Valve specifications Pilot type Type of actuation Air Fluid Main valve Poppet Maximum operating pressure 0.7MPa Effective area 3mm Maximum vacuum pressure 84kPa Operating pressure 0.25 to 0.6MPa Supply pressure range 0.25 to 0.55MPa 5 to 50C Cv factor 0.17 Operating temperature range Polyethylene sintered body (30m) Electrical entry Plug connector Suction filter Maximum operating frequency 5Hz
Type of Actuation: 1 (Normally Closed), Flow Capacity: Standard, Coil Specification: T (0.1 W (with Power Saving Circuit)(24 VDC-12 VDC only)), Voltage: 5 (24VDC), Lead Wire: H (Grommet Lead Wire 0.6m), Surge Suppressor: Z (Light & Surge Suppressor)
Type: Solenoid Valves, Application: Unit for Manifold Mounting, Mounting Orientation: Manifold Base, Voltage: DC24V, Specification: Standard / Lubrication Free, Valve Type: 3-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Closed, Pipe Port Type: -, Port Size: -, Pressure Rating(MPa): 0~0.7, Driving Type: Linear
Discharge capability 1) Flow-rate characteristics PB1313A Flow-rate characteristics (5Hz) PB1313A5Hz 0.5 SUP=0.5MPa Discharge pressure (MPa) 0.4 SUP=0.4MPa MPa 0.3 SUP=0.3MPa 0.2 SUP=0.2MPa 0.1 0 0 200 400 600 800 1000 Discharge rate (mL/min) mL/min Caution -The above flow characteristic graph is for clean water (viscosity 1mPas, specific gravity 1.0).
Internal pilot: 1 to 5HZ and external pilot: 1 to 8Hz is reference. The charts on page 10 show the relation for the adjustment needle value and operation frequency. However, there is approx. 2Hz of variation depending on individuality. Operating conditions affect the operating frequency.
Display of frequency 1Hz 3Hz 5Hz 8Hz 10Hz 15Hz 20Hz 30Hz DC DC Default frequency setting is 30 Hz. Set the optimum frequency depending on the operating environment and installed distance. 4-4-4. Offset voltage adjustment mode Offset voltage is adjusted before shipment.
Type of valve actuation Air Fluid 0.2 to 0.5MPa Operating pressure range Internal pilot type 5 to 50C Ambient and fluid temperature 25ms or less Response time (for 0.5MPa) Note 1) 5Hz Maximum operating frequency Non-locking push type, Slotted locking type Manual operation With vacuum pressure gauge Pilot valve individual exhaust type, Main valve/Pilot valve common exhaust Pilot exhaust type
Type of Actuation: 1 (Normally Closed), Flow Capacity: Standard, Coil Specification: T (0.1 W (with Power Saving Circuit)(24 VDC-12 VDC only)), Voltage: 5 (24VDC), Lead Wire: LO (L Plug w/o Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: B (Locking Slotted), Port Size: M5 (With Sub-Plate)
Type of Actuation: 1 (Normally Closed), Flow Capacity: Standard, Coil Specification: T (0.1 W (with Power Saving Circuit)(24 VDC-12 VDC only)), Voltage: 5 (24VDC), Lead Wire: MN (M Plug Connector w/o Lead Wire), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-Locking Push, Port Size: M5 (With Sub-Plate)
Type of Actuation: 1 (Normally Closed), Flow Capacity: Standard, Coil Specification: T (0.1 W (with Power Saving Circuit)(24 VDC-12 VDC only)), Voltage: 6 (12VDC), Lead Wire: M (M Plug Connector w/Lead Wire 0.3m), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: B (Locking Slotted), Port Size: M5 (With Sub-Plate)
Type of Actuation: 1 (Normally Closed), Flow Capacity: Standard, Coil Specification: T (0.1 W (with Power Saving Circuit)(24 VDC-12 VDC only)), Voltage: 6 (12VDC), Lead Wire: L (L Plug Connector w/Lead Wire 0.3m), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: B (Locking Slotted), Port Size: M5 (With Sub-Plate)
Type of Actuation: 1 (Normally Closed), Flow Capacity: Standard, Coil Specification: T (0.1 W (with Power Saving Circuit)(24 VDC-12 VDC only)), Voltage: 6 (12VDC), Lead Wire: MO (M Plug w/o Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-Locking Push, Port Size: M5 (With Sub-Plate)
Type of Actuation: 1 (Normally Closed), Flow Capacity: Standard, Coil Specification: T (0.1 W (with Power Saving Circuit)(24 VDC-12 VDC only)), Voltage: 6 (12VDC), Lead Wire: H (Grommet Lead Wire 0.6m), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-Locking Push, Port Size: M5 (With Sub-Plate)
Type of Actuation: 1 (Normally Closed), Flow Capacity: Standard, Coil Specification: T (0.1 W (with Power Saving Circuit)(24 VDC-12 VDC only)), Voltage: 6 (12VDC), Lead Wire: MN (M Plug Connector w/o Lead Wire), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-Locking Push, Port Size: M5 (With Sub-Plate)
Type of Actuation: 1 (Normally Closed), Flow Capacity: Standard, Coil Specification: T (0.1 W (with Power Saving Circuit)(24 VDC-12 VDC only)), Voltage: 6 (12VDC), Lead Wire: LO (L Plug w/o Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: B (Locking Slotted), Port Size: M5 (With Sub-Plate)
Type of Actuation: 1 (Normally Closed), Flow Capacity: Standard, Coil Specification: T (0.1 W (with Power Saving Circuit)(24 VDC-12 VDC only)), Voltage: 6 (12VDC), Lead Wire: G (Grommet Lead Wire 0.3m), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: B (Locking Slotted), Port Size: M5 (With Sub-Plate)
Type of Actuation: 1 (Normally Closed), Flow Capacity: Standard, Coil Specification: T (0.1 W (with Power Saving Circuit)(24 VDC-12 VDC only)), Voltage: 5 (24VDC), Lead Wire: LN (L Plug Connector w/o Lead Wire), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-Locking Push, Port Size: M5 (With Sub-Plate)
Type of Actuation: 1 (Normally Closed), Flow Capacity: Standard, Coil Specification: T (0.1 W (with Power Saving Circuit)(24 VDC-12 VDC only)), Voltage: 5 (24VDC), Lead Wire: LO (L Plug w/o Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-Locking Push, Port Size: M5 (With Sub-Plate)
Type of Actuation: 1 (Normally Closed), Flow Capacity: Standard, Coil Specification: T (0.1 W (with Power Saving Circuit)(24 VDC-12 VDC only)), Voltage: 5 (24VDC), Lead Wire: L (L Plug Connector w/Lead Wire 0.3m), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: B (Locking Slotted), Port Size: M5 (With Sub-Plate)
Type of Actuation: 1 (Normally Closed), Flow Capacity: Standard, Coil Specification: T (0.1 W (with Power Saving Circuit)(24 VDC-12 VDC only)), Voltage: 5 (24VDC), Lead Wire: MO (M Plug w/o Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-Locking Push, Port Size: M5 (With Sub-Plate)