Rated Flow Range: 0.01 to 1 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/8, Output Specification: Out 1: IO-Link or NPN/PNP, Out 2: Analog 1-5V, Lead Wire: w/M12 Conversion Lead Wire and Connector, 0.1m, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.01 to 1 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/8, Output Specification: Out 1: NPN; Out 2: Analog 4 to 20 mA, Lead Wire: -, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.01 to 1 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/8, Output Specification: Out 1: PNP; Out 2: PNP, Lead Wire: -, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.01 to 1 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/8, Output Specification: Out 1: NPN; Out 2: Analog 4 to 20 mA, Lead Wire: w/o Lead Wire w/Connector, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.01 to 1 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/8, Output Specification: Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V, Lead Wire: -, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.01 to 1 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/8, Output Specification: Out 1: PNP; Out 2: Analog 4 to 20 mA, Lead Wire: -, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.01 to 1 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/8, Output Specification: Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V, Lead Wire: w/o Lead Wire w/Connector, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.01 to 1 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/8, Output Specification: Out 1: NPN; Out 2: NPN, Lead Wire: -, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
When the valve is open, an orange marker appears in the center of the name plate.
OUT2 P2(n2) P1(n1) Supply pressure verification Leak test CH P2(n1) > P1(n2) 10.0 to 101.0 kPa Increases the set value 1 2 3 4 PRESSURE For normally closed P2(n2) P1(n1) P2(n1) > P1(n2) 0.1 to 1000.0 MPa Decreases the set value SET P3(n3) and P4(n4) are the same as P1(n1) and P2(n2).
An EXH block base assembly is used in the blocking position when ordering an EXH spacer incorporated with a manifold. However, do not order an EXH block base assembly because it is attached to the spacer. When separately ordering an individual EXH spacer, separately order an EXH block base assembly because it is not attached to the spacer.
(An assembly is shipped under the condition shown in the figure.) Note) The EXH port may be either on the lead wire side or on the end plate side. (An assembly is shipped under the condition shown in the figure.)
(An assembly is shipped under the condition shown in the figure.)
but cannot be mounted in this way on (N)AW units when the handle of an (N)AR Series Regulator faces upwards.
) 22.8 10.5 7.4 58.5 39.7 41.8 9.2 22 28.5 22.9 20.4 10.5 8 8 3 x C2, C4, N1, N3 <1(P), 5(EA), 3(EB) port> C2: 2 One-touch fitting C4: 4 One-touch fitting N1: 1/8" One-touch fitting N3: 5/32" One-touch fitting 8.7 With plug connector/light, built-in silencer S0716S-mM(O)-m 16.7 2-Position Double/4-Position Dual 3-Port Grommet: S07 6-mG-m 2 A B C 8 2 x 3.2 5.3 2 x C2, C4, N1, N3 <4(A), 2
With an ejector When a few air cylinders are locally used.
Supply pressure verification Leak test P2(n1) > P1(n2) P2(n2) P1(n1) 10.0 to 101.0kPa CH Increases the set value 1 2 3 4 PRESSURE For normally closed P2(n1) > P1(n2) P2(n2) P1(n1) 0.1 to 1000.0MPa Decreases the set value SET P3(n3) and P4(n4) are the same as P1(n1) and P2(n2).
The valve coil is kept in a deenergized state even when there is an electric signal from the connector. Normal operating condition. Switching of valve is based on an electric signal from the connector.
Do not use an air cylinder as an airhydro cylinder. If it uses turbine oil in place of fluids for cylinder, it may result in oil leakage. 5. Combine the rod end section, so that a rod boot might not be twisted. If a rod boot is installed with being twisted when installing a cylinder, it will cause a rod boot to fail during operation.
Solenoid valve Enter an "X" in the sections for valves to be used. In case of mixed port sizes, indicate by entering C4, L6, etc. In case of a manifold with external pilot specifications, enter an "X" in valve locations where an external pilot is required. Mixed internal and external specifications are also possible in this section.