1 8 Rc 1 8 Rc 1 4 Rc 1 4 Rc 3 8 Rc 3 8 ZH05DS-01-01-01 ZH05DL-01-01-01 ZH07DS-01-01-01 ZH07DL-01-01-01 ZH10DS-01-01-01 ZH10DL-01-01-01 ZH13DS-01-02-02 ZH13DL-01-02-02 ZH15DS-02-03-03 ZH15DL-02-03-03 12 31.5 28.5 7.8 17 24 12 31.5 28.5 17 24 12 31.5 29.5 17 24 12 31.5 29.5 17 24 14 33.5 33 20 28 14 33.5 33 20 28 17 36.5 38.5 22 30 17 36.5 38.5 22 30 7.8 7.8 7.8 9.6 9.6 10.7 10.7 Rc 1 8 Rc
R2 P Manual override 8.5 34 63.8 13.8 (Light/surge voltage suppressor) 1/4, 1/8 (P, A, B port) 57.5 [64.5] + 42.1 25.5 20 12 22 22 11.5 18 1/4 (R1, R2 port) 31.5 34 63 L plug connector (L): 10-SYJ7 43-L3 4 5 01 02 M plug connector (M): 10-SYJ7 43-M3 4 5 01 02 DIN terminal (D, Y): 10-SYJ7 43D Y3 4 5 01 02 M8 connector (WO): 10-SYJ7 43-WO3 4 5 01 02 Applicable cable O.D. 3.5 to 7 141.8 [146.2
DIN terminal (D): SYJ7140-D01 02 M8 connector (WO): SYJ7140-WO01 02 L plug connector (L): SYJ7140-L01 02 Applicable cable O.D. 3.5 to 7 Approx. 300 (Lead wire length) 91 104.2 Max. .10 57.5 [64.5] 83.5 72.2 42.1 62 M8 x 1 57.1 44.5 (Lead wire length) Approx. 300 68.6 [75.6] 20 20 20 20 Pg7 95.1 [97.3] 85.3 [87.5] 94.2 86.8 80.3 22 22 22 22 64.3 63 63 63 63 22 22 22 22 31.5 31.5 31.5 31.5
X Port size) Speed controller System figure System Solenoid valve SYJ7l40-01 Rc(PT)1/8 (S = 12.6mm2) AN110-01 (S = 35mm2) 4 X 1/8 AS2301F-01-04 A 02 03 AS3301F-06 6 X 1/4 B q 02 03 AS3301F-08 SYJ7l40-02 Rc(PT)1/4 (S = 12.6mm2) 8 X 1/4 C AN200-02 (S = 35mm2) 02 03 AS3301F-10 10 X 1/4 D 12 X 1/4 12 X 1/2 AS4001F-12 w E 1.2-53 Series SYJ7000 How to Order Light and surge voltage suppressor
Nil Applicable blanking plate assembly SYJ300-10-2A 02 2 stations Pilot valve is on the A port side.
Stations S42R Type Coil is located on same side as the A port. 2 stations 02 Coil is located on same side as the A port. S ... ...
Q CE-compliant Nil 02 2 stations Nil Rc P R Pilot valve is on the A port side.
AC110V 110V SY100-61-2-03 V111(G,H,L,M,W)V115-Y(DIN) AC220V 220V SY100-61-2-04 Y DIN SY100-82-1 DC24V 24VN SY100-82-3-05 DC12V 12VN SY100-82-3-06 AC100V 100VN SY100-82-2-01 () AC200V 200VN SY100-82-2-02 AC110V(AC115V) 110VN SY100-82-2-03 AC220V(AC230V) 220VN SY100-82-2-04 AC DC LED R NL R: 12 No.SYJ300-OMU0003 SYJ Series Assy M8 Ass'y M8IP65() Ass'yV100-49-1NECA4202 IEC60947
List part numbers of the installed valve and option in required station location separately under manifold part number. 4-2-7 8 Series V100 Common SUP/Common EXH Type S41 How to Order Applicable solenoid valve Note) VV100 S41 05 M5 V114V114AV124V124AStations 2 port size 02 M5 M5 x 0.8 2 stations 2 Applicable blank plate assembly V100-77-1A 1 20 20 stations 3 2 1 port M5 x 0.8 3 port M5 x
(Example) 2000mm lead wire length Cover Groove Pin 300mm 600mm 1000mm 1500mm 2000mm 2500mm 3000mm 5000mm Lever 6 10 15 20 25 30 50 DC indicator Socket DXT170-71-1 For DC SY114-5LOZ SY100-30-4A-20 For AC SY114-1LOZ SY100-30-1A-20 Connector Hook Lead wire 10 World Wide Support... Europe ENGLAND SMC Pneumatics (U.K.) Ltd.
Function: 3 (3 Position Closed Center), Piping: 4 (Base Mounted), Exhaust: 0 (Individual), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: LO (L Plug w/o Connector), Surge Suppressor: Z (Light & Surge Suppressor)
Type: Solenoid Valves, Application: Unit for Manifold Mounting, Mounting Orientation: Manifold Base, Voltage: DC24V, Specification: Standard / Lubrication Free, Valve Type: 5-Port Valve, Actuation: -, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 3-Position Closed Center, Pipe Port Type: -, Port Size: -, Connecting Tube Diameter: -, Pressure Rating(MPa): 0.15 to 0.7
Function: 3 (3 Position Closed Center), Piping: 4 (Base Mounted), Exhaust: 0 (Individual), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: LO (L Plug w/o Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8)
Function: 3 (3 Position Closed Center), Piping: 4 (Base Mounted), Exhaust: 0 (Individual), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: LO (L Plug w/o Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: T (NPTF)
Function: 3 (3 Position Closed Center), Piping: 4 (Base Mounted), Exhaust: 0 (Individual), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: LO (L Plug w/o Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: N (NPT)
Function: 3 Position Closed Center, Piping: Base Mounted, Exhaust: Individual, Specifications: Standard, Voltage: 24VDC, Lead Wire: L Plug w/o Connector, Surge Suppressor: Light & Surge Suppressor, Manual Override: Non-locking Push Style, Port Size: Base Mounted w/Sub-plate 1/8, Body Ported 1/8, Thread: -, Option: -, CE Compliant: -
Function: 3 Position Closed Center, Piping: Base Mounted, Exhaust: Individual, Specifications: Standard, Voltage: 24VDC, Lead Wire: L Plug w/o Connector, Surge Suppressor: Light & Surge Suppressor, Manual Override: Non-locking Push Style, Port Size: Base Mounted w/Sub-plate 1/8, Body Ported 1/8, Thread: NPTF, Option: -, CE Compliant: -
Function: 3 Position Closed Center, Piping: Base Mounted, Exhaust: Individual, Specifications: Standard, Voltage: 24VDC, Lead Wire: L Plug w/o Connector, Surge Suppressor: Light & Surge Suppressor, Manual Override: Non-locking Push Style, Port Size: Base Mounted w/Sub-plate 1/8, Body Ported 1/8, Thread: NPT, Option: -, CE Compliant: -