Do not use in an atmosphere containing an inflammable gas or explosive gas. Use in such an atmosphere is likely to cause a fire or explosion. This system is not explosion-proof. Caution 1. Select the proper type of enclosure according to the environment of operation.
An auto switch magnet is not installed. In cases where an auto switch magnet is installed, add -M9// to the part number. (Not available for the high-temperature type) An auto switch is not attached. When a product with an auto switch is required, add the symbol for the auto switch to the part number.
In addition, by connecting an input block a maximum of 32 sensor signal inputs are possible. Input block This is an expansion block which connects to an SI unit to perform sensor input from auto switches, etc.
When the valve is open, an orange marker appears in the center of the name plate.
OUT2 P2(n2) P1(n1) Supply pressure verification Leak test CH P2(n1) > P1(n2) 10.0 to 101.0 kPa Increases the set value 1 2 3 4 PRESSURE For normally closed P2(n2) P1(n1) P2(n1) > P1(n2) 0.1 to 1000.0 MPa Decreases the set value SET P3(n3) and P4(n4) are the same as P1(n1) and P2(n2).
An EXH block base assembly is used in the blocking position when ordering an EXH spacer incorporated with a manifold. However, do not order an EXH block base assembly because it is attached to the spacer. When separately ordering an individual EXH spacer, separately order an EXH block base assembly because it is not attached to the spacer.
(An assembly is shipped under the condition shown in the figure.)
(An assembly is shipped under the condition shown in the figure.) Note) The EXH port may be either on the lead wire side or on the end plate side. (An assembly is shipped under the condition shown in the figure.)
but cannot be mounted in this way on (N)AW units when the handle of an (N)AR Series Regulator faces upwards.
) 22.8 10.5 7.4 58.5 39.7 41.8 9.2 22 28.5 22.9 20.4 10.5 8 8 3 x C2, C4, N1, N3 <1(P), 5(EA), 3(EB) port> C2: 2 One-touch fitting C4: 4 One-touch fitting N1: 1/8" One-touch fitting N3: 5/32" One-touch fitting 8.7 With plug connector/light, built-in silencer S0716S-mM(O)-m 16.7 2-Position Double/4-Position Dual 3-Port Grommet: S07 6-mG-m 2 A B C 8 2 x 3.2 5.3 2 x C2, C4, N1, N3 <4(A), 2
With an ejector When a few air cylinders are locally used.
Supply pressure verification Leak test P2(n1) > P1(n2) P2(n2) P1(n1) 10.0 to 101.0kPa CH Increases the set value 1 2 3 4 PRESSURE For normally closed P2(n1) > P1(n2) P2(n2) P1(n1) 0.1 to 1000.0MPa Decreases the set value SET P3(n3) and P4(n4) are the same as P1(n1) and P2(n2).
The valve coil is kept in a deenergized state even when there is an electric signal from the connector. Normal operating condition. Switching of valve is based on an electric signal from the connector.
Do not use an air cylinder as an airhydro cylinder. If it uses turbine oil in place of fluids for cylinder, it may result in oil leakage. 5. Combine the rod end section, so that a rod boot might not be twisted. If a rod boot is installed with being twisted when installing a cylinder, it will cause a rod boot to fail during operation.
Solenoid valve Enter an "X" in the sections for valves to be used. In case of mixed port sizes, indicate by entering C4, L6, etc. In case of a manifold with external pilot specifications, enter an "X" in valve locations where an external pilot is required. Mixed internal and external specifications are also possible in this section.
1 N1 1 N1 2 N2 2 N2 2 N2 2 N2 MHY MHZ2-16 MHZ2-16 MHZ2-20 MHZ2-20 MHW MHZ2-25 MHZ2-25 1 N1 MHZ2-32 1 MHZ2-32 2 MRHQ MHZ2-40 1 MHZ2-40 2 Specifications and dimensions other than the above are the same as the basic type (including narrow type).
Also, when wiring is not required for a station that is to be mounted with an option such as an individual SUP spacer, enter an "X".
Note 8 10 12 16 20 25 Every set includes: n1 rod packing n1 packing retaining washer n1 retaining ring 20 C85-20PS Foot (1 pc.) C85L16A C85L25A C85L10A Foot (2 pcs. with mounting nut 1 pc.)
N o t e 3 ) F.P. and S. kits are provided with an exhaust on one side, while C kits are with an exhaust on both sides. K I TE L E C T R I C A L E N T R YC A B L E L E N G T H Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 !
An F.R.L. unit has its own minimum operating pressure depending on the equipment and is designed specifically to function with compressed air. If used below the minimum operating pressure, a loss of performance and malfunction can occur. Please contact SMC if an application under such conditions cannot be avoided.