Y and 4 hours at Z JIS D1061 as standard Impact Resistance 30G. 3 times at each axis Extension Cable (option) 5m, 10m, 15m, 20m (Connector: R04-P8F7. 3. Tajima Musen Denki Company) C O N T R O L L E R SPECIFICATIONS The ML2B Series can be controlled from either CEU1 or CEU2 Series Controllers. For detailed Controller Specification and Accessories refer to CE1 & CE2 pages.
Y and 4 hours at Z JIS D1061 as standard Impact Resistance 30G. 3 times at each axis Extension Cable (option) 5m, 10m, 15m, 20m (Connector: R04-P8F7. 3. Tajima Musen Denki Company) C O N T R O L L E R SPECIFICATIONS The ML2B Series can be controlled from either CEU1 or CEU2 Series Controllers. For detailed Controller Specification and Accessories refer to CE1 & CE2 pages.
Cable Length: 15m, Connector: C [Extension Cable (w/R04-P8F7.3 Connector)+ Connector(R04-J8M7.3)]
Cable Length: 20m, Connector: C [Extension Cable (w/R04-P8F7.3 Connector)+ Connector(R04-J8M7.3)]
Cable Length: 10m, Connector: C [Extension Cable (w/R04-P8F7.3 Connector)+ Connector(R04-J8M7.3)]
Cable Length: 5m, Connector: C [Extension Cable (w/R04-P8F7.3 Connector)+ Connector(R04-J8M7.3)]
Model (Sensor unit: Standard model number) ZK2-PS1-A (PSE541) ZK2-PS3-A (PSE543) Rated pressure range 0 to 101 kPa 100 to 100 kPa Proof pressure 500 kPa Output voltage 1 to 5 VDC Output impedance Approx. 1 k Power supply voltage 10 to 24 VDC 10%, Ripple (p-p) 10% or less Current consumption 15 mA or less Accuracy 2% F.S. (Ambient temperature at 25C) Linearity 0.4% F.S.
Series Pressure range 0~-101kPa PSE541 Vacuum pressure -101kPa 0Pa For air -100~100kPa PSE543 Compound pressure 100kPa -100kPa
mm 0.3 0.4 0.5 0.6 2 MPa 0.20.55 0.30.55 MPa 0.35 0.4 0.35 0.45 0.35 0.5 L/minANR 3.5 4 6.5 8.5 10 18 /minANR 2 3.5 4.5 7 kPa -85 -90 1 20.5MPa URL http://www.smcworld.com Best Pneumatics No.4 P877898 30m 2 130mm ZB1-PS-A ZB1-PS1-A ZB1-PS3-A PSE541 PSE543 0-101kPa -100100kPa 500kPa DC15V 1k DC1024V10P-P10 15mA 2FS 25 0.4FS 0.2FS 0.8FS 2FS25 O HNBR 2 3 3m0.9mm 2.7X3.2mm
New Products Guide 1 Directional Control Valves Actuators Vacuum Equipment CAT.E00-6A INDEX New Products Guide 1 Directional Control Valves 5 Port Solenoid Valve Fieldbus System (For Input/Output) 2/3 Port Mechanical Valve Series SY3000/5000/7000 Series EX600 Series VM100/200 P .6 P .264 P .322 Actuators Foot Pedal Type 5 Port Mechanical Valve XT34-60/67 Air Cylinder Air Cylinder Series CJ2
Series Pressure range 0~-101kPa PSE541 Vacuum pressure -101kPa 0Pa For air -100~100kPa PSE543 Compound pressure 100kPa -100kPa 1-16-4 Shimbashi, Minato-ku, Tokyo 105-8659, JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2002 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer
P-1 = A (A B) / 4 H-1 = (A B) / 2 A = Maximum pressure value B = Minimum pressure value For low differential pressure For low pressure For compound pressure PSE533 PSE543 PSE563 For positive pressure For vacuum Pressure range C Display calibration function This function eliminates slight differences in the output values and allows uniformity in the numbers displayed.
Work 1 Work 2 Work n Atmosphere A = Maximum pressure value B = Minimum pressure value P-1 = A (A B) / 4 H-1 = (A B) / 2 For compound pressure PSE533 PSE543 PSE563 For low differential pressure For low pressure For vacuum For positive pressure Pressure range C Display calibration function This function eliminates slight differences in the output values and allows uniformity in the numbers
Sensor Range: 0 [Positive pressure (0 to 1 MPa)], Accuracy: ±2% F.S., Port Size: R04 (Ø4 Plug-In Reducer), Output Specification: N (NPN open collector 1 output), Lead Wire Termination: Basic, Set Value: P (Normal Output), OUT1 Set Value: 005 (0.5 MPa, −50 kPa, 50 kPa), OUT1 Hysteresis: 5 (0.05 MPa, 5 kPa, 5 kPa)
Sensor Range: 0 [Positive pressure (0 to 1 MPa)], Accuracy: ±2% F.S., Port Size: R04 (Ø4 Plug-In Reducer), Output Specification: N (NPN open collector 1 output), Lead Wire Termination: Basic, Set Value: P (Normal Output), OUT1 Set Value: 004 (0.4 MPa, −40 kPa, 40 kPa), OUT1 Hysteresis: 4 (0.04 MPa, 4 kPa, 4 kPa)
Endurance 10 G; X, Y, Z directions, 3 times each CE2 Impact resistance 250 g or less Weight ML2B 3-point Preset Counter/Dimensions C J G5-S CV MVGQ CC RB J D-X 20Data 10-12-31 31 Series CEU Extension Cable How to Order CE1-R Cable length Suffix 05 10 15 20 Extension cable Nil 5 m 10 m Extension cable & connector C 15 m 20 m Extension cable CE1R Stroke reading cylinder side connector (unit) R04
CEU5 Control signal input COM Control signal input or 1 k (Select Reset/ Hold/Bank) Power supply (24 or 12 VDC) 2.2 k Extension Cable How to Order CE1-R Cable length 05 10 15 20 Suffix Extension cable Nil 5 m 10 m Extension cable & connector C 15 m 20 m Extension cable CE1R Stroke reading cylinder side connector (unit) R04-J8M7.3 (Made by Tajimi Electronics Co., Ltd.)
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Stroke reading cylinder side connector (unit) R04-J8M7.3 (Made by Tajimi Electronics Co., Ltd.)
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Stroke reading cylinder side connector (unit) R04-J8M7.3 (Made by Tajimi Electronics Co., Ltd.)
Sensor Range: 0 [Positive Pressure (0~1MPa)], Accuracy: A (±1%F.S.), Port Size: R04 (Ø4 Plug-In Reducer), Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]