entry L plug connector D DO With connector Without connector DIN terminal 3 Note) Do not replace V111 (G, H, L, M, W) to V115 (DIN terminal) and vice versa when replacing pilot valve assembly only.
(Blank plate ass'y) VQ SS3YJ5-41R-03-C6 .1 pc. (Manifold base) SYJ514R-5G .2 pcs. (Valve) SYJ500-10-3A . 1 pc.
Example: SS3YJ5-20-03 .1 set (Manifold base) SYJ512-5LZ-M5.2 sets (Valve) SYJ500-10-1A.1 set (Blanking plate assembly) SS3YJ5-41R-03-C6 . 1 set (Manifold base) SYJ514R-5G.2 sets (Valve) SYJ500-10-3A .1 set (Blanking plate assembly) The asterisk denotes the symbol for assembly.
0.57 0.37 0.45 0.55 0.36 0.50 0.51 0.50 0.38 0.46 2.3 2.0 2.1 2.3 2.1 2.1 2.5 2.2 2.2 2.2 0.26 0.25 0.25 0.26 0.24 0.20 0.23 0.30 0.23 0.26 0.55 0.49 0.51 0.54 0.50 0.50 0.59 0.55 0.52 0.53 1/8 1/8 1/8 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/8 C6 C8 1/8 C6 C8 1/8 1/8 C6 C8 SS5YJ7-20 Body ported SYJ72 for internal pilot SS5YJ7-21 SS5YJ7-40 SS5YJ7-41 SS5YJ7-42-C6 SS5YJ7-42-C8 Base mounted SYJ74 for
Example: SS3YJ5-20-03 .1 set (Manifold base) SYJ512-5LZ-M5.2 sets (Valve) SYJ500-10-1A.1 set (Blanking plate assembly) SS3YJ5-41R-03-C6 . 1 set (Manifold base) SYJ514R-5G.2 sets (Valve) SYJ500-10-3A .1 set (Blanking plate assembly) The asterisk denotes the symbol for assembly.
) N7 N9 C6, C8, Directional Control Valves Air Grippers Modular F.
R C R C (44) G1/2 E A H 2-P Port size B (S) E G1/2 2-M Thread depth N D A H B 2-P Port size 2-M Thread depth N D L L K K N.O.
SX VK L C3 (3.2) C4 (4) C6 (6) M5 (M5 thread) VZ C6 (6) kit VF VFR N1 (1/8) N3 (5/32) N7 (1/4) N7 (1/4) VP7
0 1000 2000 3000 4000 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) ARBF5050-00-A ARBF3050-00-A ARBF4050-00-A 0.6 Inlet pressure 0.7 MPa Inlet pressure 0.7 MPa Inlet pressure 0.7 MPa 0.5 Outlet pressure (MPa) 0.4 0.3 0.2 0.1 0 1000 2000 3000 4000 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) 3-5-6 7 Series VFR2000/3000/4000/5000/6000 Caution
Porting specifications 4(A), 2(B) port Port size Applicable valve model Wiring Base model 1(P), 5(R1) 3 (R2) 4(A) 2(B) Stations Plug-in type VV5ZS2-51F VV5ZS2-51G 2 to 16 stations With D-sub connector With attachment plug lead wire Rc VZS250-FZ 1 8 Rc 1 8 Side Grommet L plug connector M plug connector K plug connector C4 VZS250G L M KZ Non plug-in type VV5ZS2-51 2 to 24 stations C6
(Stations 7 to 8) SS0752-08C S0712-5G-C4 S0722-5G-C4 S0732-5G-C4 S07A2-5G-C4 Body Ported Manifold Bar Base Voltage Symbol Type 5 24 VDC 6 12 VDC Note) The valve cannot be used as a standalone unit. Prefix the asterisk to the part numbers of the solenoid valve etc. Write sequentially from the 1st station on the D side.
Compact / Lightweight 2 Port Solenoid Valve VDW30/40-XF Series For Air/Water Compact / Lightweight resin body (PPS) IP65 RoHS Weight: 120 g (VDW30-XF) n t r e y l d a i 30 mm c r e i r c e s l t e e c c t b t i Power consumption e e o n d l a n .
O.D.: 4, 5/32" : 6, 1/4" (2.3) L plug connector (L): SYJ5120-L-M5(-F) M plug connector (M): SYJ5120-M-M5(-F) DIN terminal (D): SYJ5120-D-M5(-F) M8 connector (W0): SYJ5120-W0-M5(-F) Approx. 300 (Lead wire length) Applicable cable O.D. 3.5 to 7 82.1 Max. 10 60.9 28.1 [35.1] 53.4 12.7 42.1 32.6 M8 x 1 15.1 39.2 [46.2] Approx. 300 (Lead wire length) Pg7 73 [75.2] (2.3) 63.2 [65.4] 83 72.1 3
entry L plug connector D DO With connector Without connector DIN terminal 3 Note) Do not replace V111 (G, H, L, M, W) to V115 (DIN terminal) and vice versa when replacing pilot valve assembly only.
(Example) SS3YJ5-20-03 . 1 set (manifold base) SYJ512-5LZ-M5 . 2 sets (valve) SYJ500-10-1A . 1 set (blanking plate assembly) SS3YJ5-41R-03-C6 . 1 set (manifold base) SYJ514R-5G . 2 sets (valve) SYJ500-10-3A . 1 set (blanking plate assembly) The asterisk denotes the symbol for assembly.
Approx. 600 (Lead wire length) 31.5 [38.5] 70.6 [72.8] (Light/surge voltage suppressor) 2-3.2 (For mounting) 23.5 10.9 74.2 [76.4] + 28 25 16.1 21 31.5 [38.5] 18 10 (Bracket) 3.6 1/8 (P, R port) R P 28 8 1.6 (PE port) 14.5 16 L plug connector (L): SYJ72-L-01 (-F) M plug connector (M): SYJ72-M-01 (-F) DIN terminal (D): SYJ72-D-01 (-F) M8 connector (M0): SYJ72-W0-01 (-F) Approx. 300 (Lead wire
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard / Drip-Proof / Lubrication Free, Valve Type: 2-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Closed, Pipe Port Type: One-Touch Plumbing, Connecting Tube Diameter: Ø6, Pressure Rating(MPa):
Series: 2 (VQ21), Body Style: A (Single Unit), Coil Voltage: 5 (24VDC), Lead Wire: G (Grommet), Voltage Protection: None (Or w/Surge Suppressor in Case of AC Volts), Manual Override: None, Port Size: C6 (ø6 One-touch Fitting)