(Including bracket, screw) -X Auto switch mounting screw M2.5 x 10 l (D-E7A/E8A) M2.5 x 12 l (D-M5/M5W/M5T) Applicable bore size (mm) 6 BP-1 10 BP-1 15 BP-1 20Cylinder series CDJP-D 1. Insert the auto switch mounting nut into the auto switch mounting groove and then set the switch at the mounting position by sliding. 2.
(Including bracket, screw) -X Auto switch mounting screw M2.5 x 10 l (D-E7A/E8A) M2.5 x 12 l (D-M5/M5W/M5T) Applicable bore size (mm) 6 BP-1 10 BP-1 15 BP-1 20Cylinder series CDJP-D 1. Insert the auto switch mounting nut into the auto switch mounting groove and then set the switch at the mounting position by sliding. 2.
(Including bracket, screw) CA2 Auto switch mounting screw M2.5 x 10 l (D-E7A/E8A) M2.5 x 12 l (D-M5/M5W/M5T) Applicable bore size (mm) 6 BP-1 10 BP-1 15 BP-1 CS1 Cylinder series CDJP-D 1. Insert the auto switch mounting nut into the auto switch mounting groove and then set the switch at the mounting position by sliding. 2.
(Including bracket, screw) DAuto switch mounting screw M2.5 x 10 l (D-E7A/E8A) M2.5 x 12 l (D-M5/M5W/M5T) Applicable bore size (mm) 6 BP-1 10 BP-1 15 BP-1 -X Cylinder series CDJP-D 1. Insert the auto switch mounting nut into the auto switch mounting groove and then set the switch at the mounting position by sliding. 2.
Weight calculation m2 = d x e x f x Relative density m2 = 4 x 5 + 6 x 2.7 x 10-6 = 3.24 x 10-4 (kg) Inertial moment around Z2 axis IZ2 = {m2 (d2 x e2) / 12} x 10-6 IZ2 = {3.24 x 10-4 x (42 + 52) / 12} x 10-6 = 1.11 x 10-9 (kg.m2) = 1.11 x 10-9 + 3.24 x 10-4 x 23.52 x 10-6 = 0.18 x 10-6 (kg.m2) Inertial moment around Z axis IB = IZ2 x m2r22 x 10-6 IB Thus, the total inertial moment is I
Set the mounting band perpendicularly to cylinder tube. 20 50 63 80 100 25 32 40 D-B7/B80 8 10 9 10 10 11 D-B73C/B80C D-C7/C80 8 10 9 10 10 11 D-C73C/C80C 8 10 9 10 10 11 D-B5/B64 11 11 MX Mounting correctly Mounting incorrectly 13 13 14 14 14 17 D-B59W 18 16 D-G79/K79 8 10 9 10 10 11 Auto Switch Mounting Bracket Part No.
SS3YJA3 Fill the same as SS3YJ3. Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with the manifold base model no. (Example) SS3YJA3-41-03-M3 . 1 set SYJA314. 1 set SYJA324. 1 set SYJ300-10-2A . 1 set The asterisk denotes the symbol for assembly.
100 to 500 to 500 to 600 to 600 to 750 to 750 10 10 14 14 22 22 164.5 169 197 197 251 251 23 23 30 30 42 42 14 14 20 20 30 30 10.5 11 15 15 23 23 154 158 182 182 228 228 13 13 17 17 26 26 CX U L Z + Stroke RR ZZ + Stroke Without air cushion Overall length of front/rear flange, single/double clevis, and method for longitudinal mounting When there is no air cushion, the unit is equipped with
4H9 depth 3.5 +0.030 0 HA GA Section AA Section BB (mm) Model F 35 35 35 50 35 55 65 ZZ 99 99 99 111 131 177 231 M 71 71 71 83 103 149 203 Z 70 70 70 82 102 148 202 K 26.5 36.5 46.5 56.5 66.5 91.5 116.5 J 40 40 40 52 60 85 130 I 10 10 10 10 22 43 52 NN 2 2 2 3 3 4 5 HA 40 40 40 25 36 72 76 H 40 40 40 25 36 36 38 G 15 15 15 17 15 25 35 GA 15 15 15 42 51 61 111 N 4 4 4 4 6 6 6 NA 2 2 2 2 2
(Red Green Red) D-M5NW D-M5PW D-M5BW Auto switch model Wiring type 3-wire 2-wire Output type PNP NPN Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) Current consumption 10 mA or less Load voltage 28 VDC or less 24 VDC (10 to 28 VDC) Load current 40 mA or less 1.5 V or less (0.8 V or less at 10 mA load current) 5 to 40 mA 80
Ali d mensions in m Llimeters. 42
SS3YJA3 Fill the same as SS3YJ3. Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with the manifold base model no. (Example) SS3YJA3-41-03-M3 . 1 set SYJA314. 1 set SYJA324. 1 set SYJ300-10-2A . 1 set The asterisk denotes the symbol for assembly.
Uses the same manifold valve as the Series SYJ300 SS3YJA3 Specify the same manifold part number as SS3YJ3. Specify the part numbers for the valve(s), blank plate assembly and manifold base. SS3YJA3-41-03-M3 1 pc. SYJA3141 pc. SYJA3241 pc. SYJ300-10-2A 1 pc.
6 KA 78 79 77 77 S 16 12 10 8 D 25 18 14 12 E 2 2 2 2 F 40 32 25 20 30 22 22 18 23 0<23> 0 0 10 0 0 0 M5 x 0.8 depth 7.5 M5 x 0.8 depth 8 M14 x 1.5 M6 x 1 depth 12 12 12 1/4 1/4 3/8 1/2 58 58 27 27 32 41 14<12> 14<12> 10 10 10 10 23 20 20 20 11 11 58 72 20<17> 20<17> 16 16 71 71 13 16 89 110 7 7 10 10 55 69 80 100 10 10 10 10 32 38 50 60 150 150 182 182 18 18 22 26 90 90 108 108 20 20 25
Valve Mounting Direction: Solenoid on Side Opposite to A Port, Piping: 42 (Base Mounted), Stations: 2 Stations, A Port Size: M5 (Base Mounted M5X0.8), P R Port Thread: T (NPTF)
Valve Mounting Direction: Solenoid on Side Opposite to A Port, Piping: 42 (Base Mounted), Stations: 3 Stations, A Port Size: M5 (Base Mounted M5X0.8), P R Port Thread: T (NPTF)
Valve Mounting Direction: Solenoid on Side Opposite to A Port, Piping: 42 (Base Mounted), Stations: 4 Stations, A Port Size: M5 (Base Mounted M5X0.8), P R Port Thread: T (NPTF)
Valve Mounting Direction: Solenoid on Side Opposite to A Port, Piping: 42 (Base Mounted), Stations: 5 Stations, A Port Size: M5 (Base Mounted M5X0.8), P R Port Thread: T (NPTF)
Valve Mounting Direction: Solenoid on Side Opposite to A Port, Piping: 42 (Base Mounted), Stations: 6 Stations, A Port Size: M5 (Base Mounted M5X0.8), P R Port Thread: T (NPTF)