Sensor Range: 1 [For Vacuum (0~-101kPa)], Accuracy: ±2% F.S., Port Size: R06 (Ø6 Plug-In Reducer), Output Specification: L (IO-Link/Switch: 1 output), Lead Wire Termination: S (With M12-4 pin connector, 500 mm)
Specifications Series PSE200A PSE533 PSE543 PSE563 PSE573 PSE530 PSE540 PSE560 PSE570 Applicable SMC pressure sensor PSE550 PSE531 PSE541 PSE561 PSE532 PSE564 PSE574 PSE575 PSE576 PSE577 Rated pressure range 0 to 2 kPa 0 to 101 kPa 100 to 100 kPa 0 to 100 kPa 0 to 500 kPa 0 to 1 MPa 0 to 2 MPa 0 to 5 MPa 0 to 10 MPa Display/Set pressure range 0.2 to 2.1 kPa 10 to 105 kPa 105 to 105 kPa 10
Without pressure sensor Note 1) P1 PSE541 P1A PSE541A P3 PSE543 P3A PSE543A Electrical entry B KQ2P-04 L L plug connector, with 0.3 m lead wire, with light/surge voltage suppressor Note 1) One-touch fittings are plugged when the pressure sensor is mounted. Note 2) This pressure switch detects pressure and converts the data into analog output.
. + PSE530 PSE540 PSE560 PSE570 PSE533 PSE543 PSE563 PSE573 12 to 24 VDC PSE531 PSE541 PSE561 Black OUT Applicable pressure sensor PSE532 (Current output) Load Blue DC(-) PSE300 series (PSE5##) PSE310 series (PSE5##-28) NOTE The direct current power supply to be used should be UL approved as follows: Circuit (of Class 2) which is of maximum 30 Vrms (42.4 V peak), with UL1310 Class 2 power
PSE541 and PSE543 are remote vacuum sensors with a 1 to 5V analog signal output. The sensor construction optimizes space savings, for tight, constrained spaces. PSE541 is for a low vacuum (-101 to 0 kPa), while PSE543 is for compound pressure (-100 to 100 kPa).
PSE541 and PSE543 are remote vacuum sensors with a 1 to 5V analog signal output. The sensor construction optimizes space savings, for tight, constrained spaces. PSE541 is for a low vacuum (-101 to 0 kPa), while PSE543 is for compound pressure (-100 to 100 kPa).
Piping specifications Lead wire length R06 R07 6 reducer 1/4" reducer L 3 m Switch Specifications PS1000/PS1100 PS1200 58 (0.4) 0 psi (MPa) psi (kPa) 29 (0.2) 7.25 (50) Set pressure Set pressure 0 14.5 (100) t t 14.5 (0.1) The switch turns ON when the set pressure is reached or exceeded. The switch turns ON when at the set pressure or below.
Caution PS 10 00 R06 L Port size R06: 6 reducer, R07: 1/4 reducer OFF Do not touch the terminals and connectors while the power is on. Otherwise electric shock, malfunction or damage to the product can result.
Applicable fitting size (D) PSE53-R06 6 mm PSE53-R07 1/4 inch With sensor cable -14No.PS-OME0004-G Revision history A: For B: Change template. C: Complete revision. D: Modified errors in text. E: Measurement laws are added. F: Modified errors in text. [October 2017] G: Contents revised in several places.
Pressure: 2 (For Low Pressure (0~101kPa)), Port Size: R06 (R06 Reducer Type)
Pressure: 2 (For Low Pressure (0~101kPa)), Port Size: R06 (R06 Reducer Type), Option: L (Sensor Cable)
Pressure: 0 [Positive Pressure (0~1MPa)], Port Size: R06 (R06 Reducer Type), Option: L (Sensor Cable)
Pressure: 2 (For Low Pressure (0~101kPa)), Port Size: R06 (R06 Reducer Type), Option: C2L [Connector for Pressure Sensor Controller (1pc)+Sensor Cable (3m)]
Pressure: 0 [Positive Pressure (0~1MPa)], Port Size: R06 (R06 Reducer Type)
Pressure: 0 [Positive Pressure (0~1MPa)], Port Size: R06 (R06 Reducer Type), Option: C2L [Connector for Pressure Sensor Controller (1pc)+Sensor Cable (3m)]
Pressure: 1 (For Vacuum (0~101kPa)), Port Size: R06 (R06 Reducer Type)
Pressure: 3 (For Compound Pressure (-101~101kPa)), Port Size: R06 (R06 Reducer Type)
Pressure: 3 (For Compound Pressure (-101~101kPa)), Port Size: R06 (R06 Reducer Type), Option: C2L [Connector for Pressure Sensor Controller (1pc)+Sensor Cable (3m)]
Pressure: 3 (For Compound Pressure (-101~101kPa)), Port Size: R06 (R06 Reducer Type), Option: L (Sensor Cable)
Pressure: 1 (For Vacuum (0~101kPa)), Port Size: R06 (R06 Reducer Type), Option: C2L [Connector for Pressure Sensor Controller (1pc)+Sensor Cable (3m)]