Load factor: ((Load weight x 9.8)/Theoretical force) x 100% System Components Solenoid valve System Silencer Speed controller SPG (Steel pipe) dia. x Length 10A x 1 m Series VFR4000 Rc 3/8 Series VFR4000 Rc 3/8 AS4000-03 (S = 21 mm2) AN300-03 (S = 60 mm2) A AS420-03 (S = 73 mm2) 10A x 1 m AN300-03 (S = 60 mm2) B 15A x 1 m Series VFR4000 Rc 1/2 AN400-04 (S = 90 mm2) AS420-04 (S = 97 mm2) C
95.5 77.3 43.5 20.6 12 0 VFS 60 42.7 15.7 1 VFR 11.5 1/8" PE. port 1/8" External pilot port M12 8-pin plug 27.9 33.5 37.5 45.2 VQ7 1/4", 3/8" C6, C8, C10, C12, N7, N9, N11 4(A), 2(B) port Note) The dimensions of the bottom ported type are common to all S kits.
Load factor: ((Load weight x 9.8)/Theoretical force) x 100% System Components VS4 System Solenoid valve Speed controller Silencer Tube bore x Length VQ7 Series VFS2000 AN110-01 (S = 35 mm2) AS3000-02 (S = 12 mm2) A T0604 x 1 m 1 8 Rc EVS Series VFS2000 AN110-01 (S = 35 mm2) AS4000-02 (S = 21 mm2) VFN B T1075 x 1 m 1 4 Rc Double Check Spacer/Specifications Can hold an intermediate cylinder
connectors, so switching from the F kit (D-sub connector) to the S kit (serial transmission) can be done simply by changing the kit section. 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 6 7 8 9 10 (Refer to the connector wiring diagram.)
C M S C C S M C S M NI NI IN IN OUT OUT B B 2 To CYL port To CYL port 4 P.960 P.961 P.962 P.974 Connector assembly SY3000-37-80AHousing (1 set: 8 pcs.)
(n) 7 stations (15 stations) New D-sub connector VQ7 Conventional D-sub connector (2) (1) Lead wire color Black Brown Red Orange Yellow Pink Blue Purple Gray White White Yellow Orange Yellow Pink Blue Purple Gray Orange Red Brown Pink Gray Black White 8 stations (Max. 16 stations) Terminal No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Dot marking None None None None
connectors, so switching from the F kit (D-sub connector) to the S kit (serial transmission) can be done simply by changing the kit section. 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 6 7 8 9 10 (Refer to the connector wiring diagram.)
-42-C6 VV5Z3-43 0.16 0.17 0.21 0.20 0.19 0.26 0.23 0.31 0.29 0.32 0.64 0.68 0.82 0.80 0.74 0.15 0.16 0.18 0.17 0.14 0.35 0.35 0.22 0.24 0.29 0.55 0.59 0.74 0.71 0.55 1/8 1/8 1/4 1/4 1/8 M5 x 0.8 M5 x 0.8 1/8 C6 C4 VZS VZ34 VFS Note) Value at manifold base mounted, 2 position single operating VS4 How to Order Manifold VQ7 Instruct by specifying the valves and blanking plate assembly to be
Round head combination screw VQ7 ( ) M3 x 8 With spring washer EVS Blanking plate VZ5000-68-1A VZ5000-68-1A VFN Manifold gasket Applicable Plug Assembly (D-sub connector cable assembly) Cable length 1.5 m 3 m 5 m 8 m Assembly part no.
FG 25ASize 32: NM2 Size: 63 LEC 4 x FA thread depth FB Motor mounting surface LEC S 2 x FA thread depth FB LEC SS-T LEC Y FD+0.3 +0.1 FD FC Motorless Motorless FC LAT FE FG FF FF FG FC LZ LC3F2 Dimensions [mm] Size Motor type FA FB FC FD FE FF FG M1 T1 M2 T2 PD PP NZ M4 x 0.7 7.5 46 30 3.7 11 42 M2.5 x 10 1.0 M3 x 8 0.63 8 7.5 NY M3 x 0.5 5.5 45 30 5 11 42 M2.5 x 10 1.0 M3 x 8 0.63 8 7.5
fitting Rc 1/4 Rc 3/8 G 1/4 G 3/8 A, B ports mixed 8 One-touch fitting 5/16" One-touch fitting SV1000 SV1000 3/8" One-touch fitting 10 One-touch fitting SV2000 SV2000 12 One-touch fitting 3/8" One-touch fitting SV3000 SV3000 3/8" One-touch fitting 12 One-touch fitting SV4000 NPT 3/8 SV4000 Rc 3/8 NPTF 3/8 G 3/8 In case of mixed specification (M), indicate separately on a manifold specification
fitting for 3/8" One-touch fitting for 5/16" One-touch fitting for 3/8" NPT 1/4 NPT 3/8 NPTF 1/4 NPTF 3/8 One-touch fitting for 5/16" SV1000 P, E port location One-touch fitting for 3/8" SV2000 U D B U side (2 to 10 stations) D side (2 to 10 stations) Both sides (2 to 20 stations) One-touch fitting for 3/8" SV3000 SUP/EXH block assembly specifications One-touch fitting for 3/8" Nil S R RS
Communication protocol DN1 DN1-X26 MJ1 CS1 CS2 SL1 SL2 UW1 UH1 DeviceNet Note 1) DeviceNet Note 1) CC-Link OMRON Corp.: CompoBus/S (16 outputs) OMRON Corp.: CompoBus/S (8 outputs) SUNX Corp.: S-LINK (16 outputs) SUNX Corp.: S-LINK (8 outputs) NKE Corp.: Uni-wire System NKE Corp.: Uni-wire H System Note 1) DN1s occupied points are 16 inputs and 16 outputs, while DN1-X26 has 0 inputs and 16
[Option] Conforms to ISO 15407-2 Standard Size 18 mm, 26 mm Plug-in Type 5 Port Solenoid Valve Series VS 8-2/VS 8-4 S R S R Series VS 8-4 S R Series VS 8-2 S R Conforms to ISO 15407-2 Standard S R S R ISO Standard: Interface conforming to 18 mm size (VS 8-2) and 26 mm size (VS 8-4) Accommodates IP65 enclosure.
-02-11(S)A 3/8" 15.9 17.4 23 41.2 26.1 62.5 15.6 46 (46) AS33l1FG-03-07(S)A 1/4" 3/8 19 11.2 12.9 16.6 20.2 36 21.4 50.1 42.3 40.7 37.1 35.5 13.3 32 (33) AS33l1FG-03-09(S)A 5/16" 13.2 37.1 23.5 52.2 14.2 33 (34) AS33l1FG-03-11(S)A 3/8" 15.9 17.4 23 41.2 26.1 54.8 15.6 37 (38) AS43l1FG-04-11(S)A 3/8" 1/2 24 (23.8) 15.9 17.4 18.8 25.6 46.4 (46.3) 26.1 61.2 50.8 49.2 43.7 42.1 15.6 58 (57) AS43l1FG
MECHATROLINK-II Command.8-4 8.1 Layers.8-4 8.2 Frame Structure.8-4 8.3 State Transition Diagram.8-5 8.4 Command and Response Timing.8-6 8.4.1 Command Data Execution Timing.8-6 8.4.2 Monitored Data Input Timing.8-6 8.4.3 Supporting the Transmission Cycle of 125 s.8-7 8.5 List of Commands.8-8 8.5.1 Command Types.8-8 8.5.2 Main Commands.8-8 8.5.3 Subcommands.8-10 8.5.4 Combinations of Main Commands
VP4 VZS Specifications VFS Main pressure External pilot pressure 100 kPa to 0.7 0.15 to 0.7 Pilot valve individual exhaust Operating pressure range (MPa) Pilot exhaust method VS4 VQ7 Dimensions VZ3000: 8 mm longer VZ5000: 8 mm longer EVS VFN JIS Symbol Body ported 2 position single 3 position closed center 2 position double 3 position exhaust center 3 position pressure center 3-3-85 Series
26.1 13.3 9 (9) AS221F-01-04(S)A 4 8.2 AS221F-01-06(S)A 6 10.4 10 (9) AS221F-01-08(S)A 8 13.2 22.4 29.5 14.2 11 (10) AS221F-01-10(S)A 10 15.9 25.3 32.4 15.6 12 (11) AS221F-02-23(S)A 3.2 1/8 13 (12.7) 7.2 20.9 30.2 (30.3) 22.6 36.6 35 31.1 29.5 13.3 18 (19) AS221F-02-04(S)A 4 8.2 AS221F-02-06(S)A 6 10.4 23.4 32.7 (32.8) AS221F-02-08(S)A 8 13.2 23.9 33.2 (33.3) 14.2 19 (20) AS221F-02-10(S)
stations Type VK334 Nil F N T Rc S Port size Type VK3140 G P port: Rc 1/8 1 8 01 Rc C6 6 cassette NPT R port: Rc 1/8 NPTF B port: Rc 1/8 A port: Rc 1/8 Common SUP/Individual EXH Type 21: Body ported (A, B port top ported) How to Order Applicable solenoid valve VK3120M5 VK312001 VK332M5 VK33201 A port: Rc 1/8, M5 x 0.8 VV5K3 21 05 A, B port: Rc 1/8, M5 x 0.8 VK3120 VK332 Thread type Valve
compatible 16 1 to 8 stations 16 stations SUNX Corporation: S-LINK System (16 outputs) compatible SUNX Corporation: S-LINK System (8 outputs) compatible 8 1 to 4 stations 8 stations D side Device Net, OMRON Corporation: CompoBus/D compatible 16 1 to 8 stations 16 stations OMRON Corporation: CompoBus/S (16 outputs) compatible OMRON Corporation: CompoBus/S (8 outputs) compatible 8 1 to 4 stations