D side Coil voltage 1 100 VAC (50/60 Hz) 2 200 VAC (50/60 Hz) 3 110 VAC (50/60 Hz) 4 220 VAC (50/60 Hz) 5 24 VDC 6 12 VDC 461 VQ4000 Series Kit (Terminal block box kit) T 38 91 1/8" PE. port 18 18 17.2 PE 41.7 R1 R2 3 5 P 1 SMC 1/2" 1(P), 5(R1), 3(R2) port 1/4", 3/8" C6, C8, C10, C12, N7, N9, N11 4(A), 2(B) port M5 x 0.8 Ground screw 2 x G3/4 Conduit port 10.7 U side 129.5 126.5 3.5 163
/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] 220 VAC 50/60 Hz [230 VAC 50/60 Hz] With surge voltage suppressor (Non-polar type) T With light/surge voltage suppressor (Non-polar type) With surge voltage suppressor (Non-polar type) Power saving circuit is not available for W type.
25 30 50 Note) Available in units of 10 pieces.
SY100-30-3AS Z Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage R 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Lead wire length U Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm For AC voltage valves there is no S option.
Bore size 16 20 25 32 40 50 63 16 20 25 32 40 50 53 Recommended length Part No.
Bore size MB, CA2 series Pressure 0.5 MPa Load factor 50% Stroke 500 mm CM2 series Pressure 0.5 MPa Load factor 50% Stroke 300 mm CJ2 series Pressure 0.5 MPa Load factor 50% Stroke 60 mm Average speed (mm/s) Series 6 10 16 20 25 32 40 40 50 63 80 100 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation VQC1101 800 700 600 500 400 300 200 100 0 VQC2101 It
(Valve) SYJ5000-21-1A 1 pc. (Blanking plate assembly) SS5YJ5-43-03-C4 1 pc. (Manifold base) SYJ5140-5LZ 1 pc. (Valve) SYJ5240-5LZ 1 pc. (Valve) SYJ5000-21-1A 1 pc. (Blanking plate assembly) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
50 5000 mm 3 M With lead wire [115 VAC 50/60 Hz] M plug MN Without lead wire 220 VAC 50/60 Hz connector 4 MO Without connector [230 VAC 50/60 Hz] W0 Without connector cable M8 connector For type W, DC voltage is only available.
SV3000 In case of mixed specification (M), indicate separately on a manifold specification sheet.
lo switches Bore sizel E--6,"'"-l IE ro.m I IE re '. 1 Port location on head cover stroke (l00ihs o Standard 50, 100, 150,200 50, 100, 150, 200, 300.400, 500,600 50, 100, 150. 200,300,400, 500,600,700,400 Doub e actino Sinole aclino sorinq relurn Sinale aclinq sprinq extend Se Caralog N301 ior slandard stroke Lenglhs on lypes otherrhan single rod 'lnrermedate shkes can b nanufacrured upon
K Note 2) Negative common N Note 3) Coil voltage CE-compliant External pilot R Note 3) Note 5) 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Note 1) Refer to page 381 for power consumption of AC type.
Applicable cable O.D. 3.5 to 7 Station n L1 L2 3 80 68 Station 20 403 391 6 137 125 8 175 163 10 213 201 Station 2 61 49 4 99 87 5 118 106 7 156 144 9 194 182 11 232 220 12 251 239 13 270 258 14 289 277 15 308 296 16 327 315 17 346 334 18 365 353 19 384 372 4-4-50 3 Port Pilot Operated Solenoid Valve Rubber Seal Series SYJ700 N7 N9 C6 C8 [ ] for AC Type 42R Manifold: Side Ported/SS3YJ7-42RStations
A 1A () (+) SOL. B 1B () (+) Station 1 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A SOL. A 2A () (+) SOL. B 2B () (+) Station 2 SOL. A 3A () (+) 1.
220 VAC 50/60 Hz [230 VAC 50/60 Hz] 4 For type W, only DC voltage is available.
Rated voltage 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] 220 VAC 50/60 Hz [230 VAC 50/60 Hz] Electrical entry G H L LN LO M MN MO W0 Grommet (300 mm lead wire) Grommet (600 mm lead wire) With lead wire Without lead wire Without connector With lead wire Without lead wire Without connector Without connector cable Electrical
Coil rated voltage VP7 1 2 3 4 5 6 100V AC (50/60Hz) 200V AC (50/60Hz) 110V AC (50/60Hz) 220V AC (50/60Hz) 24V DC 12V DC VP4 VQ VQ4 Wiring Specifications VQZ The lead wires are connected to the valve as shown below. Connect each to the power supply side.
A 1A () (+) SOL. B 1B () (+) Station 1 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A SOL. A 2A () (+) SOL. B 2B () (+) Station 2 SOL. A 3A () (+) 1.
/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Note 1) Refer to page 522 for power consumption of AC type.
/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Note 1) Refer to page 522 for power consumption of AC type.
121538-1A 121538-1A-S1 [IS400-1 (Float switch only)] 121538-1A-S2 [IS400-2 (Float switch only)] 1000 cm3 tank 121538-1A-S1 IS400-1 Metal bowl with level gauge 121538-1A-S2 IS400-2 Note) Bowl O-ring (or seal) is included for the AL20 to AL60.