MODEL EW53 3-Way Normally Closed ATMOSPHERE EXHAUST EW53GG8DCCP EW53HH8DCCP EW53HJ8DCCP EW53JJ8DCCP EW53KK8DCCP 250 150 150 100 50 250 150 150 100 50 .022 .055 .055 .075 .150 .020 .048 .075 .075 .150 DE-ENERGIZED ENERGIZED MODEL EW53 3-Way Normally Closed WITH PIPED EXHAUST ** EW53GG8XCCP EW53HH8XCCP EW53HJ8XCCP EW53JJ8XCCP EW53KK8XCCP 250 150 150 100 50 250 150 150 100 50 .022 .055 .055
Lx = 400 mm, Ly = 250 mm, Lz = 1500 mm 4.
Applicable air dryer Capacity Type Inlet voltage Outlet voltage Weight 380, 400, 415 VAC (50 Hz) 380 to 400, 400 to 415, 415 to 440 VAC (60 Hz) 295 250 220 IDF-TR2000-10 IDF22E-20 IDF37E-20 2 kVA 200 VAC (50 Hz) 200, 220 VAC (60 Hz) Singlephase Singleturn 20 kg 220 15 270 10 4 x 10 IDF-TR2000-11 440, 460 VAC (50 Hz) 440 to 460, 460 to 500 VAC (60 Hz) 250 290 [mm] IDF-TR4000-5,6,7 Specifications
Note 1) 110 VAC and 115 VAC types and 220 VAC and 230 VAC types are common respectively.
Note 1) 110 VAC and 115 VAC types and 220 VAC and 230 VAC types are common respectively.
Applicable strokes: 250, 350, 450, 550, 650, 700, 750, 850, 900, 950, 1050, 1100, 1150, 1250, 1300, 1350, 1400, 1450 Example) LJ1H3031PD-250-F2-X2 Allowable Moment (Nm) Allowable static moment Allowable dynamic moment Pitching Rolling Yawing Mounting orientation Load movement direction 117 137 123 Model LJ1H30 Horizontal/Lateral Horizontal/Lateral Lateral Horizontal a Mep a = 1000 2000 L1
VAC, 50/60 Hz 1 4 4 Light/Surge voltage suppressor 5 24 VDC 12 VDC Body type 6 Nil None Z With light/surge voltage suppressor S With surge voltage suppressor 6 For type 60 and 61 manifolds 7 240 VAC, 50/60 Hz 9 Other 7 For type 70 and 71 manifolds Option L, M plug connector: Max. 220 VAC Indicator light is not available for grommet type.
0 50 100 150 200 250 Supply pressure (kPa) Supply pressure (kPa) Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 1.5 Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 1.5 0.6 0.4 0.5 mm 0.25 mm 0.5 Detection distance (mm) Detection distance (mm) 0.3 0.4 0.3 0.2 0.15 mm 0.2 0.15 mm 0.1 0.1 0.03 mm 0.01 mm 0 0 0 50 100 150 200 250 0 50 100 150 200 250 Supply pressure (kPa
, 300, 350, 400, 450, 500 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 80 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 Fluid Air Proof Ppressure 1.5MPa / 214PSI Max Operating Pressure
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 219 219 220 222 223 224 225 226 227 229 233 233 234 235 236 237 238 239 240 241 245 245 246 247 248 249 250 251 252 253 255 255 256 257 258 259 260 261 262 Dimensions .
Note 2) When the valve is a standard (dust-protected) specification, it is not compatible with 200 or 220 VAC.
CXWM20-300 107 264 20 90 570 252 304 556 584 119.5 289 20 90 620 277 329 606 634 132 314 20 90 670 302 354 656 684 Model F 38 L 240 K 28 P 220 Q 543 S 227 SS 296 Z 523 ZZ 563 CXWM32-225 CXWM32-250 38 265 28 245 593 252 321 573 613 CXWL series: 16, 25 (mm) Model F 115.5 L 239 K 41 P 90 Q 560 S 227 SS 321 Z 548 ZZ 584 CXWL16-225 CXWL16-250 CXWL16-275 128 264 41 90 610 252 346 598 634 140.5
Red (DC) Blue 100 VAC 110 VAC 200 VAC 220 VAC Red Blue 100 VAC 110 VAC Red 200 VAC 220 VAC Push type (Tool required) Push down on the manual override button with a small screwdriver until it stops. Release the screwdriver and the manual override will return.
0.3 0.1 1.0 0.3 0.1 5/64 2 3 5 2 3 5 4 7 4 7 5 8 10 5 8 10 0.82 1.25 1.45 0.82 1.81 2.11 1.69 3.14 1.68 3.54 2.50 2.77 5.69 2.50 2.56 5.69 0.44 0.34 0.43 0.44 0.40 0.32 0.40 0.34 0.49 0.36 0.44 0.82 0.46 0.44 0.88 0.64 0.23 0.35 0.40 0.23 0.41 0.56 0.47 0.84 0.50 0.90 0.70 1.22 1.54 0.70 1.38 1.76 145 85 29 145 85 29 145 21 145 21 145 43 14 145 43 14 220 220 220 220 220 220 340 340 340 340
, 240/200 to 240VAC (50Hz) Power source 225 275 205 240 182 189 250 350 220 280 265 275 305 380 300 350 280 295 340 415 325 375 332 50Hz 60Hz 50Hz 60Hz 50Hz 50Hz 50Hz 100 VAC 200 VAC Power consumption (W) 220 to 240VAC 220VAC 240VAC JIS Symbol 10 (for 100VAC), 5 (for 200VAC) Air cooled R134a Circuit breaker (A) Note 3) Refrigerated air dryer Condenser Refrigerant Air connection Drain
Note 2) When the valve is a standard (dust-protected) specification, it is not compatible with 200 or 220 VAC.
Note 2) When the valve is a standard (dust-protected) specification, it is not compatible with 200 or 220 VAC.
4 1000st 900st 3 800st 700st 2 600st st: Stroke (mm) 400st 500st 1 100st 200st 300st 0 0 50 100 150 200 250 300 350 400 450 500 550 600 Allowable end load F (N) MGGM 100Stroke 8 (Slide bearing type) 7 6 Deflection Y (mm) 5 1300st 1200st 4 1100st 1000st 3 900st 800st 2 600st 700st st: Stroke (mm) 400st 500st 1 100st 200st 300st 0 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750
Long Stroke Bracket Mounting Stroke Stroke range (mm) Bore size (mm) Bore size (mm) Bracket mounting stroke 100 st or more 250 to 400 20 20 125 st or more 350 to 500 25 25 150 st or more 350 to 600 32 32 200 st or more 350 to 800 40 40 250 st or more 350 to 1000 50 50 8-21-32 32 Series MGG Guide Cylinder With End Lock Front mounting flange style: MGGF 63 to 100 M N HR HN (MAX.) 4-O Bracket
KNL6-06-200 KNL6-08-200 KNL6-08-250 KNL6-10-250 KNL6-10-300 O.D.