Rated Flow Range: 60 to 6000 l/min, Thread Type: NPT, Port Size: 1 1/2, Output Specification: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: Lead Wire and M12-M12 Connector, 3m, Unit Specification: SI Unit Only, Calibration Certificate: -
Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: N (NPT), Port Size: 14 (1 1/2), Output Specification: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only)
Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: N (NPT), Port Size: 14 (1 1/2), Output Specification: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: Q (Lead Wire and M12-M12 Connector, 3m), Unit Specification: M (SI Unit Only)
Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: N (NPT), Port Size: 14 (1 1/2), Output Specification: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series], Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: M (SI Unit Only)
DIGITAL FLOW SWITCH, SENSOR, DIGITAL AIR FLOW, O24, 1315.00000 lb
DIGITAL FLOW SWITCH, SENSOR, DIGITAL AIR FLOW, O24, 999 lb
DIGITAL FLOW SWITCH, SENSOR, DIGITAL AIR FLOW, O24, 999 lb
DIGITAL FLOW SWITCH, SENSOR, DIGITAL AIR FLOW, O24, 999 lb
DIGITAL FLOW SWITCH, SENSOR, DIGITAL AIR FLOW, O24, 1220.00000 lb
DIGITAL FLOW SWITCH, SENSOR, DIGITAL AIR FLOW, O24, 1220 lb
Digital Flow Switch, SENSOR, DIGITAL AIR FLOW, O24, 1.19000 lb
DIGITAL FLOW SWITCH, SENSOR, DIGITAL AIR FLOW, O24, 999 lb
DIGITAL FLOW SWITCH, SENSOR, DIGITAL AIR FLOW, O24, 1220.00000 lb
DIGITAL FLOW SWITCH, SENSOR, DIGITAL AIR FLOW, O24, 1250.00000 lb
SENSOR, DIGITAL AIR FLOW. DIGITAL FLOW SWITCH. 1.28000 lb. O24.
SENSOR, DIGITAL AIR FLOW. Digital Flow Switch for Large Flow. 1.29000 lb. O24.
3000 L/min 6000 L/min 12000 L/min 30 L/min 3000 L/min PF3A703H 3150 L/min 30 L/min 0 L/min 3150 L/min 60 L/min 6000 L/min PF3A706H 6300 L/min 60 L/min 6300 L/min 0 L/min 120 L/min 12000 L/min 12600 L/min 12600 L/min PF3A712H 120 L/min 0 L/min Rated flow range Set point range Display range Analog Output Output Output Flow/Analog Output 0 L/min A*2 B Voltage output (1 to 5 V)*1 1 V 1.04 V
Item PF3A703H PF3A706H PF3A712H Current flow rate [P_1] Set value of OUT 1500 L/min 3000 L/min 6000 L/min button (UP) Safety Instructions Main display [H_1] Hysteresis of OUT 150 L/min 300 L/min 600 L/min S button (SET) Maintenance Connecting/Disconnecting Align the lead wire connector with the connector key groove, and insert it straight in. Turn the knurled part clockwise.
(For accumulated decrement) [ 150] 150 L/min (PF3A703H) [ H] Setting of Hysteresis [ 300] 300 L/min (PF3A706H) Caution Press the button once to reduce the value by one digit, press and hold to continuously reduce. [ 600] 600 L/min (PF3A712H) : If the error cannot be reset after the above measures are taken, then please contact SMC.
H E R M A N I F O L D O P T I O N S : L A T C H I N G S O L E N O I D T Y P E L A T C H I N G T Y P E V A L V E L A T C H I N G T Y P E V A L V E W I T H M A N U A L O V E R R I D E M A N I F O L D O P T I O N P A R T S A V A I L A B L E : P E R F E C T C H E C K B L O C K P E R F E C T C H E C K B L O C K W I T H V A L V E O R M A N I F O L D Courtesy of Steven Engineering, Inc. !