SMC Corporation of America
Elite Part Number Search
Search Results "PFCA710-N1-1-M"

side piping: 6 x 4 Detection nozzle: 1.5 Supply pressure: 100 kPa Set distance: 0.15 mm Detection side piping: 6 x 4 Detection nozzle: 2.0 Supply pressure: 100 kPa Set distance: 0.3 mm IF Data 3 1.5 Piping tubing length Piping tubing length 10 m 2.5 10 m 1.2 Response time (sec) Response time (sec) 8 m 2 0.9 5 m 8 m 1.5 0.6 5 m 1 3 m 3 m 0.3 0.5 1 m 0 0.02 0.04 0.06 0.08 0.1 0.12 0.14 0.16

3.0 m cable Flat ribbon cable (26P) with 5.0 m cable 25 pins IP40 compliant IP67 compliant 1 to 12 stations (24) FD0 FD1 FD2 FD3 D-sub connector (25P) without cable D-sub connector (25P) with 1.5 m cable D-sub connector (25P) with 3.0 m cable D-sub connector (25P) with 5.0 m cable 1 to 12 stations (24) 1 to 9 stations (18) 1 to 10 stations (20) Terminal block box PDC TD0 Flat ribbon cable

Speed controller Silencer Tube x Length Speed controller Silencer SX3140-01 SX3120-C6 AS3001F-06 AN110-01 AS2051F-06 AN120-M5 T0604 x 1 m T0806 x 1 m AS3001F-08 T0604 x 1 m T0806 x 1 m AS3001F-08 SX5140-02 SX5120-01 AS3001F-06 AS3001F-06 AN101-01 AN101-01 AS4001F-10 T0604 x 1 m T1075 x 1 m T1209 x 1 m AS3001F-06 T0604 x 1 m AS3001F-06 T1075 x 1 m AS4001F-10 SX7140-03 SX7120-02 SV AS200-02

Rated Control Flow Range: 10 (0.1 to 10 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: Unit Specification, Bracket: None, Operation Manual/Calibration Certificate: K (with Operation Manual and Calibration Certificate

Rated Control Flow Range: 10 (0.1 to 10 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: Unit Specification, Bracket: R (Bracket (mounting position: Side), Operation Manual/Calibration Certificate: K (with Operation

Rated Control Flow Range: 10 (0.1 to 10 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: N (Without Lead Wire w/Function), Unit Specification: M (SI units only), Bracket: S (Bracket (mounting position: Stream side)), Operation Manual/Calibration Certificate: K (with Operation

Rated Control Flow Range: 10 (0.1 to 10 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: Unit Specification, Bracket: S (Bracket (mounting position: Stream side))

Rated Control Flow Range: 10 (0.1 to 10 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: Unit Specification, Bracket: R (Bracket (mounting position: Side), Operation Manual/Calibration Certificate: Y (None)

Rated Control Flow Range: 10 (0.1 to 10 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 1 (Input: Analog 1 to 5 V, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 1 to 5V or 0 to 10V), Wire Connector: Q (M12-M12 lead wire with connector (3 m/5 core)), Unit Specification: Unit Specification, Bracket: R (Bracket (mounting position: Side)

Rated Control Flow Range: 10 (0.1 to 10 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 1 (Input: Analog 1 to 5 V, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 1 to 5V or 0 to 10V), Wire Connector: N (Without Lead Wire w/Function), Unit Specification: Unit Specification, Bracket: R (Bracket (mounting position: Side)

Rated Control Flow Range: 10 (0.1 to 10 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: Unit Specification, Bracket: R (Bracket (mounting position: Side)

Rated Control Flow Range: 10 (0.1 to 10 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: Unit Specification, Bracket: S (Bracket (mounting position: Stream side)), Operation Manual/Calibration Certificate: K (

Rated Control Flow Range: 10 (0.1 to 10 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: Unit Specification, Bracket: None, Operation Manual/Calibration Certificate: Y (None)

Rated Control Flow Range: 10 (0.1 to 10 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: N (Without Lead Wire w/Function), Unit Specification: Unit Specification, Bracket: S (Bracket (mounting position: Stream side)), Operation Manual/Calibration Certificate: T (Calibration

Rated Control Flow Range: 10 (0.1 to 10 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: Unit Specification, Bracket: None, Operation Manual/Calibration Certificate: T (Calibration Certificate Only)

type(R)) 34.5 53 5.5 (Lead wire length) 39.5 7.8 (N1, N3, N7) 300 (M5) Cover diameter 1.4 Cross sectional area 0.2mm2 42.5 (11) R P 15 1 3 8 1/8 NPTF R(EXH) port 16.3 13.4 2-M5 x 0.8 PE port 41.2 46.5 1/8 NPTF P(SUP) port L type plug connector (L) M type plug connector (M) 55.5 300 (Lead wire length) 66 300 (Lead wire length) Cover diameter 1.5 Cross sectional area 0.23mm2 Indicator light

m m 0 . 0 1 m m 0 . 0 1 m m 0 . 0 1 m m 0 . 0 1 m m 0 . 0 1 m m Fluid A i r A i r A i r A i r A i r A i r Operating Pressure 0.2~0.6MPa 0.15~0.6MPa 0.2~0.6MPa 0.15~0.6MPa (29~87PSI) 22~87PSI 29~87PSI 22~87PSI Ambient and Fluid Temperature 0 ~ 6 0 C ( 3 2 ~ 1 4 0 F ) 0 ~ 6 0 C ( 3 2 ~ 1 4 0 F ) Max Operating Frequency 1 8 0 c . p . m 1 8 0 c . p . m Lubrication N o n l u b e N o n l u

x 1 m T1209 x 1 m SY7120-02 SY7140-03 AS4001F-10 AS3001F-06 AS3001F-06 AN110-01 AN200-02 T0604 x 1 m T1075 x 1 m T1209 x 1 m T1209 x 1 m AS3001F-06 AS4001F-10 AS4001F-12 T0604 x 1 m T1075 x 1 m SY9120-03 SY9140-04 AS3001F-06 AS4001F-10 AS4001F-12 AN200-02 AN200-02 AN202-02 Conditions [When using SGP (steel pipe)] Conditions [When using SGP (steel pipe)] Body ported Base mounted Series CS1

4 (A), 2 (B) port C4, C6, M5 Weight W (g) (2) n1: Stations n2: Number of SUP/EXH blocks m: Weight of DIN rail W = 3.2n1 + 53n2 + m + 126.5 Note 1) In cases such as those where many valves are operated simultaneously, use type B (double side SUP/EXH), applying pressure to the 1(P) ports on both sides and exhausting from the 3(R) ports on both sides.

Axial foot style (2) Rod side flange style (1) Head side flange style (1) CJ1 Clevis integrated style (1) (1) Single clevis style CJP (1) (3) Double clevis style Rod side trunnion style (1) (2) CJ2 (2) Head side trunnion style (1) CM2 Boss-cut basic style (1) Boss-cut flange style (1) CG1 Boss-cut trunnion style (1) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San