Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/8, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: Calibration Certificate, Made to
Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/8, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/8, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °F, Bracket: Bracket, Calibration Certificate: -, Made to Order: -
100 g 1OFF (2 5 ) 5 100 (24 5 min100 500 min9.5 ) 290(7 s) 390(7 s) -67No.PF-OMN0011CN-C 0100 1 / -10110 1 3F.S. 7 s 2 5F.S. 1090 2 (ZS-40-W) AWG26 0.51 mm 1.00 mm 3.5 mm -68No.PF-OMN0011CN-C / (PF3W704/720740) A B C 1 V 1.5 V 5 V 4 mA 6 mA 20 mA (PF3W711) A B C 1 V 1.4 V 5 V 4 mA 5.6 mA 20 mA (PF3W721) A B C 1 V 1.5 V 5 V 4 mA 5.9 mA 20 mA [L/min] PF3W504 0.5 4 PF3W520 2 16
(Excludes power supply and output cable) Weight Power supply/Output cable 60 g e-CON (1 pc.) 2 g IO-Link type Device IO-Link version V1.1 Communication speed COM2 (38.4 kbps) Configuration file IODD file9 Communication (IO-Link mode) Minimum cycle time 4.8 ms Process data length Input data: 10 bytes, Output data: 0 bytes On request data communication Yes Data storage function Yes Event function
Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water. The PF3W series has been improved both in design and operating performance over the PF2W flow switch. Depending on the selected model, the PF3W is up to 40% smaller in volume, offering improved piping space and flexibility. Designed to work with fluids up to 90ºC
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 04 (1/2), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: None, Calibration Certificate: None
Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: G, Port Size: 1/2, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: EPDM Seal
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C)
Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/8, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: -, Calibration Certificate: -, Made to Order: -
) 3/8" (9.53) KFG2F1395-N03 42 8.5 15.6 31.6 19 8.5 3/8 51 19 Union Nut: KFG2N Weight (g) H (Width across flat) Applicable tube O.D.
www.stevenengineering.com A C T U AT O R S P R O D U C T S E L E C T O R PA G E 1.1 VA LV E S P R O D U C T S E L E C T O R PA G E 2.1 F L O W C O N T R O L E Q U I P M E N T P R O D U C T S E L E C T O R PA G E 3.1 F I T T I N G S A N D T U B I N G P R O D U C T S E L E C T O R PA G E 4.1 A I R P R E PA R AT I O N P R O D U C T S E L E C T O R PA G E 5.1 VA C U U M P R O D U C T S E L E
-N03 17.46 22.23 22.23 108.2 63.3 34.3 37.1 NPT1/4 NPT3/8 NPT3/8 ZH18DA-N03-N03-N03 22.23 131 73.6 41.1 39 NPT3/8 ZH20DA-N03-N04-N04 23.81 23.81 142.6 74.9 44.1 NPT1/2 NPT1/2 Inch Dimensions when the standard bracket is mounted 229 A ZH Series Body Ported: ZH05D A--to ZH20D A--S L S L L-bracket (Bracket on a single side) K J H E F G 2 x D t C B A Long clamping screw set for 1 station required
Body size 1 2 3 4 M5 standard 1/8, 1/4 standard 3/8 standard 1/2 standard Port size Type Symbol Cylinder side In the side of solenoid valve M5 01 02 03 04 F01 F02 F03 F04 U10/32 N01 N02 N03 N04 Elbow 2 M5 x 0.8 R 1/8 R 1/4 R 3/8 R 1/2 R 1/8 R 1/4 R 3/8 R 1/2 10-32 UNF NPT 1/8 NPT 1/4 NPT 3/8 NPT 1/2 M5 x 0.8 Rc 1/8 Rc 1/4 Rc 3/8 Rc 1/2 G 1/8 G 1/4 G 3/8 G 1/2 10-32 UNF NPT 1/8 NPT 1/4 NPT
/8 NPT 1/4 AS320-F02-SD G 3/8 AS320-02-SD Rc 3/8 19 22.5 R 1/4 24.3 9.8 30 54.8 21.9 1.2 49.3 123 AS320-N03-SD NPT 3/8 NPT 3/8 AS320-F03-SD G 3/8 AS320-03-SD Rc 3/8 19 22.5 R 3/8 24.3 9.8 30 52.6 19.7 1.2 47.4 128 AS420-N04-SD NPT 1/2 23.8 NPT 1/2 AS420-F04-SD G 1/2 AS420-04-SD Rc 1/2 24 27.5 R 1/2 28.5 12.4 38.5 62.9 25.8 1.2 55.8 222 Reference thread dimensions after installation. 751
19 19 1/2" (12.7) 3/8" (9.53) KQG2 KFG2F1395-N03 42 19 3/8 31.6 15.6 8.5 8.5 51 19 KG KFG2 KFG2 Union Nut: KFG2N MS Weight (g) H (Width across flat) Applicable tubing O.D.
AS331F-N03 NPT 3/8 AS421F-N04 AS431F-N04 NPT 1/2 Note 1) Elbow type only Note 2) Meter-out and meter-in types can be visually differentiated by the flow direction symbol on the resin body.
See Pressure Gauges Page P R E S S U R E G A U G E S Courtesy of Steven Engineering, Inc. !