ON Time ( ) Terminal block Danger: Connected sensor Terminal block number Accumulated output mode OFF Accumulated flow PF2A30 series PF2A31 series Time 1 2 3 4 DC(-) (for sensor) 1 Function selection mode Operator DC(+) (for sensor) 2 ( ) Accumlated flow PF2A550 PF2A510 PF2A511 PF2A521 PF2A551 3 Sensor input Reverse output Upper 3 digits Lower 3 digits This operation manual is intended for
PF2A550 PF2A511 PF2A521 PF2A551 PF2A510 50 ms OFF No Set value input Item Description Time Connecting / Disconnecting When connecting, insert the connectors straight into the body until it clicks. When removing the connector, press down the lever to release the hook from the housing and pull the connector straight out. Sensor connector socket Socket for the sensor connection.
Flow Range: 0 (PF2A510: 1-10l/min, PF2A550: 5-50l/min), Output Specification: 0 (NPN Open Collector 2 Outputs), Unit: M (S1 Fixed Unit)
Flow Range: 0 (PF2A510: 1-10l/min, PF2A550: 5-50l/min), Output Specification: 0 (NPN Open Collector 2 Outputs)
Flow Range: 0 (PF2A510: 1-10l/min, PF2A550: 5-50l/min), Output Specification: 1 (PNP Open Collector 2 Outputs)
Flow Range: 0 (PF2A510: 1-10l/min, PF2A550: 5-50l/min), Output Specification: 1 (PNP Open Collector 2 Outputs), Unit: M (S1 Fixed Unit)
Flow Range: PF2A510: 1-10l/min, PF2A550: 5-50l/min, Output Specification: NPN Open Collector 2 Outputs, Unit: S1 Fixed Unit
Flow Range: PF2A510: 1-10l/min, PF2A550: 5-50l/min, Output Specification: NPN Open Collector 2 Outputs, Unit: -
Flow Range: PF2A510: 1-10l/min, PF2A550: 5-50l/min, Output Specification: PNP Open Collector 2 Outputs, Unit: -
Flow Range: PF2A510: 1-10l/min, PF2A550: 5-50l/min, Output Specification: PNP Open Collector 2 Outputs, Unit: S1 Fixed Unit
Plug lead unit manifold 2 08 01N VV3Q1
Plug lead unit manifold 2 08 01N VV3Q1
Stations Stasions 3 2 1 Dside Uside 02 2 stations VVQ1000-10A-2 20 20 stations Port size and thread 01N 01T 01F M5, Rc(PT)1/8 NPT1/8 NPTF1/8 G(PF)1/8 Only thread port size 1/8 style (2U type, P/E port) has choice of thread.
Stations U side D side 2 stations 02 VVQ1000-10A-2 Stations4321 20 stations 20 Port size and thread M5, Rc 1/8 NPT 1/8 NPTF 1/8 PF 1/8 Nil 01N 01T 01F Only thread port size 1/8 type, (Type 2U, P/E port) has choice of thread.
Stations U side D side 2 stations 02 VVQ1000-10A-2 Stations4321 20 stations 20 Port size and thread M5, Rc 1/8 NPT 1/8 NPTF 1/8 PF 1/8 Nil 01N 01T 01F Only thread port size 1/8 type, (Type 2U, P/E port) has choice of thread.
Pressure sensor/Vacuum pressure switch mountable Note 1) NIL Sensor/ switch non-mountable base S Sensor/ switch mountable base Note 1) Select S when the model with either the pressure sensor or the pressure switch for vacuum is selected for how-to-order for the single unit (8). (3) Common supply pressure (PV) connecting port size (4) Common vacuum burst pressure (PD) port Note 2) 01 Rc1/8 01N
(Refer to Manifold on page 17.) 12 12 stations Common Release Pressure (PD) Port Size Note) Common Supply (PV) Port Size 01 01N 01F M5 Without PD port (PV = PD) M5 x 0.8 (PV PD) Rc1/8 NPT1/8 G1/8 M5 x 0.8 Nil M5 Note) Refer to on page 1 for the combinations of supply valve and release valve selectable.
This is a legacy product, and replaced byLVA20-01N-A-V-Z, FLUOROPOLYMER, VALVE, VALVE, FLUOROPOLYMER VALVES and REG, 2I, FLUOROPOLYMER, 0.44273 lb
This is a legacy product, and replaced byVT307-5DO1-01N-Q, VT3 BASE MT 1/8, VALVE, VT3/VO3 SOL VALVE 3-PORT, NA, VT3 BASE MT 1/8, 0.34012 lb