Cylinder speed 1000 mm/sec. Sequencer response time 0.1 sec. Detecting point dispersion Within 100 mm (= 1000 mm/sec. x 0.1 sec.) Take PLC response time into consideration when using.

Cylinder speed 1000 mm/sec. Sequencer response time 0.1 sec. Detecting point dispersion Within 100 mm (= 1000 mm/sec. x 0.1 sec.) Take PLC response time into consideration when using.

Cylinder speed 1000 mm/sec. Sequencer response time 0.1 sec. Detecting point dispersion Within 100 mm (= 1000 mm/sec. x 0.1 sec.) Take PLC response time into consideration when using.

20 ~ 1000 32 35 70 52 20 40 17 17 M 8 x 1.25 7 11 M 18 x 1.5 30 3/8 90 0 63 ~ 1000 20 ~ 1000 32 35 85 64 20 40 17 17 M 10 x 1.25 7 14 M 18 x 1.5 31 3/8 98 0 80 ~ 1000 20 ~ 1000 37 40 102 78 25 52 21 21 M 12 x 1.75 11 17 M 22 x 1.5 37 1/2 116 0 100 ~ 1000 20 ~ 1000 37 40 116 92 30 52 21 21 M 12 x 1.75 11 17 M 26 x 1.5 40 1/2 126 0 Without gaiter With gaiter Bore Size (mm) FV FD FT FX FY FZ

Cylinder speed 1000 mm/sec. Sequencer response time 0.1 sec. Detecting point dispersion Within 100 mm (= 1000 mm/sec. x 0.1 sec.) Take PLC response time into consideration when using.

20 ~ 1000 32 35 70 52 20 40 17 17 M 8 x 1.25 7 11 M 18 x 1.5 30 3/8 90 0 63 ~ 1000 20 ~ 1000 32 35 85 64 20 40 17 17 M 10 x 1.25 7 14 M 18 x 1.5 31 3/8 98 0 80 ~ 1000 20 ~ 1000 37 40 102 78 25 52 21 21 M 12 x 1.75 11 17 M 22 x 1.5 37 1/2 116 0 100 ~ 1000 20 ~ 1000 37 40 116 92 30 52 21 21 M 12 x 1.75 11 17 M 26 x 1.5 40 1/2 126 0 Without gaiter With gaiter Bore Size (mm) FV FD FT FX FY FZ

Graph (3) 20 x 9.8 x (0.07 + 0.05) x 10/1000 = 0.24 20 x 9.8 x (m1 + m2) x H/1000 0.24 Nm < Effective torque OK < Effective torque (Nm) Find the moment of inertia, "IR" for the load + attachments (2 pcs.) 7 IR = K x (a2 + b2 + 12h2) x (m1 + m2)/(12 x 106) IR = 2 x (202 + 302 + 12 x 102) x (0.07 + 0.05)/(12 x 106) = 0.05 kgm2 (K = 2: Safety factor) Kinetic energy 8 Confirm that the kinetic

Cylinder speed 1000 mm/sec. Sequencer response time 0.1 sec. Detecting point dispersion Within 100 mm (= 1000 mm/sec. x 0.1 sec.) Take PLC response time into consideration when using.

) (900) (1000) (900) (1000) (1000) MY1C20 MY1C20 MY1C20 MY1C20 MY1C16 MY1C16 MY1C16 MY1C16 MY1C16 MY1C16 (900) (900) 20 10 0 1000 2000 3000 5000 4000 Support spacing (l ) (mm) 8-11-65 63 Series MY1C Construction: 16 to 63 $1 #3 !

) 10 100 Load weight (kg) 10 80 m 63 50 1000 40 32 10 100 100 1000 Speed (mm/s) Series CH2G, CH2H: Load weight for horizontal motion Speed chart (C-rod retraction, pressure 14MPa) 10 100 Load weight (kg) 10 80 63 50 m 1000 40 10 100 100 1000 Speed (mm/s) Series CH2G, CH2H: Load weight for horizontal motion Speed chart (extension, pressure 14MPa) 10 Load weight (kg) 100 10 80 63 m 50 1000

/D-A93/D-A96 OUT () Blue Blue D-A96(V) Indicator light DC (+) Brown LED diode M2.5 x 4l Slotted set screw D-A90 type comes without indicator light (+) Resistor Load Reed switch DC power supply OUT Black Reverse current prevention diode () DC () Blue Most sensitive position ( ): dimensions for D-A93.

750 20 1500 1000 200, 250, 300, 350, 400, 450 500, 600, 700, 800 25 2000 1500 32 High Precision Guide Type REAH 200, 250, 300, 350, 400, 450 500, 600, 700, 800, 900, 1000 40 2000 1500 Note) Intermediate strokes can be arranged in 1mm increments.

Note 4) The stroke range with rod boot is up to 1000 mm. Please consult with SMC when exceeding 1000 mm strokes.

style (D-A73C/A80C) and A9/A9 V style: 1000 V AC/min.

MHF Type Solid state switch Reed switch 3-wire: 100 A or less, 2-wire: 0.8 mA or less (4) Leakage current None MHL Note 2) Operating time 1 ms or less (3) 1.2 ms Impact resistance 1000 m/s2 300 m/s2 MHR 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance Note 3) MHK 1000 VAC for 1 minute (Between lead wire and case) 1500 VAC for 1 minute (1) (Between lead wire and

MHF Type Solid state switch Reed switch 3-wire: 100 A or less, 2-wire: 0.8 mA or less (4) Leakage current None MHL Note 2) Operating time 1 ms or less (3) 1.2 ms Impact resistance 1000 m/s2 300 m/s2 MHR 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance Note 3) MHK 1000 VAC for 1 minute (Between lead wire and case) 1500 VAC for 1 minute (1) (Between lead wire and

Cylinder speed-1000 mm/sec. Sequencer response time-0.1 sec. Detecting point despersion-Within 100mm (=1000 mm/sec. X 0.1sec.) Take PLC response time into consideration when using.

20 1000 1500 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700, 800 25 1500 2000 32 40 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700, 800 900, 1000 2000 1500 50 63 Note) Contact SMC if the maximum stroke will be exceeded.

1000 80 80 0 0 2 2000 2000 100 100 0 0 3 4000 2000 70 60 500 1 4 500 2000 60 70 1000 1 5 1000 2000 80 80 0 0 6 2000 1000 80 80 0 0 7 1000 1000 80 80 0 0 8 1000 1000 100 100 0 0 LEC-MR-J3BAT 1000 1000 100 100 0 0 C N 4 ( 3 ) 255 2000 2000 80 80 0 0 RS-422 USB CN 6 CN 1 CN3 CN5 DI/O ON USB CC-Link RS-422 1.

D-A90(V) OUT() Brown Contact protection box CD-P11 CD-P12 Reed switch OUT() Blue Weight (g) D-A93(V) Model D-A90 D-A90V D-A93 D-A93V D-A96 D-A96V LED Brown OUT (+) Brown 41 Lead wire length (m) 0.5 6 6 6 6 8 8 Contact protection box CD-P11 CD-P12 Resistor 3 30 30 30 30 41 Reed switch Zener diode Dimensions (mm) OUT () Blue Blue D-A90/D-A93/D-A96 2 2.8 4.5 2.7 D-A96(V) DC (+) Brown 4 LED