200 400 600 800 1000 1200 0 100 200 300 400 500 600 0 200 400 600 800 1000 1200 V (mm/s) V (mm/s) V(mm/s) LEFS16 LEFS25 LEFS32 50 12 B B 20 B A 10 A 40 H H A W(kg) W(kg) W(kg) 15 8 30 6 10 20 4 5 10 2 0 0 0 0 100 200 300 400 500 600 0 100 200 300 400 500 600 0 100 200 300 400 500 600 V(mm/s) V (mm/s) V(mm/s) 10 - Step motor (servo 24VDC) Ball screw drive LEFS40 Model 150 to 1200 Stroke [
1 1 C G LJ1 10 S W X10 Guide type Slider guide S X10 Non-standard motor Series Series 10 Series 20 Series 30 Limit switch 10 20 30 Nil W None B contact specification 2 pcs.
TEST DATA MONITOR No.0 1 No. 0 50.00mm 250mm/s ALARM JOG SETTING DATA SET 40 SET 1 No. 0 40.00mm 100mm/s 250100mm/s 1 No. 0 40.00mm 250mm/s MENU 100 SET TEST DATA MONITOR No.0 1 No. 0 40.00mm 250mm/s No.1 1 No. 0 40.00mm 250mm/s ALARM JOG SETTING No.
pulse input CW pulse input CCW pulse input CCW pulse input Frame ground 60 OZ CZ CW+ Command divider switching input CW drive suppression input CCW drive suppression input Servo alarm output CW CCW+ CCW Positioning complete signal output Speed monitor signal FG With open collector Example for driver connection between equipment + R Vp Vp 1.5 R + 220 CN I/F is approx. 10mA GND 1 4 AM26LS31
Description Material 1 Rod Cover Aluminum alloy NCA200-02AQ3609-S NCA200-03-Q3609-S NCA250-02AQ3610-S NCA250-03-Q3610-S NCA325-02AQ3611-S NCA325-03-Q6311-S 2 Head Cover Aluminum alloy 3 Cylinder Tube Aluminum alloy Please See below for How to order Cylinder Tube 4 Piston Rod Carbon steel Available only as an Assembled Item.
100 300 Speed (mm/s) Speed (mm/s) Speed (mm/s) 300 300 CEP1 Max. 500 mm/s of high speed transfer is possible.
1 1/4B to 2B CW-5H-W Phosphoric ester CW-5H-V PAT.
Example using a 20[mm] Lead Actuator with target travel speed of 500[mm/sec] Rotations per second Travel distance per second Travel distance per rotation Rotation Speed (rpm) = {Speed (mm/s) Lead (mm) }60 (S) = {500 (mm/s) 20 (mm) }60 (s) =1500 (rpm) The rotation speed must be a value between 0 and the allowable actuator speed. The actuator will not operate if set to 0.
Example using a 20[mm] Lead Actuator with target travel speed of 500[mm/sec] Rotations per second Travel distance per second Travel distance per rotation Rotation Speed (rpm) = {Speed (mm/s) Lead (mm) }60 (S) = {500 (mm/s) 20 (mm) }60 (s) =1500 (rpm) The rotation speed must be a value between 0 and the allowable actuator speed. The actuator will not operate if set to 0.
pulse input CW pulse input CCW pulse input CCW pulse input Frame ground 60 OZ CZ CW+ Command divider switching input CW drive suppression input CCW drive suppression input Servo alarm output CW CCW+ CCW Positioning complete signal output Speed monitor signal FG With open collector Example for driver connection between equipment + R Vp Vp 1.5 R + 220 CN I/F is approx. 10mA GND 1 4 AM26LS31
80 mm/s2 Target position 2: Travel distance 5 mm, Travel speed 20 mm/s, Acceleration 80 mm/s2, Deceleration 80 mm/s2 ii.Calculation example Travel distance [Number of pulses (pulse)] = Travel distance (mm) Encoder resolution (m/pulse) Travel speed [Pulse frequency (pulse/s)] = Travel speed (mm/s) Encoder resolution (m/pulse) Acceleration and Deceleration time [s] =Travel speed (mm/s) /
After 1.6 s Blinking After 0.2 s When an alarm or warning also occurs during the test operation, the decimal point on the first digit will blink as follows. After 0.8 s After 0.8 s Blinking Blinking After 0.2 s (4) Start operation with the PC. -21- 5.2 JOG Mode JOG operation can be executed without host command.
Rotations per Second Distance of movement per second Distance of movement per rotation Rotation Speed (rpm) = Speed (mm/s) Lead (mm) }60 (S) = {500 (mm/s) 20 (mm) }60 (s) =1500 (rpm) -36- 6.6.3 Acceleration/deceleration Time Configuration < Acceleration/deceleration Time Configuration> Acceleration/deceleration time (ms) configuration: The acceleration/deceleration time sets the amount
(CCW: Counterclockwise, C: Center, CW: Clockwise) C C C C CW CCW CW CCW CW CCW CW CCW Left 90: Right 90 Left 45: Right 45 Left 90: Right 30 Left 60: Right 90 Working Principle This model uses a 3-position 5-port solenoid valve (pressure center).
Rotations per Second Distance of movement per second Distance of movement per rotation Rotation Speed (rpm) = Speed (mm/s) Lead (mm) }60 (S) = {500 (mm/s) 20 (mm) }60 (s) =1500 (rpm) -38- 6.6.3 Acceleration/deceleration Time Configuration < Acceleration/deceleration Time Configuration> Acceleration/deceleration time (ms) configuration: The acceleration/deceleration time sets the amount
F (LC6D-2 only) +24V GND CW+ CW CCW+ CCW PD+ PD A B C D E 7 6 3 10 CW CW 10 10 2 R 330 CCW input 330 CCW input 2 2 9 1 CCW CCW 8 9 9 5 4 14 13 12 R 330 PD input 1 PD 8 11 F Functions Function change-over switch Input signal terminal CW pulse input terminal By applying the pulse input, the actuator moves from the motor side to the end side.
Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: 01 (Rc1/8), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: S (Bracket, w/Flow Adjustment Valve)
Rated Flow Range: 0.5 to 50 L/min, Flow Adjustment Valve: With Flow Adjustment Valve, Straight, Port Size: Rc1/8, Output Specification: Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V, Lead Wire: Lead Wire w/Connector + Rubber Cover for Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Bracket, w/Flow Adjustment Valve, Calibration Certificate: -, Made
+ CWCCW+ CCWFG A 35 45 Z phase output Z phase output Z phase output CW pulse input CW pulse input CCW pulse input CCW pulse input Frame ground Command divider switching input CW drive suppression input CCW drive suppression input Servo alarm output Positioning completion signal output Speed monitor signal Equipment connection example With open collector Vp-1.5 : Approx. 10mA + CN I/F R Vp