47.0 2.35 01 59.7 Hastelloy is a registered trademark of Haynes International.
Model Section Type Round type Standard G27-10-R1 G36-10-01 G46-10-01 0.02 to 0.2 MPa setting G27-10-R1 G36-4-01 G46-4-01 Round type (with color zone) Standard G36-10-01-L G46-10-01-L 0.02 to 0.2 MPa setting G36-4-01-L G46-4-01-L Square embedded type Note 2) Standard GC3-10AS [GC3P-010AS (Pressure gauge cover only)] 0.02 to 0.2 MPa setting GC3-4AS [GC3P-010AS (Pressure gauge cover only
TB Td TE TF TH TN Rod End Nut CG-020-24A CG-025-24A CG-032-24A CG-040-24A CG-050-24A CG-063-24A CG-080-24A CG-100-24A 3.2 3.2 4.5 4.5 6 8 11 12 (29.3) (33.1) (40.4) (49.2) (60.4) (74.6) 28 01 13 15 17 21 24 26 36 50 36 43 50 58 70 82 73 90 8 10 12 14 16 18 18 22 10 10 10 10 20 20 5.5 5.5 6.6 6.6 9 11 11 13.5 25 30 35 40 50 60 55 65 RZQ 03 32 01 03 Applicable bore (mm) 20 25 32 40 50 63
A A1 MM U1 L1 RR1 A1 L1 E1 MM RR1 U1 0.4 0.2 + 0.2 + 0 0.2 0.4 0.2 0.4 10 12 16 20 +0.002 0 5 6.4 8 10 0.2 0.4 0.1 0.3 0.2 0.4 0.2 0.4 +0.002 0 5 6.5 8 10 #8-32UNC 10 12 16 20 12 16 20 25 10 12 16 20 14.6 16.6 21 25.6 RCS-01 RCS-015 RCS-02 RCS-025 RCD-01 RCD-015 RCD-02 RCD-025 21.5 32 34 41 6 6 6 8 16 25 25 30 #8-32UNC #8-32UNC #10-32UNF 1/4-28UNF 6.3 12 10.3 18 7 14 11.5 14
/02--X693 PFM7S-01/02--X693 A B C() A B C() Rc1/81/4 Rc1/81/4 NPT1/81/4 NPT1/81/4 13 11 17 13 11 17 G1/8 G1/8 G1/4 17 15 21 G1/4 17 15 21 -73No.PF-OMJ0005CN-I PFM7-C4/C6/C8/N7--X694 PFM7S-C4/C6/C8/N7--X694 A B A B C4 4(5/32) 10.1 36.1 C4 4(5/32) 10.1 8.1 C6 6 10.3 36.3 C6 6 10.3 8.3 C8 8(5/16) 12 37 C8 8(5/16) 12 10 N7 1/4 10.3 36.3 N7 1/4 10.3 8.3 PFM7-01/02--X694 PFM7S-01/02--X694
CX D-G5NBL 35 40 45 45 45 40 50 45 D-G5/K5 D-B7/B8 BM1 -01 BM1 -02 BM1 -32 BM1 -04 BM1 -05 BM1 -06 Since this is a guideline including hysteresis, not meant to be guaranteed.
PFM7-C4/C6/C8/N7--X693 PFM7S-C4/C6/C8/N7--X693 PFM7-01/02--X693 PFM7S-01/02--X693 -73No.PF-OMJ0006-J PFM7-C4/C6/C8/N7--X694 PFM7S-C4/C6/C8/N7--X694 PFM7-01/02--X694 PFM7S-01/02--X694 -74No.PF-OMJ0006-J For a mixture of Argon (Ar) and carbon dioxide (CO2) The mixture ratio can be selected from Ar : CO2 = 92 : 8, 90 : 10, 80 : 20, 70 : 30 or 60 : 40.
How to Order X214 01 S AS 2 2 0 0 Body size Option Port size Model Thread type Control method Speed Controller with One-touch Fitting Elbow Type, Metal Body/Series AS Refer to How to Order in page 15-9-43 for standard specifications. How to Order X214 2 2 1 01 06 S AS 1FG Body size Option Applicable tubing O.D.
: 2.5 L/min, PF2M710: 5 L/min PF2M725: 12.5 L/min, PF2M750: 25 L/min PF2M711: 50 L/min, PF2M721: 100 L/min [ ] 5% of maximums rated flow PF2M701: 0.05 L/min, PF2M702: 0.1 L/min PF2M705: 0.25 L/min, PF2M710: 0.5 L/min PF2M725: 1.3 L/min, PF2M750: 2.5 L/min PF2M711: 5 L/min, PF2M721: 10 L/min Socket Thank you for purchasing an SMC PF2M7## Digital Flow Switch.
G33-4-01 G33-10-01 G43-2-01 G43-4-01 G43-10-01 G43-10-01 G43-4-01 G43-10-01 Accuracy + 3% (full span) Courtesy of Steven Engineering, Inc. !
pilot port (Only external pilot style(R)) 3 4 5 3 4 5 L plug connector (L): VQZ2 5 (R)lLl 0 1 01 02 0 1 01 02 DIN connector (Y): VQZ2 5 (R)lYl Indicator light 148<150> 300 (Lead wire length) 67.5<68.5> Applicable cord O.D. 3.5 to 7 Pg.7 155.5 MAX.10 53<56.5> 71.5 Indicator light Cover diameter 1.5 Cross section 0.23mm2 < >: AC 82.5 75 3 4 5 M plug connector (M): VQZ2 5 (R)lMl 0 1 01 02
Specifications [Surface finish Ra] Surface finish of the inner surface (wetted parts). A standard for measuring surface roughness which averages the peak to valley of the surface profile over a given distance (stroke). Multiple readings on a part are also averaged for Ra, but for Ra max, the worst reading is the value for that part.
+.002 1.88 2.56 3.50 .75 NCA1-P325 1.25 0 0.75 +.004 .53 .78 .62 -.01 +.002 Courtesy of Steven Engineering, Inc. !
With air cushion 2 x M5 x 0.8 Relief port RA GA WA RA GA WA Cushion valve (Width across flats WH) Cushion valve (Width across flats WH) 10 10 20 20 ZZ + 2 Stroke S + Stroke (mm) A AL Bore size Stroke range Standard Long B1 C D E F GA H H1 I J K KA MM NA P RA S 1 2 ZZ 20 20 20 13 14 14 20 20 2 2 2 2 2 2 3 3 12 14 18 25 30 32 40 50 8 10 12 16 20 20 25 30 14 16.5 20 26 32 38 50 60 13 17 17 19
V Panel mount adapter (For with flow adjustment valve) PFM ZS-33-JS PFMV Panel mount adapter A PF2A Panel mount adapter B Made to Order PF2W Specification/Description Symbol X693 X694 PF2D Change of piping entry direction combination Panel IF Compatible with argon (Ar) and carbon dioxide (CO2) mixed gas X731 Mounting bracket For details, refer to page 940 through to 942.
Specifications [Surface finish Ra] Surface finish of the inner surface (wetted parts). A standard for measuring surface roughness which averages the peak to valley of the surface profile over a given distance (stroke). Multiple readings on a part are also averaged for Ra, but for Ra max, the worst reading is the value for that part.
Main shaft Double action actuator OUT2 Main shaft Single action actuator X OUT1 OUT2 OUT1 X SUP The cam of the positioner should be set on the RA surface. SUP SUP The cam of the positioner should be set on the RA surface. The cam of the positioner should be set on the RA surface. IN + IN + IN + OUT1 is plugged.
Main shaft Double action actuator OUT2 Main shaft Single action actuator OUT1 OUT2 OUT1 SUP The cam of the positioner should be set on the RA surface. SUP SUP The cam of the positioner should be set on the RA surface. The cam of the positioner should be set on the RA surface. IN + IN + IN + OUT1 is plugged.
0.5 to 10 psig (0.0034 to 0.07 MPa) 1 to 30 psig (0.007 to 0.2 MPa) 5 to 100 psig (0.034 to 0.7 MPa) 15 to 200 psig (0.1 to 1.4 MPa) 15 to 300 psig (0.1 to 2.1 MPa) Code No code P 01 02 10 20 30 Connections (Inletq, Outletw) 3) Panel mounting hole: dia. 1.42 inch (36.1 mm).