SMC Corporation of America
Elite Part Number Search
Search Results "TMH-08"

A (2) AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 4 8 10.4 22.2 17 27 7 7 12.2 28.8 26 M5 x 0.8 9.6 25.2 22.4 6 12.8 23.2 18.5 8 8 28 (12.2) (28.8) (26) 4 10.4 24.3 17 17 17 31.4 13.4 35.5 30.5 6 R 1/8 12 14.2 32.4 27.4 12.8

M Weight (g) AS AS221F-U01-23 AS221F-U01-04 AS221F-U01-06 AS221F-U01-08 AS221F-U01-10 AS221F-U02-04 AS221F-U02-06 AS221F-U02-08 AS221F-U02-10 AS321F-U02-06 AS321F-U02-08 AS321F-U02-10 AS321F-U02-12 AS321F-U03-06 AS321F-U03-08 AS321F-U03-10 AS321F-U03-12 AS421F-U04-10 AS421F-U04-12 3.2 4 6 8 10 4 6 8 10 6 8 10 12 6 8 10 12 10 12 7.8 8.9 11.0 15.2 18.5 8.9 11.0 15.2 18.5 11.0 15.2 18.5 20.9

TMH Nil Option ASD None With seal Electroless nickel plated S N AS Type 1 If more than one option is required, write option part numbers in the order of S, N. 2 M3, M5, and U10/32 are not available with seals. Elbow Universal 2 3 AS-FE KE AS-FG Control type Applicable tubing O.D.

ASR ASQ KE TMH Air source Warning 1.

Speed Controller with One-touch Fittings In-line Type/Panel Mount Type AS 1F-3 Series RoHS Panel mount thickness: 3.5 mm at the maximum AS-F AS-F Model TMH TMH Easy installation and removal Applicable tubing O.D.

PE 08 Proximity dog ON Proximity dog (DOG) OFF ON Rough mat ch (CPO) OFF ON Travel completion (MEND) OFF ON Home position return completion (ZP) OFF Note 1. External input signal detection delays by the input filter setting time of parameter No. PD19.

Table 5.10 Selectable input devices Setting Input device (Note 1) value P S T 02 SON SON SON 03 RES RES RES 04 PC PC 05 TL TL 06 CR 07 ST1 RS2 08 ST2 RS1 09 TL1 TL1 0A LSP LSP LSP (Note 3) 0B LSN LSN LSN (Note 3) 0D CDP CDP 0E CLD 0F MECR 20 SP1 SP1 21 SP2 SP2 22 SP3 SP3 23 LOP (Note 2) LOP (Note 2) LOP (Note 2) 24 CM1 25 CM2 26 STAB2 STAB2 Note 1.

frequency you need. 00h _ x _ _ Notch depth selection 0: -40 dB 1: -14 dB 2: -8 dB 3: -4 dB 0h x _ _ _ For manufacturer setting 0h Table 5.4 Shaft resonance suppression filter setting frequency selection Setting value Frequency [Hz] Setting value Frequency [Hz] 00 Disabled 10 562 01 Disabled 11 529 02 4500 12 500 03 3000 13 473 04 2250 14 450 05 1800 15 428 06 1500 16 409 07 1285 17 391 08

PF _ _ ] 06: Parameter for manufacturer setting 07: Parameter for manufacturer setting 08: Parameter for manufacturer setting 09: Parameter for manufacturer setting 0A: Parameter for manufacturer setting 0B: [Pr. PL _ _ ] 0C: [Pr. PT _ _ ] 0E: [Pr.

Supplied regenerative resistors or regenerative option is used with the servo amplifier of 11k to 22kW. 01: FR-BU2-(H) FR-RC-(H) FR-CV-(H) 02: MR-RB032 03: MR-RB12 04: MR-RB32 05: MR-RB30 06: MR-RB50(Cooling fan is required) 08: MR-RB31 09: MR-RB51(Cooling fan is required) 80: MR-RB1H-4 81: MR-RB3M-4(Cooling fan is required) 82: MR-RB3G-4(Cooling fan is required) 83: MR-RB5G-4(Cooling fan

Supplied regenerative resistors or regenerative option is used with the servo amplifier of 11k to 22kW. 01: FR-BU2-(H) FR-RC-(H) FR-CV-(H) 02: MR-RB032 03: MR-RB12 04: MR-RB32 05: MR-RB30 06: MR-RB50(Cooling fan is required) 08: MR-RB31 09: MR-RB51(Cooling fan is required) 80: MR-RB1H-4 81: MR-RB3M-4(Cooling fan is required) 82: MR-RB3G-4(Cooling fan is required) 83: MR-RB5G-4(Cooling fan

Setting Control modes (Note 1) P S T 00 Always OFF Always OFF Always OFF 01 For manufacturer setting (Note 2) 02 RD RD RD 03 ALM ALM ALM 04 INP SA Always OFF 05 MBR MBR MBR 06 DB DB DB 07 TLC TLC VLC 08 WNG WNG WNG 09 BWNG BWNG BWNG 0A Always OFF SA SA 0B Always OFF Always OFF VLC 0C ZSP ZSP ZSP 0D For manufacturer setting (Note 2) 0E For manufacturer setting (Note 2) 0F CDPS Always Always

PD07 *DI3 3(CN6-3) CN6-3 PD06 000Ah 0 0 CN6-3 CN6-3 PD08 *DI4 4(CN6-4) CN6-4 PD06 000Bh 0 0 CN6-4 CN6-4 6 33 6 PD09 *DO1 1(CN6-14) CN6-14 0002h 0 0 CN6-14 CN6-14 () 00 OFF 02 RD 03 ALM 04 INP 05 MBR 06 DB 07 TLC 08 WNG 09 BWNG 0A SA 0C ZSP 0F CDPS 23 CPO 24 ZP 25 POT 26 PUS 27 MEND 38 1 PT0 39 2 PT1 3A 3 PT2 3B 4 PT3 3C 5 PT4 3D 6 PT5 3E 7 PT6 3F 8 PT7 .

(Default) Spare Rotary axis setting switch (SW1) Description Display 0 Axis No.1 01 1 Axis No.2 02 2 Axis No.3 03 3 Axis No.4 04 4 Axis No.5 05 5 Axis No.6 06 6 Axis No.7 07 Down 7 Axis No.8 08 (Be sure to set to the 8 Axis No.9 09 "Down" position.) 9 Axis No.10 10 A Axis No.11 11 B Axis No.12 12 C Axis No.13 13 D Axis No.14 14 E Axis No.15 15 F Axis No.16 16 3 36 4. STARTUP 4.

C 1. ##0016 ## 00 01 1 02 2 03 3 04 4 05 5 06 6 07 7 08 8 09 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 2. **No. 3.

(mm) Note) Type 04 06 08 10 12 4 6 8 10 12 Port size Elbow Universal 2 3 01 02 03 04 R 1/8 R 1/4 R 3/8 R 1/2 Made to Order (For details, refer to page 659.) Control type Note) For applicable tubing O.D. selection, refer to the Model.

ASD Model Meter-out type Rod and applicable tubing O.D. 4 6 8 10 Meter-in type AS1000P-04-04 AS2000P-04-04 AS2000P-06-06 AS2500P-06-06 AS3000P-08-08 AS3000P-10-10 AS1010P-04-04 AS2010P-04-04 AS2010P-06-06 AS2510P-06-06 AS3010P-08-08 AS3010P-10-10 AS AS-FE KE The lock nut provides identification.

ASD Model Meter-out type Rod and applicable tubing O.D. 4 10 8 6 Meter-in type AS1000P-04-04 AS2000P-04-04 AS2000P-06-06 AS2500P-06-06 AS3000P-08-08 AS3000P-10-10 AS1010P-04-04 AS2010P-04-04 AS2010P-06-06 AS2510P-06-06 AS3010P-08-08 AS3010P-10-10 AS AS-FE KE The lock nut provides identification.

Speed Controller with One-touch Fittings In-line Type/Panel Mount Type AS 1F-3 Series RoHS Panel mount thickness: 3.5 mm at the maximum AS-F AS-F Model TMH TMH Applicable tubing O.D.

(mm) Elbow type TMH 6 8 10 12 Tube swivels 360 AS121F-M5-W2 M5 ASD Application to inch size tubing Metric size 6, 8, 10, 12 AS221F-01-W2 R1/8 AS221F-02-W2 R1/4 AS AS321F-02-W2 R1/4 Maximum operating pressure 1 MPa max.