--1 PF2A510--2 PF2A550--2 PF2A511--2 PF2A521--2 PF2A551--2 10 50 100 200 500 10 50 100 200 500 1.1 5.4 11 21 54 10.7 53.5 107 214 535 1.1 5.4 11 21 54 10.7 53.5 107 214 535 1 5 10 20 50 1 5 10 20 50 8 For Air Digital Flow Switch/High Flow Rate Type Series PF2A Refer to www.smcworld.com for details of products compatible with overseas standards.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 01 02 03 04 1/8 1/4 3/8 1/2 PF2A510/550 PF2A511/521 PF2A551 Specifications PF2A510 PF2A550 PF2A511 PF2A521 PF2A551 Model Measured fluid Air, Nitrogen Detection type Heater type 20 to 200 l/min 50 to 500 l/min 1 to 10 l/min 5 to 50 l/min 10 to 100 l

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 01 02 03 04 1/8 1/4 3/8 1/2 PF2A510/550 PF2A511/521 PF2A551 Specifications PF2A510 PF2A550 PF2A511 PF2A521 PF2A551 Model Measured fluid Air, Nitrogen Detection type Heater type 20 to 200 l/min 50 to 500 l/min 1 to 10 l/min 5 to 50 l/min 10 to 100 l

--1 PF2A510--2 PF2A550--2 PF2A511--2 PF2A521--2 PF2A551--2 10 50 100 200 500 10 50 100 200 500 1.1 5.4 11 21 54 10.7 53.5 107 214 535 1.1 5.4 11 21 54 10.7 53.5 107 214 535 1 5 10 20 50 1 5 10 20 50 8 For Air Digital Flow Switch/High Flow Rate Type Series PF2A Refer to www.poweraire.com for details of products compatible with overseas standards.

AS121-M5-F04 AS121-M5-F06 AS221-01-F06S AS221-01-F08S AS221-02-F06S AS221-02-F08S AS321-03-F08S AS321-03-F10S AS421-04-F10S AS421-04-F12S 12.7 12.5 33.7 30.7 56.3 52.1 92.9 87.6 153.8 145.5 21 21.5 25.5 26 16 17 17 18.5 17 18.5 18.5 21 21 22 M5 x 0.8 11.2 28.3 8 13 9 25.5 25 22.2 R 1/8 14.7 33.9 36.4 12 15.5 14.6 26.6 31.4 32.4 27.4 R 1/4 17.7 38.5 40.8 17 15.5 19.5 28.7 35.8 34.8 29.8 32.7

New Products Guide 1 Directional Control Valves Actuators Vacuum Equipment CAT.E00-6A INDEX New Products Guide 1 Directional Control Valves 5 Port Solenoid Valve Fieldbus System (For Input/Output) 2/3 Port Mechanical Valve Series SY3000/5000/7000 Series EX600 Series VM100/200 P .6 P .264 P .322 Actuators Foot Pedal Type 5 Port Mechanical Valve XT34-60/67 Air Cylinder Air Cylinder Series CJ2

Bore size (mm) 32 40 50 63 80 100 125 Note 1) MB-L03 MB-L04 MB-L05 MB-L06 MB-L08 MB-L10 MB-L12 Foot MB-F03 MB-F04 MB-F05 MB-F06 MB-F08 MB-F10 MB-F12 Flange MB-C03 MB-C04 MB-C05 MB-C06 MB-C08 MB-C10 MB-C12 Single clevis Double clevis MB-D03 MB-D04 MB-D05 MB-D06 MB-D08 MB-D10 MB-D12 Note 1) Two foot brackets required for one cylinder.

DBore size [mm] 32 40 50 63 80 100 -X Axial foot MB-L03 MB-L04 MB-L05 MB-L06 MB-L08 MB-L10 Rod flange MB-F03 MB-F04 MB-F05 MB-F06 MB-F08 MB-F10 Technical Data Note) Order two foots per cylinder. 413 MBKW Series Theoretical Force OUT (Unit: N) IN Bore size [mm] Rod dia.

PF2A551 12 to 24 VDC Blue DC(-) 22 to 24 Nm Rc(NPT)3/8 PF2W504(T) Piping port Connected to the fluid inlet at IN side and to the fluid outlet at OUT side. 1 5 Rc(NPT)1/2 28 to 30 Nm PF2W520(T) 34 mm Bracket Bracket for mounting the product.

ON Time ( ) Terminal block Danger: Connected sensor Terminal block number Accumulated output mode OFF Accumulated flow PF2A30 series PF2A31 series Time 1 2 3 4 DC(-) (for sensor) 1 Function selection mode Operator DC(+) (for sensor) 2 ( ) Accumlated flow PF2A550 PF2A510 PF2A511 PF2A521 PF2A551 3 Sensor input Reverse output Upper 3 digits Lower 3 digits This operation manual is intended for

PF2A550 PF2A511 PF2A521 PF2A551 PF2A510 50 ms OFF No Set value input Item Description Time Connecting / Disconnecting When connecting, insert the connectors straight into the body until it clicks. When removing the connector, press down the lever to release the hook from the housing and pull the connector straight out. Sensor connector socket Socket for the sensor connection.

Flow Range: 1 (PF2A511: 10-100l/min, PF2A521: 20-200l/min, PF2A551: 50-500l/min), Output Specification: 0 (NPN Open Collector 2 Outputs)

Flow Range: 1 (PF2A511: 10-100l/min, PF2A521: 20-200l/min, PF2A551: 50-500l/min), Output Specification: 0 (NPN Open Collector 2 Outputs), Unit: M (S1 Fixed Unit)

Flow Range: 1 (PF2A511: 10-100l/min, PF2A521: 20-200l/min, PF2A551: 50-500l/min), Output Specification: 1 (PNP Open Collector 2 Outputs)

Flow Range: 1 (PF2A511: 10-100l/min, PF2A521: 20-200l/min, PF2A551: 50-500l/min), Output Specification: 1 (PNP Open Collector 2 Outputs), Unit: M (S1 Fixed Unit)

Sensor 1 L/min 5 L/min 10 L/min 20 L/min 50 L/min 100 L/min 200 L/min 500 L/min Flow rate range 1 L/min 10 L/min PF2A510 0.5 L/min 10.5 L/min 5 L/min 50 L/min PF2A550 52.5 L/min 2.5 L/min 10 L/min 100 L/min PF2A511 105 L/min 5 L/min 20 L/min 200 L/min 210 L/min 10 L/min PF2A521 50 L/min 500 L/min 525 L/min 25 L/min PF2A551 Sensor Flow rate range Static Electricity

Flow Range: PF2A511: 10-100l/min, PF2A521: 20-200l/min, PF2A551: 50-500l/min, Output Specification: NPN Open Collector 2 Outputs, Unit: S1 Fixed Unit

Flow Range: PF2A511: 10-100l/min, PF2A521: 20-200l/min, PF2A551: 50-500l/min, Output Specification: PNP Open Collector 2 Outputs, Unit: -

Flow Range: PF2A511: 10-100l/min, PF2A521: 20-200l/min, PF2A551: 50-500l/min, Output Specification: PNP Open Collector 2 Outputs, Unit: S1 Fixed Unit

AS1201-M5-F04-X12 Ex.) AS1201-M5-F04-X21 Note 1) Not particle-free Note 2) Throttle valve is only compatible with the part no. of the meter-out type. Throttle Valve (Without Check Valve) 3 X214 Ex.)