Output Specification: L2 (IO-Link/Switch output 1 + Switch output 2), Units specification: w/Units Selection Function, Piping Specification: 01 (R 1/8), Option 1: w/o Lead Wire, Option 2: A (Bracket)
Output Specification: L2 (IO-Link/Switch output 1 + Switch output 2), Units specification: w/Units Selection Function, Piping Specification: 01 (R 1/8), Option 1: w/o Lead Wire, Option 2: B (Panel Mount Adapter)
Output Specification: L2 (IO-Link/Switch output 1 + Switch output 2), Units specification: M (SI units only), Piping Specification: 01 (R 1/8)
Output Specification: RT (Switch output 1 + Switch output 2 + Analog voltage output), Units specification: M (SI units only), Piping Specification: 01 (R 1/8), Option 1: W (Lead Wire w/Connector, 2m Waterproof), Option 2: D (Panel Mount Adapter + Front Protection Cover)
Cylinder: MXY8-100 Cushion: Rubber stopper Mounting: Horizontal wall mounting Average speed: Va = 300 [mm/s] Load weight: W = 0.2 [kg] L2 = 40 mm L3 = 50 mm Model to be used Type of cushion Mounting orientation Average speed Va (mm/s) Load weight W (kg) Overhang Ln (mm) W L3 + A3 L2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650
Cylinder: MXY8-100 Cushion: Rubber stopper Mounting: Horizontal wall mounting Average speed: Va = 300 [mm/s] Load mass: W = 0.2 [kg] L2 = 40 mm L3 = 50 mm Model to be used Type of cushion Mounting orientation Average speed Va (mm/s) Load mass W (kg) Overhang Ln (mm) W L3 + A3 L2 Load Mass 2 V = 1.4 Va V = 1.4 x 300 = 420 Correction factor (Reference value) Find the collision speed
Load mass (kg) m1 m2 Moment (Nm) m3 M3 = F3 x L3 F3 F2 M1 = F1 x L1 F1 M2 = F2 x L2 L2 L1 L3 Calculation of Guide Load Factor 1) Maximum load mass (1), static moment (2), and dynamic moment (3) (at the time of impact with stopper) must be examined for the selection calculations. To evaluate, use a (average speed) for (1) and (2), and (collision speed = 1.4a) for (3).
Wall mounting y Wd: Workpiece (500 g) P.1230 x y Wc: MHL2-16D1(795 g) x z Wa: Connection plate t = 10 (880 g) x MY1MW40-500 3. Ceiling mounting 4.
Single phase 200 to 230 VAC, 50/60 Hz Connection terminal: L1, L2 Three phase 200 to 230 VAC, 50/60 Hz Connection terminal: L1, L2, L3 L2 L3 L1C Control power supply Connect the control power supply.
Load mass (kg) m1 m2 m3 Moment (Nm) M3 = F3 x L3 F3 M1 = F1 x L1 F1 M2 = F2 x L2 F2 L1 L2 L3
-X 20m2 m3 Data Moment (Nm) M1 = F1 x L1 F1 F2 M3 = F3 x L3 F3 M2 = F2 x L2 L1 L2 L3 Maximum Load Weight Select the load from within the range of limits shown in the graphs. Note that the maximum allowable moment value may sometimes be exceeded even within the operating limits shown in the graphs. Therefore, also check the allowable moment for the selected conditions.
M1 = F1 x L1 M2 = F2 x L2 M3 = F3 x L3 F2 F1 F3 LC6m LC6m L1 E-MY2C P.1127 L2 L3 E-MY2H LZm LZm P.1133 E-MY2HT LC3F2 LC3F2 Caution Xm Xm Select the required model by taking into consideration the operating condition specifications and any possible specification changes that may occur during operation.
Load weight (kg) m1 m2 m3 Moment (Nm) M1=F1 x L1 F1 F2 M3=F3 x L3 F3 M2=F2 x L2 L1 L2 L3 Maximum load weight
Load (kg) m1 m2 m3 Moment (Nm) M3 = F3 x L3 F3 M1 = F1 x L1 F1 M2 = F2 x L2 F2 L1 L2 L3
Load weight (kg) m1 m2 m3 Moment (Nm) M3 = F3 x L3 F3 M1 = F1 x L1 F1 M2 = F2 x L2 F2 L1 L2 L3
-X 20m2 m3 Data Moment (Nm) M1 = F1 x L1 F1 F2 M3 = F3 x L3 F3 M2 = F2 x L2 L1 L2 L3 Maximum Load Weight Select the load from within the range of limits shown in the graphs. Note that the maximum allowable moment value may sometimes be exceeded even within the operating limits shown in the graphs. Therefore, also check the allowable moment for the selected conditions.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com m1 m2 m3 Moment (Nm) M3 = F3 x L3 F3 M1 = F1 x L1 F1 M2 = F2 x L2 F2 L1 L2 L3
Output Specification: L2 (IO-Link/Switch output 1 + Switch output 2), Units specification: M (SI units only), Piping Specification: 01 (R 1/8), Option 1: W (Lead Wire w/Connector, 2m Waterproof)
Output Specification: L2 (IO-Link/Switch output 1 + Switch output 2), Units specification: M (SI units only), Piping Specification: 01 (R 1/8), Option 1: W (Lead Wire w/Connector, 2m Waterproof), Option 2: A (Bracket)
How to Order X214 01 S AS 2 2 0 0 Body size Option Port size Model Thread type Control method Speed Controller with One-touch Fitting Elbow Type, Metal Body/Series AS Refer to How to Order in page 15-9-43 for standard specifications. How to Order X214 2 2 1 01 06 S AS 1FG Body size Option Applicable tubing O.D.