SMC Corporation of America
Elite Part Number Search
Search Results "NCQ2B50-75D-XB6"

Please contact us for the latest version.sales@ocaire.com, NCQ2B50-50S, CDN SPL, ACTUATOR, NCQ2 COMPACT CYLINDER, ND, 50MM NCQ2 DOUBLE-ACTING, 1.38753 lb, SeriesModelActionNoteCQ2StandardCQ2Double acting, Single rodExcept with rubber bumper

Supply pressure cylinder output characteristic measuring circuit CQ2B40-75D (standard) CQ2XB40-75D (microspeed cylinder) Front supply pressure: 0.025MPa Front supply pressure: 0.025MPa 686 686 Test cylinder Load converter 588 588 Theoretical thrust Theoretical thrust 490 490 Analyzing recorder Actual thrust Actual thrust 392 392 Thrust N Thrust N Pressure converter 294 294 196 196 Pressure

Measurement circuit of cylinder output relative to supply pressure CQ2B40-75D (standard) CQ2XB40-75D (microspeed cylinder) Front supply pressure: 0.025MPa Front supply pressure: 0.025MPa 686 686 Test cylinder Load converter 588 588 Theoretical thrust Theoretical thrust 490 490 Analyzing recorder Actual thrust Actual thrust 392 392 Thrust N Thrust N Pressure converter 294 294 196 196 Pressure

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Through hole, Port thread type: Rc, Body Options: Rod End Female Thread, Auto Switches

Magnet: None, Rod Type: Standard, Mounting: B [Through Hole (Standard)], Bore Size: 50mm, Stroke: 75mm

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Through hole, Port thread type: Rc, Body Options: Rod End Female Thread, Auto Switches

Standard strokes (mm) Bore sizes (mm) 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 32, 40 50, 63 80, 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Example) For CQ2XB40-57D, an 18mm spacer is installed inside a standard stroke CQ2XB40-75D cylinder. Specific Product Precautions Be sure to read before handling. Refer to pages 15 to 24 for safety instructions and precautions.

Example) For 10-CQ2XB40-57D, an 18mm spacer is installed inside a standard stroke 10-CQ2XB40-75D cylinder. Manufacturing intermediate strokes Intermediate strokes can be manufactured in 1mm increments by installing spacers in a standard stroke cylinder. The total length of the cylinder is the same as the longer standard stroke.

Magnet: None, Mounting: Through-hole, Standard, Bore Size: 50mm, Stroke: 75mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: w/Heavy Duty Scrapper

Magnet: None, Mounting: Through-hole, Standard, Bore Size: 50mm, Stroke: 75mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: w/Coil Scrapper

Magnet: None, Mounting: Through-hole, Standard, Bore Size: 50mm, Stroke: 75mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: Stainless Steel

Magnet: None, Mounting: B (Standard, Through-hole), Bore Size: 50mm, Stroke 1: 75mm, +: None, Stroke 2: None, Body Option: Standard, Rod End Female Thead, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: XC8 (Adjustable Extension

Magnet: None, Mounting: B (Through-hole, Standard), Bore Size: 50mm, Stroke: 75mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: XC4 (w/Heavy Duty Scrapper)

Magnet: None, Mounting: B (Through-hole, Standard), Bore Size: 50mm, Stroke: 75mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: XC35 (w/Coil Scrapper)

Magnet: None, Mounting: B (Through-hole, Standard), Bore Size: 50mm, Stroke: 75mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: XC6 (Stainless Steel)

Magnet: None, Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 50mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 75mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Mounting Bolt: -, Rod End Bracket: -, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch

Magnet: None, Mounting: Standard, Through-hole, Bore Size: 50mm, Stroke 1: 75mm, +: None, Stroke 2: None, Body Option: Standard, Rod End Female Thead, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Adjustable Extension

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Through hole, Port thread type: Rc, Body Options: Rod End Female Thread, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Through hole, Port thread type: Rc, Body Options: Rod End Female Thread, Auto Switches