SMC Corporation of America
Elite Part Number Search
Search Results "NCDGKGN25-0100"

Magnet: Built-in, Type: Non-rotating, Mounting: Rear Flange, Cushion: Rubber Bumper, Bore Size: 1 Inch, Stroke: 10 Inch, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Type: Non-rotating, Mounting: Rear Flange, Cushion: Rubber Bumper, Bore Size: 1 Inch, Stroke: 12 Inch, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Type: Non-rotating, Mounting: Rear Flange, Cushion: Rubber Bumper, Bore Size: 1 Inch, Stroke: 5 Inch, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: D (Built-in), Type: K (Non-rotating), Mounting: G (Rear Flange), Cushion: N (Rubber Bumper), Bore Size: 25 (1 Inch), Stroke: 0600 (6 Inch)

Magnet: D (Built-in), Type: K (Non-rotating), Mounting: G (Rear Flange), Cushion: N (Rubber Bumper), Bore Size: 25 (1 Inch), Stroke: 0500 (5 Inch)

Modbus RTU protocol (Hexadecimal notation) Request data 01 08 0 1234 ED7C Response data (normal response) 01 08 0 1234 ED7C (Binary notation) Response data 0001 1000 0 0 0001 0010 0011 0100 1110 1101 0111 1100 Response data (normal response) 0001 1000 0 0 0001 0010 0011 0100 1110 1101 0111 1100 For correspondence between ASCII notation and ASCII hexadecimal notation, refer to the 8.4 ASCII

Example 1) ASCII mode Received function code: 04(0 0100)ASCII code 30h34h Abnormal function code: 84(1000 0100)ASCII code 38h34h Example 2) RTU mode Received function code:04 (0 0100) Abnormal function code:84 (1000 0100) 2) Error Code Assign error code below. 01: Function code of a command is outside the standard. 02: The specified address of register is outside the range. 03: Data field

Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :

Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :

Travel multiplying factor 0300: 1000 0200: 100 0100: 10 0: 1 0010h Current alarm (warning) reading Reads the alarm No. or warning No. occurring currently. 0 0 Occurring alarm No.

Travel multiplying factor 0300: 1000 0200: 100 0100: 10 0: 1 0010h Current alarm (warning) reading Reads the alarm No. or warning No. occurring currently. 0 0 Occurring alarm No.

Example: Part Number *NVSA 4114-52AM =A |NVSA 4114.00A vatve mounled on *ISPA 0112 subplate with a #SPA 0100 Interlace Spaed Control between.

[PA04] = 0100. Set the "PA04" to "0100" in the "Basic" tab. Click on the "Single Axis Write" button. Turn the power OFF and ON again. Parameter is enabled. -24- 6.3.6 Absolute position detection system *If you use the absolute position detection system, set parameter: [PA03]=0001. Refer to "LECSS Operation Manual, chapter 12 for details.

Cylinder (Tube) Inner Diameter(φ): 1", Stroke(mm): 6", Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches: N/A, Type of Auto Switch Mounting: N/A, Custom-made Specifications: None

Cylinder (Tube) Inner Diameter(φ): 1", Stroke(mm): 8", Auto Switches: M9B, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of Auto Switch Mounting: N/A, Custom-made Specifications: None

Magnet: D (Built-in), Type: K (Non-rotating), Mounting: G (Rear Flange), Cushion: N (Rubber Bumper), Bore Size: 25 (1 Inch), Stroke: 0150 (1 1/2"), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in), Type: K (Non-rotating), Mounting: G (Rear Flange), Cushion: N (Rubber Bumper), Bore Size: 25 (1 Inch), Stroke: 0400 (4 Inch), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in), Type: K (Non-rotating), Mounting: G (Rear Flange), Cushion: N (Rubber Bumper), Bore Size: 25 (1 Inch), Stroke: 0400 (4 Inch), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in), Type: K (Non-rotating), Mounting: G (Rear Flange), Cushion: N (Rubber Bumper), Bore Size: 25 (1 Inch), Stroke: 0600 (6 Inch), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in), Type: K (Non-rotating), Mounting: G (Rear Flange), Cushion: N (Rubber Bumper), Bore Size: 25 (1 Inch), Stroke: 0800 (8 Inch), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)