SMC Corporation of America
Elite Part Number Search
Search Results "PSH-L2-M-01-W"

17 8.5 24 2 x 4.3 (For mounting) 37.5 4 Manual override A B B A P R 41 0.5 G: Approx. 300 H: Approx. 600 (Lead wire length) 63.6 [65.8] (Light/surge voltage suppressor) 50.1 [57.1] + 45 8.5 34.7 21.5 6 6 45.5 17 17 15 1/8 (P, R port) 32 24 L plug connector (L): 10-SYJ5143-L-01 M plug connector (M): 10-SYJ5143-M-01 DIN terminal (D, Y): 10-SYJ5143-01 M8 connector (WO): 10-SYJ5143-WO-01 D Y

VA (2.1 W)/50 Hz, 2.3 VA (1.5 W)/60 Hz AC VFS1320-D-01 1.8 W (2.04 W: With light/surge voltage suppressor) Power consumption (DC) Grommet, Grommet terminal, Conduit terminal, DIN terminal Electrical entry VFS1120-G-01-F Note 1) Use dry air at low temperatures.

Speed controller Silencer Tube x Length Speed controller Silencer SX3140-01 SX3120-C6 AS3001F-06 AN110-01 AS2051F-06 AN120-M5 T0604 x 1 m T0806 x 1 m AS3001F-08 T0604 x 1 m T0806 x 1 m AS3001F-08 SX5140-02 SX5120-01 AS3001F-06 AS3001F-06 AN101-01 AN101-01 AS4001F-10 T0604 x 1 m T1075 x 1 m T1209 x 1 m AS3001F-06 T0604 x 1 m AS3001F-06 T1075 x 1 m AS4001F-10 SX7140-03 SX7120-02 SV AS200-02

Cable length VVFS2000-30A-1 VVFS2000-30A-2 VVFS2000-30A-3 VVFS2000-30A-4 VVFS2000-30A-5 VVFS2000-30A-6 VVFS2000-30A-7 1.5 m 3 m 5 m 7 m 10 m 15 m 20 m 1.5 m 3 m 5 m 8 m 10 m 15 m 30 m VVZS3000-21A-1 VVZS3000-21A-2 VVZS3000-21A-3 VVZS3000-21A-4 VVZS3000-21A-5 VVZS3000-21A-6 VVZS3000-21A-7 Plug 206837-1 1 pc. Cable clamp 206138-1 1 pc. Socket 66101-2 24 pcs.

Description Zinc die-casted Zinc die-casted Body Body w w Stainless steel Aluminum/HNBR Spool/Sleeve Spool valve e e Resin Resin Piston Piston r Pilot valve assembly r Pilot valve assembly Note) L M G 2 Note) L M G 2 VQ111(H) (Y) Voltage 1 to 6 VQ111(H) (Y) Voltage 1 to 6 Single Single VQ110L L M 2 VQ110L L M 2 Double (Latching) Double (Latching) Voltage 1 to 6 Voltage 1 to 6 Note) L M G

Load factor: ( (Load weight x 9.8)/Theoretical force) x 100% Conditions Series CJ2 Series CM2 6 x 1 m AS3301F-06 8 x 1 m AS3301F-08 AN110-01 Series MB/CA2 Series CJ2 Series CM2 4 x 1 m Series MB/CA2 Body ported Tubing bore x Length Speed controller Silencer Base mounted Tubing bore x Length Speed controller Silencer AS2301F-04 6 x 1 m 4 x 1 m AS1301F-04 AN120-M5 SYJ5120-M5 SYJ5140-01 AN101

hose H1 H2 L2 M L1 (mm) Effective area mm H Width across flats Model H Width across flats Minimum bore Applicable hose I.D.

EX260 Serial transmission Calculation of dimensions L1 = 12.5 x n1 + 16 x n2 + 88.7 L2 = 12.5 x n1 + 16 x n2 + 48 M = L1/12.5 + 1 Remove all numbers after the decimal.

(For manifold type 20, 21R) 1 SYJ7 2 5 M 01 Body ported SYJ7 4 5 M 01 1 Base mounted Manual override 3 port Thread type Nil: Non-locking push type D: Push-turn locking slotted type Coil specifications F Nil Rc Nil Standard G N T NPT NPTF With power saving circuit (24, 12 VDC only) T Power saving circuit is not available in the case of D, DO, W type.

Connector for unit (Plug) 6 y t y t EX600-DXlB EX600-DYlB EX600-DXlCl q w q w e q w er e y t y t y t EX600-DXlD EX600-DXlE EX600-DYlE EX600-DMlE EX600-DXlF EX600-DYlF EX600-DMlF Analog Unit q w e q w e No.

T0604 x 1 m AS3001F-06 AN110-01 T0604 x 1 m AS3001F-06 VQZ1151-01 VQZ1121-C6 T0806 x 1 m AS3001F-08 VQZ2151-02 VQZ2121-C6 AN200-02 T1075 x 1 m AS4001F-10 AN300-03 T0604 x 1 m AS3001F-06 T1209 x 1 m AS4001F-12 VQZ3121-C6 VQZ3151-03 909 Series VQZ Model Selection Sonic conductance C [dm3/(sbar)] Type of actuation Voltage Electrical entry Light/surge voltage suppressor Manual override VQZ1000

Nil A B C D q w e q w q w w q e q w The number inside indicates the combination order counted from the inlet side.

Connection L2 M d A Effective area (mm2) Weight (g) L1 thread R Model 1 8 1 4 1 8 1 4 3 8 1 8 1 4 3 8 1 8 1 4 3 8 1 4 3 8 1 2 1 4 3 8 1 2 1 4 3 8 1 2 1 4 3 8 1 2 KFH04-01 KFH04-02 KFH06-01 KFH06-02 KFH06-03 KFH08U-01 KFH08U-02 KFH08U-03 KFH08N-01 KFH08N-02 KFH08N-03 KFH10U-02 KFH10U-03 KFH10U-04 KFH10N-02 KFH10N-03 KFH10N-04 KFH12U-02 KFH12U-03 KFH12U-04 KFH12N-02 KFH12N-03 KFH12N-04 10 10

A Drain cock with barb fitting: 6 x 4 nylon tube W AC25 to 60 G M G M Note 3) Name plate, caution plate for bowl, and pressure gauge in imperial units (PSI, F) Z AC10 to 60 M G A G M When more than one specification is required, indicate in ascending alphanumeric order.

PS Applicable stations (For F, P, J, S kit) 01 Station 1 PW 24 Station 24 Construction L kit: Lead wire kit Lead wire length 0.6 m L kit: Lead wire kit Lead wire length 1.5 m L kit: Lead wire kit Lead wire length 3 m Note 1) F0: Nil Note 2) Specify from 01 to 16 for S kit.

with lead wire M plug connector without connector (1.0 W) Note) Nil Standard type VQZ High pressure type Low wattage type (1.5 W) (0.5 W) H VQD Y Note) For power consumption of AC type, refer to page 2-4-218.

and lock override. 22.8 (GZ, GS: 23.8) [23.8] (Non-locking) Manual override 85.6 (GZ, GS: 87.6) [87.6] G: 300 H: 600 87.2 (GZ, GS: 88.6) [90.6] (Lead wire length) 51.5 [58] 48.6 8.5 45 39.1 32.5 21.5 6 6 10 4-Rc(PT)1/8 (Piping port) 17 17 15 45.5 24 32 [ ] for AC L plug connector (L): SYJ5240-lLll-01 M plug connector (M): SYJ5240-lMll-01 2-4.3 (Mounting holes) 2-4.3 (Mounting holes) 24