SMC Corporation of America
Elite Part Number Search
Search Results "PFM511-C6-2-NA"

S U D side D U side 2 to 10 stations B Special specifications M 2 to 20 stations Both sides Made to order. When using both types, specify C4 and C6 specifically; do not just use X marking.

Refer to pages 13-2-4 to 13-2-5 for ejector system unit. Refer to pages 13-2-32 for ejector system manifold. Refer to pages 13-2-40 to 13-2-41 for external vacuum supply system unit. Single unit Single unit 13-2-68 to 13-2-72 Manifold Manifold Refer to page 13-2-54 for external vacuum supply system manifold.

Ejector valve ZYY35LZ-10S-E15C Double solenoid (24 VDC) SY3240-5LZ J ZZY 1 U Single solenoid (24 VDC) SY3140-5LZ Blanking plate assembly SX3000-75-1A Cylinder port size C6 : With 6 One-touch fitting Manifold base (4 stations) ZZYY3-45-04D-C6-J1U With ejector Number of ejectors 1 to 10 Example) ZYY-J3U ZYY35LZ-10S1-E15C ZYY35LZ-10S 2 SET 1 SET 1 SET U side Stations3 2 1 D side 13-8-6 7 Ejector

Actuation: 2 (2 Position Double), Mounting/Porting: 3 (Top Ported), Seal: 0 (Rubber Seal), Pilot Specification: Internal Pilot, Pilot Valve: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Light/Surge Suppressor/Common Specification: U (w/Light/Surge Voltage Suppressor, Non-polar), Manual Override: Non-locking Push Type, A,B Port Size: C6 (ø6 One-touch Fitting), Thread

Actuation: 2 (2 Position Double), Mounting/Porting: 3 (Top Ported), Seal: 0 (Rubber Seal), Pilot Specification: Internal Pilot, Pilot Valve: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Light/Surge Suppressor/Common Specification: U (w/Light/Surge Voltage Suppressor, Non-polar), Manual Override: D (Push-turn Locking Slotted Type), A,B Port Size: C6 (ø6 One-touch Fitting

(ø6 One-touch Fitting), Thread: Rc (or No Selection in the Case of One-touch Fittings), Mounting Option: Mounting Screw, Round Head Combination Screw, Pressure Sensor: P2 (2 Pcs.), NA: NA

: Rc (or No Selection in the Case of One-touch Fittings), Mounting Option: Mounting Screw, Round Head Combination Screw, Pressure Sensor: None, NA: NA

), Thread: Rc (or No Selection in the Case of One-touch Fittings), Mounting Option: Mounting Screw, Round Head Combination Screw, Pressure Sensor: None, NA: NA

Fitting), Thread: Rc (or No Selection in the Case of One-touch Fittings), Mounting Option: Mounting Screw, Round Head Combination Screw, Pressure Sensor: P2 (2 Pcs.), NA: NA

Enclosure: W (IP67), SI Unit: NA (PROFIBUS DP - 32 Outputs - Connector M12), SI Unit Output Polarity: N (-COM), Stations: 2 Stations, P, E Port Entry: B (Both Sides 2~16 Stations), SUP/EXH Block Assembly: Internal Pilot, A, B Port: C6 (ø6 One-touch Fitting)

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: C6 (ø6 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)]

: IP40, Lead Wire: With lead wire with connector (2 m), Handling Instructions: With Instruction Manual (Japanese and English), Calibration Certificate included: Without calibration certificate, Flow rate control valve: None, Custom-made Specifications: None, Rating Flow Range(L/min): 2 to 100 (50), Accessory: None, Option: None, Analog Current Output(mA): 4 to 20

Model: 11S (Bottom Ported), SI Unit Specification: NA (PROFIBUS DP - 32 Outputs - Connector M12), SI Unit Ouput Polarity: N (Negative Common, PNP), Valve Stations: 5 Stations, P,E Port Entry: U (U Side, 2 to 10 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C6 (ø6 One-touch Fitting, Straight, Metric)

Model: 10S (Side Ported), SI Unit Specification: NA (PROFIBUS DP - 32 Outputs - Connector M12), SI Unit Ouput Polarity: N (Negative Common, PNP), Valve Stations: 5 Stations, P,E Port Entry: U (U Side, 2 to 10 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C6 (ø6 One-touch Fitting, Straight, Metric)

Type: 10S (Side Ported), SI Unit Specification: NA (PROFIBUS DP - 32 Outputs - Connector M12), SI Unit Output Polarity: Positive Common, NPN or w/o SI Unit, Valve Stations: 2 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block: R (External Pilot), A, B Port Size: C6 (ø6 One-touch Fitting), Mounting: D (DIN Rail Mounting w/o Name Plate), DIN Rail Option: 13 (for 13 Stations; Longer

Enclosure: W (IP67), SI Unit: NA (PROFIBUS DP - 32 Outputs - Connector M12), SI Unit Output Polarity: N (-COM), Stations: 16 Stations, P, E Port Entry: B (Both Sides 2~16 Stations), SUP/EXH Block Assembly: S (Internal Pilot, Built-in Silencer), A, B Port: C6 (ø6 One-touch Fitting)

Enclosure: W (IP67), SI Unit: NA (PROFIBUS DP - 32 Outputs - Connector M12), SI Unit Output Polarity: N (-COM), Stations: 3 Stations, P, E Port Entry: B (Both Sides 2~16 Stations), SUP/EXH Block Assembly: Internal Pilot, A, B Port: C6 (ø6 One-touch Fitting)

Enclosure: W (IP67), SI Unit: NA (PROFIBUS DP - 32 Outputs - Connector M12), SI Unit Output Polarity: N (-COM), Stations: 8 Stations, P, E Port Entry: B (Both Sides 2~16 Stations), SUP/EXH Block Assembly: Internal Pilot, A, B Port: C6 (ø6 One-touch Fitting)

Enclosure: W (IP67), SI Unit: NA (PROFIBUS DP - 32 Outputs - Connector M12), SI Unit Output Polarity: N (-COM), Stations: 6 Stations, P, E Port Entry: B (Both Sides 2~16 Stations), SUP/EXH Block Assembly: S (Internal Pilot, Built-in Silencer), A, B Port: C6 (ø6 One-touch Fitting)

Series: 3 (JSY3000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: NA (PROFIBUS DP - 32 Outputs - Connector M12), SI Unit Output Polarity: N (PNP, Negative Common), Valve Stations: 16 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A,B Port Size: C6 (ø6 One-touch Fitting)