SMC Corporation of America
Elite Part Number Search
Search Results "VP542R-3D1-03A"

Pressure gauge or pressure convertor Thermometer Differential pressure gauge or differential pressure converter Pressure control equipment d1 d3 3d1 3d3 d2 Flow control valve Shut off valve Filter Flow meter Air supply 10d3 10d1 10d2 3d1 3d2 Pipe for measuring temperature Equipment for test Pipe for measuring pressure in the downstream side Pipe for measuring pressure in the upstream side

Pressure gauge or pressure convertor Thermometer Differential pressure gauge or differential pressure converter d1 Pressure control equipment d3 3d1 Flow control valve 3d3 d2 Flow meter Shut off valve Filter Air supply 3d2 10d2 3d1 10d1 10d3 Equipment for test Pipe for measuring temperature Pipe for measuring pressure in the downstream side Pipe for measuring pressure in the upstream side

Pressure gauge or pressure convertor Thermometer Differential pressure gauge or differential pressure converter Pressure control equipment d1 d3 3d1 3d3 Flow control valve d2 Shut off valve Air supply Filter Flow meter 10d3 10d1 10d2 3d1 3d2 Pipe for measuring temperature Equipment for test Pipe for measuring pressure in the downstream side Pipe for measuring pressure in the upstream side

Pressure gauge or pressure convertor Thermometer Differential pressure gauge or differential pressure converter Pressure control equipment d1 d3 3d1 3d3 Flow control valve d2 Shut off valve Air supply Filter Flow meter 10d3 10d1 10d2 3d1 3d2 Pipe for measuring temperature Equipment for test Pipe for measuring pressure in the downstream side Pipe for measuring pressure in the upstream side

Pressure gauge or pressure converter Thermometer Differential pressure gauge or differential pressure converter Pressure control equipment d1 d3 3d1 Flow control valve 3d3 d2 Air Filter Shut off valve Flow meter 3d2 10d2 3d1 10d1 10d3 supply Pipe for measuring temperature Pipe for measuring pressure on the upstream side Test equipment Pipe for measuring pressure on the downstream side Fig

Pressure gauge or pressure convertor Thermometer Differential pressure gauge or differential pressure converter d1 Pressure control d3 3d1 equipment Flow control 3d3 valve d2 Filter Air Flow meter Shut off 3d2 10d2 3d1 10d1 10d3 supply valve Pipe for measuring Equipment temperature for test Pipe for Pipe for measuring measuring pressure in the pressure in the downstream side upstream side

Series: 542 (VP500), Pilot Type: R (External Pilot), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115VAC), 50/60Hz], Electrical Entry: D (DIN Terminal w/Connector), Light & Surge Suppressor: w/o Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: 02 (1/4), Thread Type: Rc, Actuation Type: A (N.C., Normally Closed)

Series: 542 (VP500), Pilot Type: R (External Pilot), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115VAC), 50/60Hz], Electrical Entry: D (DIN Terminal w/Connector), Light & Surge Suppressor: w/o Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: 02 (1/4), Thread Type: N (NPT), Actuation Type: A (N.C., Normally Closed

Series: VP500, Pilot Type: External Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115VAC), 50/60Hz], Electrical Entry: DIN Terminal w/Connector, Light & Surge Suppressor: w/o Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: 1/4, Thread Type: NPT, Actuation Type: N.C., Normally Closed, Bracket: -, Made to Order

Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: AC110V, Specification: Standard / Drip-Proof / Lubrication Free / Low Current, Valve Type: 3-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Closed, Pipe Port Type: [Rc (R)] Rc, Port Size: 1/4, Pressure Rating(MPa): -0.1~0.7

VHS20-01A VHS30-02A Pressure relief 3 port valve Note5) VHS40-06A Attachment VHS20-02A VHS30-03A VHS40-04A E300-04-A E300-03-A E300-02-A E400-02-A E200-01-A E400-04-A E400-03-A Piping adapter Note5) E100-M5-A E200-02-A E500-06-A E200-03-A E400-06-A IS10E-4002-A IS10E-3002-A IS10E-2001-A IS10E-4003-A Pressure switch with Note5) IS10E-2002-A IS10E-3003-A piping adapter IS10E-4004-A IS10E

VHS40-06A Attachment VHS20-02A VHS30-03A VHS50-10A VHS40-04A E400-02-A E200-01-A E300-02-A E400-03-A E600-06-A Piping adapter Note6) E100-M5-A E200-02-A E300-03-A E500-06-A E400-04-A E600-10-A E200-03-A E300-04-A E400-06-A IS10E-4002-A IS10E-2001-A IS10E-3002-A Pressure switch with Note6) IS10E-4003-A IS10E-2002-A IS10E-3003-A piping adapter IS10E-4004-A IS10E-2003-A IS10E-3004-A IS10E

VH*-OMQ0023-C PRODUCT NAME Pressure Relief 3 Port Valve With Locking Holes MODEL / Series / Product Number VHS20-(F,N)01~02A,B(-B,S)(-K,R,Z) VHS30-(F,N)02~03A,B(-B,S)(-K,R,Z) VHS40-(F,N)02~04A,B(-B,S)(-K,R,Z) VHS40-(F,N)06A,B(-B,S)(-K,R,Z) VHS50-(F,N)06~10A,B(-B,S)(-K,R,Z) VHS2510-(F,N)01~02A,B(-B,S)(-K,R,Z) VHS3510-(F,N)02~03A,B(-B,S)(-K,R,Z) VHS4510-(F,N)02~04A,B(-B,S)(-K,R,Z) VHS4510-(

M5 x 0.8 9 9 26.5 25.4 23.5 22.4 13.3 5/32" 8.2 10-32 UNF AS12;1F-U10/32-03A AS12;1F-M5-07A 1/4" 11.2 18.6 23.4 16.5 6 AS12;1F-U10/32-07A Note 1) Reference dimensions Note 2) Reference dimensions after installation of thread 5 Series AS Thread type: R, NPT Dimensions Seal method: Sealant Thread type: R, NPT D3 Applicable tubing O.D. d D1 A L4 L3 M T L1 H L2 (Width across flats) Metric size


Ex. 1) For the VS3135-02*: VP542K-*G1-02A-F For the VS3135-03*: VP542K-*G1-03A-F
Ex. 2) For the VS3145-04*: VP742K-*G1-04A-F
If you are using the product for air blow, as a selector valve, or at a pressure of 0.2 MPa or lower, consider using an external pilot type valve (VP542RK-*G1-02A-F, VP542RK-*G1-03A-F, or VP742RK-*G1-04A-F).

Series: 542 (VP500), Pilot Type: R (External Pilot), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 1 (100VAC, 50/60Hz), Electrical Entry: D (DIN Terminal w/Connector), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 03 (3/8), Thread Type: Rc, Actuation Type: A (N.C., Normally Closed)

Series: 542 (VP500), Pilot Type: R (External Pilot), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115VAC), 50/60Hz], Electrical Entry: D (DIN Terminal w/Connector), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 03 (3/8), Thread Type: Rc, Actuation Type: A (N.C., Normally Closed)

Series: 542 (VP500), Pilot Type: R (External Pilot), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Electrical Entry: LO (L-type Plug Connector w/o Connector), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: E (Push-turn Locking Lever Type), Port Size: 03 (3/8), Thread Type: Rc, Actuation Type: A (N.C., Normally Closed

Series: 542 (VP500), Pilot Type: R (External Pilot), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Electrical Entry: DO (DIN Terminal w/o Connector), Light & Surge Suppressor: w/o Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: 03 (3/8), Thread Type: Rc, Actuation Type: A (N.C., Normally Closed)

Series: 542 (VP500), Pilot Type: R (External Pilot), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Electrical Entry: LO (L-type Plug Connector w/o Connector), Light & Surge Suppressor: U (Light & Surge Suppressor, Non-polar), Manual Override: Non-locking Push Type, Port Size: 03 (3/8), Thread Type: Rc, Actuation Type: A (N.C., Normally Closed