SMC Corporation of America
Elite Part Number Search
Search Results "NCDY2S32H-2500B-A80C"

Magnet: D (Built-in), Bore Size: 32 (1 1/4 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 2500 (25 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: A80--Reed, DC Volt.>5,<24, AC Volt.<100, Lead Wire, Vertical, 0.5M

Magnet: Built-in, Bore Size: 1 1/4 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 25 Inch, Adjuster: Shock Absorber (2 pcs.), Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 0.5M, Number: -

Magnet: Built-in, Bore Size: 1 1/4 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 25 Inch, Adjuster: Shock Absorber (2 pcs.), Auto Switch: A73L--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 3M, Number: -

Magnet: Built-in, Bore Size: 1 1/4 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 25 Inch, Adjuster: Shock Absorber (2 pcs.), Auto Switch: F7PL--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, Horizontal, 3M, Number: -

Magnet: Built-in, Bore Size: 1 1/4 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 25 Inch, Adjuster: Shock Absorber (2 pcs.), Auto Switch: F79--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Horizontal, 0.5M, Number: -

Magnet: Built-in, Bore Size: 1 1/4 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 25 Inch, Adjuster: Shock Absorber (2 pcs.), Auto Switch: F79L--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Horizontal, 3M, Number: -

Magnet: Built-in, Bore Size: 1 1/4 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 25 Inch, Adjuster: Shock Absorber (2 pcs.), Auto Switch: A73H--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, 0.5M, Number: -

Magnet: Built-in, Bore Size: 1 1/4 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 25 Inch, Adjuster: Shock Absorber (2 pcs.), Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 0.5M, Number: 4 pcs.

Magnet: Built-in, Bore Size: 1 1/4 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 25 Inch, Adjuster: Shock Absorber (2 pcs.), Auto Switch: F7PVZ--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, Vertical, 5M, Number: -

Magnet: Built-in, Bore Size: 1 1/4 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 25 Inch, Adjuster: Shock Absorber (2 pcs.), Auto Switch: J79CL--Solid State, Gen. Purpose, 2 Wire, Connector, Vertical, 3M, Number: -

Magnet: Built-in, Bore Size: 1 1/4 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 25 Inch, Adjuster: Shock Absorber (2 pcs.), Auto Switch: F7P--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, Horizontal, 0.5M, Number: -

Magnet: Built-in, Bore Size: 1 1/4 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 25 Inch, Adjuster: Shock Absorber (2 pcs.), Auto Switch: A72HL--Reed, AC Volt.<200, LED, Lead Wire, Horizontal, 3M, Number: 4 pcs.

Magnet: Built-in, Bore Size: 1 1/4 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 25 Inch, Adjuster: Shock Absorber (2 pcs.), Auto Switch: A80--Reed, DC Volt.>5,<24, AC Volt.<100, Lead Wire, Vertical, 0.5M, Number: -

Applicable switch Reed switch D-A7, A80 D-A73C, A80C D-A7H, A80H D-A79W Bore size (mm) D-F7, J79 D-F7V, D-J79C D-F7W, J79W D-F7WV, D-F7BAL D-F7F, D-F7NTL Part No.

With diagnostic output (2-color indication) 4-wire (NPN) 5 V,12 V H7NF F79F V V v v IC circuit 3-wire (NPN equivalent) 5 V A96V A96 A96V A96 V V IC circuit Reed auto switch Yes 200 V A72 A72H V V Grommet 100 V A93V A93 A93V A93 V V V No 100 V or less A90V A90 A90V A90 V V IC circuit Relay, PLC 24 V 12 V 2-wire Yes C73C A73C V V V V Connector No 24 V or less C80C A80C

D-J79C 12 to 25 CUJ CU CQS 32 to 100 CQM CQ2 RQ 40 to 100 D-P5DWL MU D-X 20Data B A U Proper Auto Switch Mounting Position Auto Switch Mounting Height (mm) D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7V/J79C D-F7BAL/F7W D-J79W/F7WV D-F7BAVL/F79F D-A7H, D-A80H D-F7/J79/F7W D-J79W, D-F7BAL D-F79F, D-F7NTL D-F7V D-F7WV D-F7BAVL D-J79C D-A79W D-P5DWL D-A73C D-A80C D-A7 D-A80 D-A79W D-P5DWL D-A7 D-A80

D-A80C without indicator light Note 1) Operating load is an induction load.

Note 2) Dimensions E and F are 7 mm longer for the auto switches with connector (D-A7C/A80C/J79C).

Note D-F7/J79 D-F7V D-J79C D-F7W/J79W D-F7WV D-F7BAL/F7BAVL D-F79F D-F7NTL Switch mounting screw (M3 x 0.5 x 8l ) Square nut 12, 16 20, 25 BQ-1 D-A7/A80 D-A73C/A80C D-A7H/A80H D-A79W Switch mounting screw (M3 x 0.5 x 10l) Switch spacer Switch mounting nut 32, 40 50, 63 80, 100 BQ-2 Switch mounting bracket Switch mounting nut Hexagon hole cap bolt (M3 x 0.5 x 14l spring washer 2 pcs

(mm) Auto switch model Hw 23 Ht Hv D-A7, D-A80 D-F7, D-J79, D-J79W, D-F7W, D-F79F, D-F7BAL, D-F7NTL D-A7H, D-A80H D-A73C, D-A80C D-F7V, D-F7WV, D-F7BAV D-J79C Auto switch model Hw 23 Hs Ht D-A7, D-A80 D-F7, D-J79, D-J79W, D-F7W, D-F79F, D-F7BAL, D-F7NTL D-A7H, D-A80H D-A73C, D-A80C D-F7V, D-F7WV, D-F7BAV D-J79C Note 2) 2 magnets for auto switches are equipped to the magnet mounting block.