fax: (770) 624-1943 Boston Tel: (603) 610-2500 Fax: (603) 610-2600 Charlotte Tel: (704) 947-7556 Fax: (704) 947-8556 Nashville Tel: (615) 331-0020 Fax: (615) 331-9950 New Jersey Tel: (732) 537-0122 Fax: (732) 537-0421 Richmond Tel: (804) 527-0500 Fax: (804) 527-2100 Rochester Tel: (585) 381-3890 Fax: (585) 381-3941

Magnet: None, Mounting: B (Basic), Cushion: N (Rubber Bumper), Bore Size: 50 (2"), Stroke: 2600 (26")

Theoretical Output Unit: N Operating pressure (MPa) Bore size (mm) Rod size (mm) Operating direction Piston area (cm2) 0.3 0.5 0.7 1.0 182 300 418 600 6 R 32 16 243 400 557 800 8 H 319 525 731 1050 10.5 R 40 16 380 625 870 1250 12.5 H 502 825 1149 1648 16.5 R 50 20 596 980 1365 1961 19.6 H 780 1300 1820 2600 26 R 63 25 948 1560 2172 3121 31.2 H Note) Theoretical output (N) = Pressure (MPa

944-1870 Austin Tel: (512) 926-2646 Fax: (512) 926-7055 Dallas Tel: (972) 446-1140 Fax: (972) 446-1251 Los Angeles Tel: (714) 669-1701 Fax: (714) 669-1715 Phoenix Tel: (480) 967-2570 Fax: (480) 829-0824 Portland Tel: (503) 644-1696 Fax: (503) 644-4041 San Jose Tel: (408) 943-9600 Fax: (408) 943-9111 Atlanta Tel: (770) 624-1940 Fax: (770) 624-1943 Boston Tel: (603) 610-2500 Fax: (603) 610-2600

Rotary table w/external shock absorber, Four bore sizes available, High precision or basic type available, 90 and 180 rotation available, Auto switch capable, Rotary Table, ROTARY ACTUATOR, 2600 lb

This is a legacy product, and replaced byNCA1D200-2600-X142US

method Air-Cooled refrigerated type Water-Cooled refrigerated type Refrigerant R407C(HFC) Quantity of refrigerant kg 0.57 0.5 Control method PID control Ambient temperature and humidity2 Temperature: 5 to 40oC Humidity: 30 to 70% Circulating fluid3 Tap water, Ethylene glycol aqueous solution 15%5 Operating temperature oC 5 to 40 range2 Circulating fluid system Cooling capacity4 (50/60Hz) W 2600

Air slide table w/built-in guide rail, Bore size *: 6, 8, 12, 16, 20, 25, Standard or symetric styles, Adjuster options: rubber stopper, shock absorber, metal stopper, Auto switch capable, Cyl, Slide Table, GUIDED CYLINDER, D77, 2600 lb

shock absorber 510 940 1230 2010 2890 4100 7650 Basic With external shock absorber Type 90 specification 600 1150 1460 2390 180 specification 570 1090 1390 2280 [g] Size 10 20 30 50 With adjustment bolt 530 1040 1350 2150 With internal shock absorber 540 1040 1350 2170 High precision With external Shock absorber 90 specification 670 1340 1690 2720 type 180 specification 640 1290 1620 2600

650 750 IDF15C 1025 1200 50Hz 60Hz (131) (68) Motor operated auto drain Model Air flow capacity (l/min (ANR)) 50/60Hz IDF22C1 1575 1850 IDF75C 5250 6200 [Condition IDF1D] Pressure: 0.7MPa, Saturation: 35C Ambient temperature: 32C, Outlet air temperature: 10C [IDF2D to 75C] Pressure: 0.7MPa, Saturation: 40C, Ambient temperature: 32C, Outlet air temperature: 10C IDF55C 3825 4500 IDF37C1 2600

Air slide table w/built-in guide rail, Bore size *: 6, 8, 12, 16, 20, 25, Standard or symetric styles, Adjuster options: rubber stopper, shock absorber, metal stopper, Auto switch capable, Cylinder, Slide Table, GUIDED CYLINDER, 2600 lb

Cooling Capacity: Cooling Capacity: 2600/3200W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: B + M + T

Cooling Capacity: Cooling Capacity: 2600/3200W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: B + T

Cooling Capacity: Cooling Capacity: 2600/3200W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: J + T

Cooling Capacity: Cooling Capacity: 2600/3200W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: Rc, Option: M [Applicable to DI Water (Deionized Water) Piping]

Cooling Capacity: Cooling Capacity: 2600/3200W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: B + J + M

Cooling Capacity: Cooling Capacity: 2600/3200W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: B + M + T