For connecting at least 1 sensor other PSE530 series. Automatic identification function release For connecting only PSE530 series. Initial setting Selection of Pressure range, Output style, Response time and Pressure setting method. Pressure Setting Input of set value for pressure to perform switch output.

Multi-Channel Controller Series PSE200 Pressure Sensor Series PSE530 1 A single controller monitors up to 4 pressure sensors. 2 4 MPa kPa OUT1 OUT2 CH 1 2 3 4 PRESSURE SET 3 1 A single controller monitors 2 4 MPa kPa OUT1 OUT2 CH 1 2 3 4 PRESSURE SET 3 Multi-Channel Controller Series PSE200 Pressure Sensor Series PSE530 Space saving 1 40mm MPa kPa OUT1 76% OUT2 CH 1 2 3 4 PRESSURE SET reduction

For connecting at least 1 sensor other than PSE530 series. For connecting only PSE530 series. OUT1 OUT2 P_1 P_3 P_2 P_4 These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of "Caution", " Warning" or "Danger".

Specifications Series PSE200A PSE533 PSE543 PSE563 PSE573 PSE530 PSE540 PSE560 PSE570 Applicable SMC pressure sensor PSE550 PSE531 PSE541 PSE561 PSE532 PSE564 PSE574 PSE575 PSE576 PSE577 Rated pressure range 0 to 2 kPa 0 to 101 kPa 100 to 100 kPa 0 to 100 kPa 0 to 500 kPa 0 to 1 MPa 0 to 2 MPa 0 to 5 MPa 0 to 10 MPa Display/Set pressure range 0.2 to 2.1 kPa 10 to 105 kPa 105 to 105 kPa 10

Applicable pressure sensor PSE531 PSE541 PSE561 PSE530 PSE560 PSE564 PSE550 PSE532 101 to 101 10 to 101 10 to 100 0.1 to 1 50 to 500 0.2 to 2.00 Set (differential) pressure range 5%R.D.

. + PSE530 PSE540 PSE560 PSE570 PSE533 PSE543 PSE563 PSE573 12 to 24 VDC PSE531 PSE541 PSE561 Black OUT Applicable pressure sensor PSE532 (Current output) Load Blue DC(-) PSE300 series (PSE5##) PSE310 series (PSE5##-28) NOTE The direct current power supply to be used should be UL approved as follows: Circuit (of Class 2) which is of maximum 30 Vrms (42.4 V peak), with UL1310 Class 2 power

PSE530 and PSE532 are CE and RoHS compliant, with IP40 enclosure ratings. Economical remote pressure sensor in a small IP40 package; Power supply requirement: 12 to 24 VDC; 1 to 5V analog output; Accuracy: ±2% of F.S.; Repeatability: ±1% of F.S.; Port sizes: M5 x 0.8 male; ø6mm or ø1/4" plug-in connector for fittings

PSE530 and PSE532 are CE and RoHS compliant, with IP40 enclosure ratings. Economical remote pressure sensor in a small IP40 package; Power supply requirement: 12 to 24 VDC; 1 to 5V analog output; Accuracy: ±2% of F.S.; Repeatability: ±1% of F.S.; Port sizes: M5 x 0.8 male; ø6mm or ø1/4" plug-in connector for fittings

-wire oval cable (0.15 mm2) Sensor cable With sensor cable 42.4 g 42.7 g 49.3 g 41.4 g 41.6 g 43.3 g 44.1 g Weight Without sensor cable 2.9 g 3.2 g 9.8 g 1.9 g 2.1 g 3.8 g 4.6 g 16-3-25 4 Series PSE540 Internal Circuit PSE54 Voltage output type 1 to 5 V Output impedance Approx. 1 k Brown DC (+) Main circuit 1 k Black OUT 10 to 24 VDC + (Analog output) Load Blue DC () Dimensions PSE5R04 R06

PSE54(A)-R04 PSE54(A)-R06 A 4 6 B 18 20 PSE54(A)-IM5 PSE54(A)-IM5H -14No.PS-OMG0004-D Revision history A: For B: Complete revision C: Limited warranty and Disclaimer and measurement laws are added.

Piping specifications Lead wire length R06 R07 6 reducer 1/4" reducer L 3 m Switch Specifications PS1000/PS1100 PS1200 58 (0.4) 0 psi (MPa) psi (kPa) 29 (0.2) 7.25 (50) Set pressure Set pressure 0 14.5 (100) t t 14.5 (0.1) The switch turns ON when the set pressure is reached or exceeded. The switch turns ON when at the set pressure or below.

Caution PS 10 00 R06 L Port size R06: 6 reducer, R07: 1/4 reducer OFF Do not touch the terminals and connectors while the power is on. Otherwise electric shock, malfunction or damage to the product can result.

-600 KN-R06-800 KN-R10-800 D H1 A L1 Copper extension nozzle/KNL (mm) Model Nozzle size D Outside diameter L1 1.5 2 2 2.5 2.5 3 1.5 2 2 2.5 2.5 3 6 6 8 8 10 10 6 6 8 8 10 10 300 300 300 300 300 300 600 600 600 600 600 600 KNL3-06-150 KNL3-06-200 KNL3-08-200 KNL3-08-250 KNL3-10-250 KNL3-10-300 KNL6-06-150 KNL6-06-200 KNL6-08-200 KNL6-08-250 KNL6-10-250 KNL6-10-300 O.D

Pressure: 2 (For Low Pressure (0~101kPa)), Port Size: R06 (R06 Reducer Type), Option: L (Sensor Cable)

Pressure: 2 (For Low Pressure (0~101kPa)), Port Size: R06 (R06 Reducer Type), Option: C2L [Connector for Pressure Sensor Controller (1pc)+Sensor Cable (3m)]

Pressure: 3 (For Compound Pressure (-101~101kPa)), Port Size: R06 (R06 Reducer Type), Option: C2L [Connector for Pressure Sensor Controller (1pc)+Sensor Cable (3m)]

Pressure: 3 (For Compound Pressure (-101~101kPa)), Port Size: R06 (R06 Reducer Type), Option: L (Sensor Cable)