Screw-in type (6A to 50A) and the flange (32F to 50F) are standardized.
1 50F (10C) 68F (20C) 86F (30C) Standard model Set dew point (Normal operation) Accumulated running hours display Helps maintenance control of the dryer. Gives notice of the maintenance timing etc. 1. Energy saving operation (ECO LED is ON green): Dew point can be set manually between 50 to 86F(10 to 30C). 2. Normal operation (ECO LED is OFF): Dew point is fixed to 50F (10C).
Non plug-in type VV5FS3-10 VFS310-D VFS310-E
VFR2110-5D 5 sets (2 position single part no.) VFR2410-5D 1 set (3 position exhaust part no.) VVFS2000-R-01-2 1 set (Individual EXH spacer part no.) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
F 3 8 Option VV5FS4-10-061-03-A VFS4110-5D 1 4 The asterisk denotes the symbol for assembly.
VFR2110-5D 5 sets (2 position single part no.) VFR2410-5D 1 set (3 position exhaust part no.) VVFS2000-R-01-2 1 set (Individual EXH spacer part no.) VV5FR2-01T1-061-02 1 set (Manifold base part no.) VFR2100-5FZ 3 sets (2 position single part no.) VFR2200-5FZ 2 sets (2 position double part no.) VVFS2000-10A 1 set (Blanking plate assembly part no.)
New Products Guide 1 Directional Control Valves Actuators Vacuum Equipment CAT.E00-6A INDEX New Products Guide 1 Directional Control Valves 5 Port Solenoid Valve Fieldbus System (For Input/Output) 2/3 Port Mechanical Valve Series SY3000/5000/7000 Series EX600 Series VM100/200 P .6 P .264 P .322 Actuators Foot Pedal Type 5 Port Mechanical Valve XT34-60/67 Air Cylinder Air Cylinder Series CJ2
CDQSXB20-30D CDQSXB12-5D 60 CQ-M5 x 60 L 30 CQ-M3 x 30 L 35D 10D 65 x 65 L 35 x 35 L 40D 15D 70 x 70 L 40 x 40 L 6.5 Example) CQ-M3x30 L 4 pcs. 6.5 45D 20D 75 x 75 L 45 x 45 L REA 50D 25D 80 x 80 L 50 x 50 L CDQSXB25-5D 30D Mounting bolt 40 55 x 55 L CQ-M5 x 40 L REB 10D CDQSXB16-5D 45 30 x 45 L CQ-M3 x 30 L 15D 10D 50 35 x 50 L x 35 L REC 20D 15D 55 40 x 55 L x 40 L 6.5 CY 25D 20D 60 45
Note 1) In the case of ZCUKR16-5D: 14.5 mm.
Description VNC1 -6A, 8A, 10A VNC2 -10A, 15A VNC3 -20A VNC4 -25A VNC5 -32A, 32F VNC6 -40A, 40F VNC7 -50A, 50F No.
Note 1) Use a 15% ethylene glycol aqueous solution if operating in a place where the ambient temperature and/or circulating fluid temperature is 50F (10C) or less. Note 2) Use fluid in condition below as the circulating fluid.
The table below applies to the air pressure dew point (at 100 psi (0.7 MPa)) 50F (10C). In cases where other dew points are needed, please refer to page 2 (Model Selection) of this catalog.
Cooling Capacity
Refrigerant AFF AM UL certified product Improved corrosion resistance with the use of stainless steel, plate type heat exchanger (IDFB4E to 75E) AMD Power supply voltage: Single-phase 115 VAC (60 Hz) 230 VAC (60 Hz) Three-phase 460 VAC (60 Hz) AMH AME Air flow capacity SCFM (m3/h [ANR]) Series Rated inlet condition Port size Outlet air pressure dew point Note) AMF 37F(2.8C) 45F(7.2C) 50F(
Description VNC1 -6A, 8A, 10A VNC2 -10A, 15A VNC3 -20A VNC4 -25A VNC5 -32A, 32F VNC6 -40A, 40F VNC7 -50A, 50F No.
Mounting bolt Mounting bolt diagram C D D Model C Mounting bolt Model C D Mounting bolt M5 x 55l x 60l x 65l x 70l x 75l x 80l x 85l x 90l x 95l x 100l M8 x 95l x 100l x 105l x 110l x 115l x 120l x 125l x 130l x 135l x 160l x 185l 5D (M) CHQB63 10D (M) CH QB20 55 60 65 70 75 80 85 90 95 100 70 75 80 85 90 95 100 105 110 115 140 165 75 80 85 90 95 100 105 110 115 120 145 170 90 95 100 105
(M) x 95L 95 x 135L 135 -50D (M) -75D (M) x 100L 100 x 160L 160 CHQ CHmQB32-5D (M) -100D (M) CHmQB80-10D (M) M5 x 70L 70 x 185L 185 -10D (M) M10 x 100L x 75L 75 100 CHKm -15D (M) -15D (M) x 80L 80 105 x 105L -20D (M) -20D (M) x 85L 85 110 x 110L CHN -25D (M) -25D (M) x 90L 90 115 x 115L -30D (M) -30D (M) x 95L 95 120 x 120L CHM 7 -35D (M) -35D (M) x 100L 100 14.5 125 x 125L CHSm -40D (M)
CHQ CHQ C D CHK Mounting Bolts CHQWB20-5D (M) C D C D Model Mounting bolt part no. Model Mounting bolt part no.
-25A VND50D-32A VND50D-32F VND60D-40A VND60D-40F VND70D-50A VND70D-50F 1 8 1 4 26 28 31 120 130 240 380 7 0.3 3 8 15 0.6 1 2 3 4 20 0.9 1.4 2.3 5.5 3.6 7.2 5.7 10.8 25 1 VC 1 4 1 440 32 32 1 2 1 VDW 920 40 40 2 VQ 1500 50 50 Note) The companion flange is JIS B 2210 10K (standard) or its equivalent.
For Use in North, Central and South America Refrigerated Air Dryer (UL, CSA Standards) Applicable for the high-temperature environments Ambient temperature : Max. 113F (45C) Inlet air temperature : Max. 149F (65C) Air flow capacity * IDFB90-23, Dew point of 50F (10C) 459 SCFM (780 m3/h) (13% increase compared to the current model) Power supply voltage Single-phase 230 VAC (60 Hz) Single-phase