SMC Corporation of America
Elite Part Number Search
Search Results "NCGFN20-0100"

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, AIR, ACTUATOR, NCG ROUND BODY CYLINDER, HC, 20MM NCG OTHERS (COMBO), .00000 lb

Magnet: None, Mounting: F (Front Flange), Cushion: N (Rubber Bumper), Bore Size: 20 (3/4"), Stroke A: 0100 (1"), +: None, Stroke B: None, Stroke Adjustment: A (0 to 25mm), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: XC8 (Adjustable Extension Type)

Magnet: None, Mounting: F (Front Flange), Cushion: N (Rubber Bumper), Bore Size: 20 (3/4"), Stroke A: 0100 (1"), +: None, Stroke B: None, Stroke Adjustment: A (0 to 25mm), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: XC9 (Adjustable Retraction Type)

Magnet: None, Mounting: Front Flange, Cushion: Rubber Bumper, Bore Size: 3/4", Stroke A: 1", +: None, Stroke B: None, Stroke Adjustment: 0 to 25mm, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Adjustable Extension Type

Magnet: None, Mounting: Front Flange, Cushion: Rubber Bumper, Bore Size: 3/4", Stroke A: 1", +: None, Stroke B: None, Stroke Adjustment: 0 to 25mm, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Adjustable Retraction Type

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, AIR 3/4 BORE, DUAL STK, ACTUATOR, NCG ROUND BODY CYLINDER, HC, 20MM NCG OTHERS (COMBO), .00000 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, AIR, LOW TEMP, ACTUATOR, NCG ROUND BODY CYLINDER, HC, 20MM NCG OTHERS (COMBO), .00000 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, AIR, 1/4-20 M THD, ACTUATOR, NCG ROUND BODY CYLINDER, HC, 20MM NCG OTHERS (COMBO), .00000 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, AIR, 1/4-20 M THD, ACTUATOR, NCG ROUND BODY CYLINDER, HC, 20MM NCG OTHERS (COMBO), .00000 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL AIR 3/4 BORE SS/ROD, ACTUATOR, NCG ROUND BODY CYLINDER, HC, 20MM NCG OTHERS (COMBO), .00000 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCG ROUND BODY CYLINDER, HS, 20MM NCG SINGLE-ACTING, .00000 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCG ROUND BODY CYLINDER, HS, 20MM NCG SINGLE-ACTING, .00000 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCG ROUND BODY CYLINDER, HD, 20MM NCG DOUBLE-ACTING, .00000 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCG ROUND BODY CYLINDER, HD, 20MM NCG DOUBLE-ACTING, .00000 lb

The NCG provides precision mounting, short overall length, and high speed. Rubber bumpers are standard and an optional adjustable air cushion is available. Nine mounting styles include basic body, foot, single clevis, front or rear flange, front or rear trunnion, nose mount, and double clevis. Bore sizes range from 3/4in. to 2 1/2in. and standard stroke lengths from 1in. to 12in.. The NCG

Magnet: None, Mounting: Front Flange, Cushion: Rubber Bumper, Bore Size: 3/4", Stroke A: 1/2", +: +, Stroke B: 1", Stroke Adjustment: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Dual Stroke, Single Rod

Magnet: None, Mounting: Front Flange, Cushion: Rubber Bumper, Bore Size: 3/4", Stroke A: 1 1/2", +: +, Stroke B: 1", Stroke Adjustment: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Dual Stroke, Single Rod

Modbus RTU protocol (Hexadecimal notation) Request data 01 08 0 1234 ED7C Response data (normal response) 01 08 0 1234 ED7C (Binary notation) Response data 0001 1000 0 0 0001 0010 0011 0100 1110 1101 0111 1100 Response data (normal response) 0001 1000 0 0 0001 0010 0011 0100 1110 1101 0111 1100 For correspondence between ASCII notation and ASCII hexadecimal notation, refer to the 8.4 ASCII

Example 1) ASCII mode Received function code: 04(0 0100)ASCII code 30h34h Abnormal function code: 84(1000 0100)ASCII code 38h34h Example 2) RTU mode Received function code:04 (0 0100) Abnormal function code:84 (1000 0100) 2) Error Code Assign error code below. 01: Function code of a command is outside the standard. 02: The specified address of register is outside the range. 03: Data field