G M3 x 0.5 (VQZ2000) M5 x 0.8 (VQZ3000) Note 1) 3(R2), 5(R1) port of VQZ2000 is only G 1/16.
Note) Fixed unit: For vacuum/Low pressure: kPA For positive pressure: MPa Lead wire with connector Lead wire length: 2 m With mounting screws (M3 x 5L: 2 pcs.) With M3 x 8L (2 pcs.)
Applicable auto switch Reed switch Solid state switch Bore size (mm) D-F7, D-J79 D-F7V, D-J79C D-F7W, D-J79W D-F7WV, D-F79F D-F7NTL D-F7BAL/F7BAVL D-A7, D-A80 D-A7H, D-A80H D-A73C, D-A80C D-A79W Auto switch mounting screw (M3 x 0.5 x 6.5l) Switch mounting nut BMU1-025 25, 32, 40, 50, 63 Switch mounting bracket Round head Phillips screw (M3 x 0.5 x 14l) Hexagon socket head cap screw (M3 x
Applicable auto switch Reed switch Solid state switch Bore size (mm) D-F7, D-J79 D-F7V, D-J79C D-F7W, D-J79W D-F7WV, D-F79F D-F7NTL D-F7BAL/F7BAVL D-A7, D-A80 D-A7H, D-A80H D-A73C, D-A80C D-A79W Auto switch mounting screw (M3 x 0.5 x 6.5l) Switch mounting nut BMU1-025 25, 32, 40, 50, 63 Switch mounting bracket Round head Phillips screw (M3 x 0.5 x 14l) Hexagon socket head cap screw (M3 x
VZ VS VFN 4-4-11 12 Series SYJ300 Manifold for Internal Pilot Type Type 20 Applicable solenoid valve SYJ312--M3 SYJ312M--M3 SYJ322--M3 SYJ322M--M3 How to Order A port M3 x 0.5 SS3YJ3 20 05 Stations Bracket Applicable blanking plate assembly SYJ300-10-1A 02 2 stations Nil Without bracket P R R port : : F With bracket M5 x 0.8 20 20 stations P port Note) For more than 10 stations, supply air
(mm) <M3, M5> <M3, M5> Weight (g) Note) Model L1 L2 L3 A M D 2-applicable tubing M3 x 0.5 KJY23-M3 KJY23-M5 KJY23-01S KJY04-M3 KJY04-M5 KJY04-01S KJY06-M5 KJY06-01S 2.8 3.2 7.4 3.1 3.5 7.7 4.5 7.5 Reference dimensions after R thread installation.
(mm) <M3, M5> <M3, M5> Weight (g) Note) Model L1 L2 L3 A M D 2-applicable tubing M3 x 0.5 KJY23-M3 KJY23-M5 KJY23-01S KJY04-M3 KJY04-M5 KJY04-01S KJY06-M5 KJY06-01S 2.8 3.2 7.4 3.1 3.5 7.7 4.5 7.5 Reference dimensions after R thread installation.
MLU ML1C DMounting of Auto Switch -X Except D-P5DWL D-P5DWL 20Data Auto switch mounting screw Hexagon socket head cap bolt With SW M3 x 0.5 x 5l M3 x 0.5 x 6l Auto switch Switch mounting bracket With SW, M3 x 0.5 x 14l Round head Phillips screw 8 x 3.3 x t0.8 Flat washer Auto switch Auto switch mounting nut Auto switch mounting nut Tightening torque of auto switch mounting screws should
Mounting with brackets Mount a bracket to the using two M3 x 5L mounting screws and install on piping with a hexagon socket cap screws. The switch can be installed horizontally depending on the installation location. Mounting screw M3 x 5L Atmospheric release port To a safe place with no water or dust The tightening torque for bracket mounting screw should be 0.98Nm or less.
Note Lead wire length: 2m With mounting screws (M3 x 5L: 2 pcs.)
Piping thread type : When F is selected, G thread adapter set will be added.
44[lq I lrars wurh:8 ,t ic I Appl|cable lube o D oP Applicable lube O.D oP " l " l ' l ' l E f F f e f n l e ^ | o L I r E t #l#ffiJ'xl,LI v ZPRlOB 1 0 1 6 25133.! 50 20 71 25 76 13.8 5.5 ZPRtSB 18 527 sB6.'52.!
44[lq I lrars wurh:8 ,t ic I Appl|cable lube o D oP Applicable lube O.D oP " l " l ' l ' l E f F f e f n l e ^ | o L I r E t #l#ffiJ'xl,LI v ZPRlOB 1 0 1 6 25133.! 50 20 71 25 76 13.8 5.5 ZPRtSB 18 527 sB6.'52.!
Mounting with brackets Mount a bracket to the using two M3 x 5L mounting screws and install on piping with a hexagon socket cap screws. The switch can be installed horizontally depending on the installation location. Mounting screw M3 x 5L Atmospheric release port To a safe place with no water or dust The tightening torque for bracket mounting screw should be 0.98 Nm or less.
Auto Switch Mounting Except for D-P5DWL D-P5DWL Auto switch mounting screw Hexagon socket head cap bolt With SW M3 x 0.5 x 5l M3 x 0.5 x 6l Auto switch Switch mounting bracket With SW, M3 x 0.5 x 14l Round head Phillips screw 8 x 3.3 x t0.8 Flat washer Auto switch Auto switch mounting nut Auto switch mounting nut Tightening torque of auto switch mounting screws should be 0.5 to 0.7Nm.
M3 female -M3 male M-3UL For soft nylon tube. Barb elbow P. 92 3.18/2.18 Body rotates at 360 around the stud axis. Nipple M-5ALU-3 Fitting to workpiece and fitting to fitting connection. P. 90 For polyurethane tube. 3.18/2 M3 Universal tee M5 male -M5 male M-5N Body rotates at 360 around the stud axis. M3 female -M3 female -M3 male For soft nylon and polyurethane tube.
VF VFR How to Order Valve Manifold Assembly (Example) VP7 VP4 VQZ2150-5L VQZ2250-5L VQ U side 2 3 4 5 VQZ2350-5L VQ4 VV5QZ2505C6C1 set (C kit 5 stations manifold base) VVQZ200010A-51 set (Blank plate assembly) VQZ21505L 1 set (Valve P/N single solenoid) VQZ22505L 2 set (Valve P/N double solenoid) VQZ23505L 1 set (Valve P/N 3 position) VQZ D side 1 VQD VZS Prefix mark to valves etc. to
( Body Ported Type 2 Position Single : NVJA3120-M3(-F) 2 Position Double : NVJA322O-M3(-F) M3x0.5 2 po.ts (Piot r 0.07(1.8)Dia 2 Mounting hotes 0.13(3.2) Dia 2 Mounting holes \. I f---a I \ -"j f!'-ll L?